1. Introduzione
Thank you for choosing the Microlife BP A80 Semi-automatic Upper Arm Blood Pressure Monitor. This device is designed for accurate and reliable measurement of blood pressure in adults. Please read this instruction manual thoroughly before using the device to ensure safe and correct operation. Keep this manual for future reference.
2. Informazioni importanti sulla sicurezza
- Consult your doctor before using this device if you have any medical conditions.
- Do not self-diagnose or self-medicate based on blood pressure measurements. Always consult a healthcare professional.
- This device is not suitable for use on infants, children, or pregnant women without medical advice.
- Non utilizzare il dispositivo in un veicolo in movimento o su un aereo.
- Tenere il dispositivo e i suoi componenti fuori dalla portata dei bambini.
- Use only Microlife-approved cuffs and accessories.
- Avoid strong electromagnetic fields, such as those near mobile phones or microwave ovens, during use.
3. Prodotto finitoview
Familiarize yourself with the components of your Microlife BP A80 blood pressure monitor:
Figura 1: Microlife BP A80 Blood Pressure Monitor showing the main unit, display, power button, cuff, and inflation bulb.
- Unità principale: Contains the electronics and display.
- Display: Shows blood pressure readings (systolic, diastolic, pulse) and other indicators.
- Pulsante di accensione: Utilizzato per accendere e spegnere il dispositivo.
- Polsino: Applied to the upper arm for measurement.
- Inflation Bulb: Used to manually inflate the cuff.
- Connettore del polsino: Port on the main unit for connecting the cuff tube.
Figura 2: Dettagliato view of the Microlife BP A80 display, highlighting the blood pressure values (systolic, diastolic, pulse) and the integrated WHO blood pressure classification indicator.
4. Impostazione
4.1. Installazione della batteria
- Open the battery compartment cover located on the bottom or back of the device.
- Insert four 1.5V AA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Chiudere saldamente il coperchio del vano batterie.
- Se sul display appare il simbolo della batteria, sostituire tutte le batterie.
4.2. Collegamento del bracciale
- Insert the air tube connector of the cuff firmly into the cuff socket on the left side of the monitor.
- Assicurarsi che il collegamento sia saldo per evitare perdite d'aria durante la misurazione.
5. Istruzioni per l'uso
5.1. Prima della misurazione
- Evitare di mangiare, fumare o fare esercizio fisico per almeno 30 minuti prima della misurazione.
- Riposare per 5-10 minuti in un ambiente tranquillo prima di effettuare la misurazione.
- Siediti comodamente con la schiena appoggiata e i piedi ben appoggiati sul pavimento. Non accavallare le gambe.
- Posizionare il braccio su una superficie piana in modo che il bracciale sia all'altezza del cuore.
- Togli gli indumenti attillati dalla parte superiore del braccio.
5.2. Applicazione del bracciale
- Posizionare il bracciale sulla parte superiore del braccio nudo, circa 2-3 cm sopra l'articolazione del gomito.
- Ensure the artery mark on the cuff aligns with your brachial artery (on the inside of your arm).
- Avvolgi il bracciale attorno al braccio, ma non troppo stretto. Dovresti riuscire a infilare due dita tra il bracciale e il braccio.
5.3. Effettuare una misurazione
- Premere il tasto ACCESO/SPENTO button to turn on the monitor. The display will show all segments briefly.
- Once the display shows "0", begin inflating the cuff by repeatedly squeezing the inflation bulb.
- Inflate the cuff until the pressure displayed is about 30 mmHg higher than your usual systolic pressure. If you don't know your usual pressure, inflate to 180-200 mmHg.
- Stop inflating. The device will automatically deflate the cuff slowly and measure your blood pressure.
- Once the measurement is complete, your systolic pressure, diastolic pressure, and pulse rate will be displayed.
- Premere il tasto ACCESO/SPENTO button to turn off the device. If you forget, it will automatically shut off after approximately 1 minute.
6. Comprendere le tue letture
Your blood pressure monitor displays three values:
- Pressione sistolica (SYS): The top number, indicating the pressure when your heart beats.
- Pressione diastolica (DIA): The bottom number, indicating the pressure when your heart rests between beats.
- Pulsazioni: La tua frequenza cardiaca al minuto.
The Microlife BP A80 also features a WHO (World Health Organization) blood pressure classification indicator on the display, which uses a color scale to help you interpret your readings:
| Categoria | Sistolica (mmHg) | Diastolica (mmHg) | Colore indicatore |
|---|---|---|---|
| Ottimale | < 120 | < 80 | Verde |
| Normale | 120-129 | 80-84 | Verde chiaro |
| Normale alto | 130-139 | 85-89 | Giallo |
| Ipertensione di grado 1 | 140-159 | 90-99 | Arancia |
| Ipertensione di grado 2 | 160-179 | 100-109 | Rosso |
| Ipertensione di grado 3 | ≥ 180 | ≥ 110 | Rosso scuro |
Note: This classification is a general guideline. Always consult your doctor for interpretation of your blood pressure readings.
7. Manutenzione
7.1. Pulizia
- Clean the monitor and cuff gently with a soft, dry cloth.
- Se necessario, utilizzare un panno leggermente dampened with water or a mild detergent. Do not use abrasive cleaners or solvents.
- Non immergere il dispositivo o il bracciale in acqua.
7.2. Conservazione
- Store the device and cuff in a clean, dry place, away from direct sunlight and extreme temperatures.
- Se il dispositivo non verrà utilizzato per un periodo prolungato, rimuovere le batterie per evitare perdite.
- Evitare di far cadere o sottoporre il dispositivo a forti impatti.
8. Risoluzione Dei Problemi
If you encounter any issues with your Microlife BP A80, please refer to the following table:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il dispositivo non si accende. | Le batterie sono scariche o inserite in modo errato. | Sostituire le batterie con batterie nuove, assicurandosi che la polarità sia corretta. |
| "E1" or "Error" displayed. | Manicotto non collegato correttamente o perdita d'aria. | Check cuff connection. Re-apply cuff snugly. |
| "E2" displayed. | Movement during measurement or irregular pulse. | Remain still and quiet during measurement. Repeat measurement after a few minutes. |
| Letture incoerenti. | Improper cuff placement, incorrect body position, or external factors. | Ensure correct cuff placement and body posture. Avoid talking or moving. Take multiple readings at different times. |
If the problem persists, contact Microlife customer support.
9. Specifiche
- Modello: PA A80
- Metodo di misurazione: oscillometrico
- Campo di misura:
- Blood Pressure: 20-280 mmHg
- Pulse: 40-200 beats per minute
- Precisione:
- Pressione sanguigna: ±3 mmHg
- Impulso: ±5% della lettura
- Fonte di energia: 4 batterie AA da 1.5 V
- Tipo di visualizzazione: LCD
- Dimensioni: Approximately 16.5 x 16 x 10 cm (as per package dimensions, actual device may vary slightly)
- Peso: Approximately 600 grams (including batteries, as per package weight)
- Condizioni operative: 10-40 °C (50-104 °F), 15-95% relative humidity non-condensing
- Condizioni di conservazione: -20-55 °C (-4-131 °F), 15-95% relative humidity non-condensing
- Codice articolo internazionale (EAN): 04719003310080
10. Garanzia e supporto
Microlife products are manufactured to the highest quality standards. For detailed warranty information specific to your region, please refer to the warranty card included with your product or visit the official Microlife websito.
For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Microlife customer service. Contact details can typically be found on the Microlife websito o sulla confezione del prodotto.
Websito: www.microlife.com