The Cen-Tech Digital Clamp-On Multimeter is a versatile electrical testing instrument designed for measuring AC/DC voltage, AC current, and resistance. It also features an insulation test function. Its clamp-on design allows for non-contact measurement of AC current, enhancing safety and convenience.

Figura 1: Fronte view of the Cen-Tech Digital Clamp-On Multimeter in its retail packaging. The packaging highlights key features such as clamp-style measurement, data hold, 500 volt resistance, and diode test capabilities.

Figura 2: Posteriore view of the Cen-Tech Digital Clamp-On Multimeter packaging. This view provides additional specifications and features, including low power indicator, included 9V battery, and dimensions.
Precauzioni di sicurezza
Always observe the following safety precautions when using the multimeter to prevent electric shock or personal injury, and to avoid damage to the meter or the equipment under test.
- Non applicare più del volume nominaletage, come indicato sul misuratore, tra i terminali o tra un terminale qualsiasi e la terra.
- Usare estrema cautela quando si lavora con voltages al di sopra di 60 V CC o 30 V CA RMS. Tale voltagrappresentano un rischio di scossa elettrica.
- Before making resistance measurements, disconnect power to the circuit and discharge all high-voltage condensatori.
- Non utilizzare il misuratore se appare danneggiato o se l'isolamento dei puntali di prova è compromesso.
- Ensure the function switch is in the correct position for the measurement being taken.
- Durante l'uso, tenere le dita dietro le apposite protezioni sui cavi di prova.
- Per garantire letture accurate, sostituire immediatamente la batteria quando appare l'indicatore di batteria scarica.
Impostare
Disimballaggio e ispezione
Carefully remove the multimeter and its accessories from the packaging. Inspect all components for any signs of damage. If any damage is found, contact customer support immediately.
Installazione della batteria
The multimeter requires a 9V battery (included). To install or replace the battery:
- Assicurarsi che il multimetro sia spento.
- Individuare il coperchio del vano batterie sul retro dell'unità.
- Utilizzare un cacciavite per rimuovere la vite che fissa il coperchio.
- Gently lift the cover and connect the 9V battery to the battery clip, observing correct polarity.
- Inserire la batteria nel vano e riposizionare il coperchio, fissandolo con la vite.
Collegamento dei cavi di prova
Insert the black test lead into the "COM" (common) jack and the red test lead into the "VΩmA" jack for voltage, resistance, and small current measurements. For AC current measurements using the clamp, test leads are not required unless simultaneous voltage readings are needed.
Istruzioni per l'uso
This section details how to perform various measurements with your Cen-Tech Digital Clamp-Sul multimetro.
Misurazione AC/DC Voltage
- Set the function switch to the desired ACV (Alternating Current Voltage) o DCV (Volume di corrente continua)tage) range. If the voltage è sconosciuto, iniziare con l'intervallo più alto e diminuire se necessario.
- Collegare il puntale di prova nero alla presa "COM" e il puntale di prova rosso alla presa "VΩmA".
- Collegare i puntali di prova in parallelo al circuito o al componente che si desidera misurare.
- Leggi il vol.tage valore sul display LCD.
Measuring AC Current (Clamp Funzione)
- Set the function switch to the ACA (Alternating Current Ampgamma eres).
- Aprire il clamp mascelle premendo il grilletto.
- Racchiudere solo un conduttore del circuito all'interno del clamp ganasce. Assicurarsi che le ganasce siano completamente chiuse.
- Leggere il valore corrente sul display LCD.
- Nota: il clamp measures current flowing through a single conductor. Do not clamp around multiple conductors (e.g., a power cord with both live and neutral wires) as the magnetic fields will cancel out, resulting in an inaccurate or zero reading.
Misurazione della resistenza
- Ensure the circuit or component is de-energized before measuring resistance. Disconnect power and discharge any capacitors.
- Set the function switch to the Ω (Ohms) range.
- Collegare il puntale di prova nero alla presa "COM" e il puntale di prova rosso alla presa "VΩmA".
- Collegare i puntali di prova al componente di cui si desidera misurare la resistenza.
- Leggere il valore della resistenza sul display LCD.
Test diodi
- Set the function switch to the diode symbol (usually shared with continuity or resistance).
- Collegare il puntale di prova nero alla presa "COM" e il puntale di prova rosso alla presa "VΩmA".
- Collegare il puntale rosso all'anodo e il puntale nero al catodo del diodo. Una tensione direttatagDovrebbe essere visualizzata la caduta di tensione (ad esempio da 0.5 V a 0.8 V per i diodi al silicio).
- Invertire i puntali. Il display dovrebbe visualizzare "OL" (Open Loop) per indicare un diodo funzionante.
Manutenzione
Pulizia
Pulisci la custodia con l'adamp panno e detergente delicato. Non utilizzare abrasivi o solventi. Assicurarsi che il misuratore sia completamente asciutto prima dell'uso.
Sostituzione della batteria
Refer to the "Battery Installation" section under Setup for instructions on replacing the 9V battery when the low battery indicator appears on the display.
Sostituzione del fusibile
This model typically does not have user-replaceable fuses for current ranges measured by the clamp. For internal fuse replacement (if applicable for other functions), it is recommended to contact qualified service personnel.
Magazzinaggio
Quando non si utilizza il multimetro per lunghi periodi, rimuovere la batteria per evitare perdite e conservarlo in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun display o display poco luminoso | Batteria scarica o scarica | Sostituire la batteria da 9V. |
| "OL" (sovraccarico) visualizzato | La misurazione supera l'intervallo selezionato; circuito aperto (per resistenza/continuità) | Select a higher range; Check for open circuit in the component or test leads. |
| Letture imprecise | Low battery; Incorrect range selected; External interference | Replace battery; Select appropriate range; Move away from strong electromagnetic fields. |
| No AC current reading with clamp | Clamping around multiple conductors (e.g., a power cord) | Ensure only a single conductor is within the clamp mascelle. |
Specifiche
- Modello: 66897/95652
- Volume AC/DCtage Gamma: As per product specifications (typically up to 600V)
- Intervallo di corrente CA: As per product specifications (typically up to 600A)
- Intervallo di resistenza: As per product specifications (typically up to 20MΩ)
- Prova del diodo: SÌ
- Energia: Batteria 9V (inclusa)
- Display: LCD
- Dimensioni: 9" x 3-1/4" x 1-1/2"
- Peso: 454 grammi
Nota: Specific ranges may vary slightly. Refer to the product packaging or official documentation for precise specifications.
Garanzia e supporto
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your product packaging or visit the official Cen-Tech websito. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.
Produttore: Cen-Tech
ASIN: B00JKSOG8U
Codice UPC: 792363668972