Oakton AO-35613-05

Oakton ATC Probe AO-35613-05 Instruction Manual

Automatic Temperature Compensation Probe for pH and Ion Meters

1. Introduzione

This manual provides essential instructions for the proper setup, operation, and maintenance of the Oakton ATC Probe, Model AO-35613-05. This probe is designed to provide automatic temperature compensation (ATC) for compatible Oakton pH and Ion meters, ensuring accurate and reliable measurements across varying sample temperature.

2. Prodotto finitoview

Oakton ATC Probe AO-35613-05

Image 1: Oakton ATC Probe AO-35613-05. This image displays the black cylindrical handle of the probe connected to a thin, flexible black cable, which leads to a metal probe tip.

The Oakton ATC Probe features a corrosion-resistant stainless steel 30 K thermistor, which is crucial for accurate temperature detection. The thermistor is encased within a durable polymer handle, designed for longevity and ease of handling. The probe is equipped with a 3.3 ft (1-meter) cable for convenient connection to your meter.

Caratteristiche principali:

3. Compatibilità

This ATC probe is designed for use with a variety of Oakton pH and Ion meters. Ensure your meter is listed below for proper functionality:

4. Impostazione

  1. Disimballaggio: Carefully remove the ATC probe from its packaging. Inspect the probe and cable for any visible damage.
  2. Connessione: Locate the dedicated ATC input port on your compatible Oakton pH or Ion meter. Gently insert the probe's connector into this port. Ensure the connection is firm and secure to prevent intermittent readings.
  3. Posizionamento: For accurate temperature compensation, the metal tip of the ATC probe must be immersed in the sample solution alongside the pH or ion electrode. Both probes should be in close proximity within the sample to ensure they are measuring the same temperature.

5. Funzionamento

  1. Accensione: Turn on your Oakton pH or Ion meter after connecting the ATC probe.
  2. Immersione: Place both the ATC probe and the primary measuring electrode (pH or ion) into the sample solution. Ensure that the sensing elements of both probes are fully immersed and stable within the solution.
  3. Misurazione: The meter will automatically detect the temperature from the ATC probe and apply the necessary compensation to the pH or ion reading. Proceed with your standard measurement procedure as outlined in your specific meter's instruction manual. The probe is designed to operate within a temperature range of 0 to 100°C.

6. Manutenzione

Proper maintenance ensures the longevity and accuracy of your ATC probe.

7. Risoluzione Dei Problemi

If you encounter issues with your ATC probe, consider the following:

8. Specifiche

ParametroSpecificazione
Tipo di prodottoForniture di laboratorio
Numero di modelloAO-35613-05
Tipo di termistore30 mila
Materiale della sondaCorrosion-resistant stainless steel
Materiale della manigliaDurable polymer
Probe Dimensions (L x Dia)Dimensioni: 88 mm x 3 mm
Lunghezza della maniglia67 millimetri
Lunghezza del cavo3.3 piedi (1 m)
Intervallo di temperaturada 0 a 100°C
Dimensioni del pacco10.51 x 4.09 x 2.2 pollici (26.7 x 10.4 x 5.6 cm)
Peso5.5 once (156 g)
Paese di origineMalaysia
ProduttoreCOLE-PARMER

9. Garanzia e supporto

For detailed warranty information, technical assistance, or to inquire about replacement parts, please refer to the documentation provided with your primary Oakton pH or Ion meter. Alternatively, you may contact Oakton customer service directly through their official websito o canali di contatto.

Documenti correlati - AO-35613-05

Preview Misuratori OAKTON ION Acorn Series: Istruzioni per l'uso e guida
Manuale operativo completo per i misuratori di pH/ioni OAKTON ION 5 e ION 6 della serie Acorn. Descrive la configurazione, la calibrazione, la misurazione, la manutenzione e la risoluzione dei problemi per un'analisi accurata della qualità dell'acqua.
Preview Catalogo di misuratori e tester per la qualità dell'acqua Oakton | Cole-Parmer
Esplora la gamma completa di misuratori e tester della qualità dell'acqua Oakton di Cole-Parmer, dotati di soluzioni avanzate per la misurazione di pH, conduttività e ORP per analisi accurate.
Preview Istruzioni per l'uso del misuratore di pH/ORP/TEMP OAKTON pH 700
Questo documento fornisce istruzioni operative complete per il misuratore di pH/ORP/TEMP OAKTON pH 700, che ne descrivono le caratteristiche, la calibrazione, le procedure di misurazione, la risoluzione dei problemi e le specifiche tecniche.
Preview Manuale di istruzioni per il misuratore portatile della qualità dell'acqua Oakton serie 300
Manuale di istruzioni per i misuratori portatili della qualità dell'acqua Oakton serie 300 (modelli 350, 360, 380). Descrive funzionamento, calibrazione, manutenzione, sicurezza e specifiche per un'analisi accurata dell'acqua.
Preview Manuale di istruzioni del misuratore di ossigeno disciolto Oakton DO250/DO260
Manuale di istruzioni completo per i misuratori di ossigeno disciolto Oakton DO250 e DO260, che copre il prodotto oltreview, operazioni di base, calibrazione, gestione dei dati, configurazione, manutenzione, risoluzione dei problemi e precauzioni di sicurezza.
Preview Timer OAKTON 410 con allarme: istruzioni per l'uso e specifiche
Istruzioni operative complete e specifiche per il timer con sveglia OAKTON 410 (modello WD-35002-00), che ne descrivono in dettaglio le caratteristiche, le funzioni dei pulsanti, le modalità di temporizzazione e le impostazioni della sveglia.