CLEVELAND CLESK1427305

Cleveland SK1427305 Capacitor User Manual

Model: CLESK1427305 | 4700µF, 63VDC, 105°C

1. Introduzione

This manual provides essential information for the safe and effective use of the Cleveland SK1427305 Capacitor. This component is a genuine OEM replacement part designed for specific industrial electrical applications. It functions as an energy storage device, crucial for filtering, smoothing, and timing circuits. Please read this manual thoroughly before installation and operation.

2. Informazioni sulla sicurezza

Avvertimento: Electrical components can pose significant hazards if not handled correctly. Improper installation or use can result in electric shock, fire, or damage to equipment. Always adhere to the following safety guidelines:

3. Prodotto finitoview

The Cleveland SK1427305 is a high-quality electrolytic capacitor designed for robust performance in industrial settings. It features a cylindrical shape with screw terminals for secure connections. The capacitor is rated for 4700 microfarads (µF) capacitance and a maximum operating voltage of 63 VDC, with a temperature rating of 105°C.

Cleveland SK1427305 Capacitor with screw terminals and mounting screws

Figura 3.1: Cleveland SK1427305 Capacitor showing its blue cylindrical body, two screw terminals, and accompanying mounting screws.

Close-up of Cleveland SK1427305 Capacitor markings

Figura 3.2: Dettagliato view of the capacitor's side, displaying key specifications such as '4700 µF', '63 V', '105°C', and the 'POSITIVE' terminal indicator.

4. Configurazione e installazione

Proper installation is critical for the capacitor's performance and safety. Follow these steps carefully:

  1. Disconnessione dell'alimentazione: Ensure all power to the equipment is completely disconnected and verified before beginning installation.
  2. Discharge Existing Capacitors: If replacing an existing capacitor, ensure it is fully discharged before removal.
  3. Verifica le specifiche: Confirm that the new Cleveland SK1427305 capacitor's specifications (capacitance, voltage, temperature) match the requirements of the circuit.
  4. Rispettare la polarità: Carefully identify the positive (+) and negative (-) terminals on both the capacitor and the circuit board/wiring. Connect the capacitor with the correct polarity. Incorrect polarity will cause damage.
  5. Montaggio sicuro: Mount the capacitor securely using appropriate hardware. Ensure it is stable and not subject to excessive vibration.
  6. Connessioni terminali: Connect the circuit wires to the capacitor's screw terminals. Ensure connections are tight and secure to prevent arcing or poor contact.
  7. Ispezione finale: Before restoring power, visually inspect all connections for correctness and security.

5. Principi operativi

The Cleveland SK1427305 capacitor is a passive electronic component. Once installed in a circuit, it operates by storing electrical energy in an electric field. Its primary functions include:

The capacitor will function automatically within the designed parameters of the circuit it is integrated into, provided it is correctly installed and the circuit operates within its specified voltage e limiti di corrente.

6. Manutenzione

Capacitors are generally low-maintenance components. However, periodic inspection can help ensure longevity and prevent unexpected failures:

If any signs of damage or degradation are observed, the capacitor should be replaced immediately by qualified personnel after safely discharging it and disconnecting power.

7. Risoluzione Dei Problemi

Capacitor failures can manifest in various ways, often impacting the overall circuit performance. Common symptoms and potential causes include:

If any of these symptoms are observed, the capacitor is likely faulty and requires replacement. Always ensure power is disconnected and the capacitor is safely discharged before attempting any troubleshooting or replacement.

8. Specifiche

The following table details the key specifications for the Cleveland SK1427305 Capacitor:

SpecificazioneValore
MarcaCLEVELAND
Numero modello articoloCLESK1427305
Capacità4700 µF (Microfarads)
Volume di eserciziotage63 Volt CC
Volume massimotage63 Volt
Valutazione della temperatura105°C (as indicated on component)
MaterialeLead (terminals)
FormaRound (Cylindrical)
Dimensioni del prodotto2.25 x 1.4 x 1.4 pollici
Peso dell'articolo3.2 once
ProduttoreGAMMA CLEVELAND
ASINB00HVPDRDO

9. Garanzia e supporto

For warranty information regarding the Cleveland SK1427305 Capacitor, please refer to the terms and conditions provided by your point of purchase or contact the manufacturer directly. As an OEM replacement part, specific warranty details may vary.

For technical support or further inquiries, please reach out to the authorized distributor or the manufacturer, CLEVELAND RANGE, through their official support channels.

Documenti correlati - CLESK1427305

Preview Manuale dei componenti Cleveland SteamChef 22CET6.1
Manuale completo dei componenti per i modelli Cleveland Energy Star SteamChef 22CET6.1, che descrive in dettaglio componenti, gruppi e schemi elettrici per l'assistenza e la manutenzione.
Preview Manuale d'uso del generatore di vapore a doppio gas e del generatore di vapore a convezione Cleveland Gemini
Questo manuale dell'operatore (codice articolo GEMINI-OPM B 7/02) fornisce istruzioni dettagliate per l'uso, la cura, la manutenzione e la risoluzione dei problemi dei modelli 24CGA6.2 e 24CGA10.2 del generatore di vapore a doppio gas e del vaporizzatore a convezione Cleveland Gemini.
Preview Cleveland SteamChef 22CCGT6 Vaporiera a convezione senza collegamento a gas: Manuale di funzionamento, installazione e manutenzione
Manuale completo di funzionamento, installazione e manutenzione per il fornello a vapore a convezione senza allacciamento a gas Cleveland SteamChef 22CCGT6 con Easy Timer. Include linee guida di sicurezza, informazioni sul prodotto, procedure di installazione, istruzioni per l'uso, pulizia, manutenzione e risoluzione dei problemi.
Preview Cleveland SteamCraft Electric Convection Steamers with Easy Timer: Operation, Installation & Maintenance Manual
This comprehensive manual provides detailed instructions for the operation, installation, and maintenance of Cleveland SteamCraft Electric Convection Steamers with Easy Timer, models 21CET8 and 21CET16. It includes essential safety guidelines, troubleshooting tips, and preventative maintenance schedules for commercial kitchen environments.
Preview Cleveland SteamCraft 24CEA10.2 Vaporiera elettrica a convezione: Manuale di funzionamento, installazione e manutenzione
Guida completa per il vaporizzatore elettrico a convezione Cleveland SteamCraft 24CEA10.2, che illustra funzionamento, installazione, manutenzione, risoluzione dei problemi e procedure di sicurezza. Include istruzioni dettagliate per l'installazione, l'uso quotidiano, la pulizia e la manutenzione preventiva.
Preview Manuale d'uso e manutenzione di Cleveland SteamCraft Ultra 5 e Ultra 10
Manuale d'uso ufficiale per i forni a vapore a gas Cleveland SteamCraft Ultra 5 e Ultra 10. Fornisce informazioni essenziali su funzionamento sicuro, manutenzione, risoluzione dei problemi e cottura a vapore per cucine commerciali.