1. Introduzione
The Elitech RC-5 is a multi-use USB temperature data logger designed for precise temperature monitoring. It features a wide measuring range, high accuracy, and a large storage capacity of 32,000 recording points. With its built-in USB connector, data can be easily downloaded and reports generated without the need for additional cables or readers. The device is suitable for various applications requiring cold chain management, including the storage and transportation of sensitive products.

2. Cosa c'è nella scatola
- 1 x Elitech RC-5 Data Logger
- 1 batterie CR2032
- 1 x Manuale utente
3. Impostazione
3.1. Installazione della batteria
- Locate the battery compartment cover on the back of the data logger.
- Use a coin or similar tool to gently twist and open the battery cover.
- Insert the CR2032 battery with the positive (+) pole facing upwards, ensuring it slides under the small metal clip.
- Richiudere il coperchio della batteria e ruotarlo per fissarlo.

3.2. Software Installation and Parameter Configuration
Before using the data logger, install the Elitechlog software on your computer. The software allows you to configure logging parameters and retrieve data.
- Download the Elitechlog software from the official Elitech websito.
- Install the software following the on-screen prompts.
- Connect the RC-5 data logger to your computer's USB port.
- Open the Elitechlog software and navigate to the 'Parameter' or 'Settings' tab.
- Configure desired settings such as log interval (e.g., 10 seconds to 24 hours), temperature unit (Celsius/Fahrenheit), alarm limits, and start mode.
- Click 'Save Parameter' to apply the settings to the data logger.
- Safely eject and disconnect the data logger from the computer.

3.3. Video Guide: Setup and Parameter Configuration
Video 1: This video demonstrates the battery installation process, connecting the RC-5 data logger to a computer, and configuring logging parameters using the Elitechlog software.
4. Istruzioni per l'uso
4.1. Avvio della registrazione dei dati
After configuring parameters, you can start the data logger:
- Press and hold the left 'Play' button (triangle icon) on the data logger for more than 4 seconds.
- A triangle sign will firmly light up on the LCD screen, indicating that logging has started.
4.2. Cycling Through Display Modes
While logging, short press the 'Play' button to cycle through various display modes on the LCD screen:
- Temperatura attuale
- Logging Points (number of recorded data points)
- Ora corrente
- Data corrente
- Maximum Temperature recorded
- Minimum Temperature recorded

4.3. Interruzione della registrazione dei dati
To stop data logging:
- Press and hold the right 'Pause' button (two vertical lines icon) on the data logger for more than 4 seconds.
- The logging indicator on the screen will disappear, confirming that logging has stopped.
5. Recupero dei dati
The Elitech RC-5 allows for easy data retrieval and report generation in multiple formats.
- Connect the RC-5 data logger to your computer's USB port.
- The device will automatically generate a PDF report, which can be accessed directly from the device's storage.
- For more detailed analysis, open the Elitechlog software.
- In the software, click on 'Export Data' and choose your preferred format (Excel, PDF, TXT, etc.) to save the data to your computer.

5.1. Video Guide: Data Export
Video 2: Questo video fornisce una rapida panoramicaview of the Elitech RC-5, including connecting it to a computer and exporting data.
6. Manutenzione
6.1. Sostituzione della batteria
The RC-5 uses a replaceable CR2032 battery, offering up to 6 months of battery life depending on usage and logging interval. Replace the battery when the low battery indicator appears on the LCD screen. Refer to section 3.1 for battery installation instructions.
6.2. Pulizia e cura
To ensure optimal performance and longevity of your data logger:
- Wipe clean the device with a soft, damp panno. Non usare detergenti abrasivi.
- The device is freezer safe and has an IP65 protection grade, meaning it is protected against dust and low-pressure water jets. However, avoid prolonged submersion in water.
7. Risoluzione Dei Problemi
7.1. Software Not Recognizing Device
- Ensure the Elitechlog software is correctly installed. If issues persist, try reinstalling the software.
- Verify the data logger is securely plugged into a functional USB port.
- Try a different USB port or computer to rule out port-specific issues.
7.2. Logging Not Starting
- Assicurarsi che la batteria sia installata correttamente e che abbia una carica sufficiente.
- Confirm that the 'Start Mode' in the software parameters is set correctly (e.g., 'Start by button-press' or 'Timer start').
- Press and hold the 'Play' button for the required duration (more than 4 seconds) until the triangle indicator appears.
7.3. Letture della temperatura imprecise
- Allow the device to stabilize in the environment for at least 30 minutes after handling or connecting to a computer, as these actions can temporarily affect its internal temperature.
- Ensure the device is not exposed to direct heat sources or extreme cold during measurement, unless that is the intended monitoring environment.
8. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Modello | RC-5 |
| Campo di misurazione della temperatura | Da -30 ℃ a 70 ℃ (da -22 ℉ a 158 ℉) |
| Precisione della temperatura | ±0.5℃ (±0.9℉) for -20℃ to 40℃; ±1℃ (±1.8℉) for others |
| Risoluzione | 0.1 ℃ / 0.1 ℉ |
| Capacità di archiviazione dei dati | 32,000 punti |
| Intervallo di registro | Configurable from 10 seconds to 24 hours |
| Batteria | CR2032 Litio Metallo (incluso) |
| Durata della batteria | Fino a 6 mesi (tipico) |
| Grado di protezione | Grado di protezione IP65 |
| Connettività | USB |
| Tipo di visualizzazione | LCD |
| Dimensioni del prodotto | 4 x 1 x 5.2 pollici; 1.41 once |
| Certificazioni | CE, FCC, RoHS, RAEE |
9. Garanzia e supporto
For any technical assistance or inquiries, Elitech offers 24/7 US Technician Support via Email and Phone. Please refer to the contact information provided in your product packaging or on the official Elitech websito per i dettagli.
Calibration certificates are available upon request. Please email or message Elitech for assistance.