Introduzione
The AC Infinity Controller 2 is an intelligent thermal fan controller designed to manage the temperature and airflow within AV cabinets, server racks, and other enclosures. It features an on-board processor and a digital LCD display, providing precise control over connected fans. This manual provides essential information for the setup, operation, and maintenance of your Controller 2.
Caratteristiche principali
- Intelligent thermal fan controller with on-board processor and digital LCD display.
- Controls up to six AC Infinity Cabinet and USB Fans.
- Automated programming that self-adjusts cooling power in response to changing temperatures.
- Features an alarm system, display lock, six fan speeds, two buffer options, and power failure memory.
- Complete kit includes precision thermal probe, mounting screws, and power wall adapter.

Image: The AC Infinity Controller 2 display, highlighting its intelligent programming, six fan speeds, corded thermal probe, and alarm/control lock features.
Guida all'installazione
- Disimballare i componenti: Carefully remove the Controller 2, thermal probe, power adapter, and any included mounting hardware from the packaging.
- Montaggio (facoltativo): If desired, use the provided mounting screws to secure the Controller 2 to a flat surface. Ensure adequate ventilation around the unit.
- Connect Thermal Probe: Plug the precision thermal probe into the designated "SENSOR" port on the Controller 2. Position the probe in the area where temperature monitoring is critical, typically near heat-generating components.
- Connetti i fan: Plug your AC Infinity Cabinet or USB Fans into the "FAN" ports on the Controller 2. The controller supports up to six fans.
- Accensione: Connect the power wall adapter to the "POWER" port on the Controller 2, then plug the adapter into a standard electrical outlet. The LCD display should illuminate.

Image: The rear connections of the AC Infinity Controller 2, showing ports for the thermal probe, fans, and power input, illustrating its plug-and-play design.
Istruzioni per l'uso
Mostra sopraview
The LCD display shows the current probe temperature, the set temperature, and fan speed settings. Use the navigation buttons to adjust settings.

Immagine: Frontale view of the AC Infinity Controller 2, showcasing its digital LCD display and control buttons, along with the detached thermal probe.
Setting Temperature and Fan Speed
- Premere il tasto "SETTING" pulsante per accedere alla modalità di regolazione della temperatura.
- Utilizzare il UP E GIÙ arrows to set your desired temperature threshold. Fans will activate or adjust speed based on this setting.
- Premere il tasto "FAN SPEED" button (often integrated with setting button) to cycle through six fan speed settings, from silent to powerful.
- The controller features automated programming that self-adjusts cooling power in response to changing temperatures, ensuring optimal performance.
Alarm System and Display Lock
- The alarm system can be configured to alert you if the temperature exceeds a set limit. Refer to the full user manual for detailed alarm setup.
- A display lock feature prevents accidental changes to settings.
Manutenzione
- Pulizia: Wipe the controller and thermal probe with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
- Cura della sonda: Ensure the thermal probe remains clean and free of debris for accurate temperature readings. The probe is water resistant, but avoid prolonged submersion.
- Manutenzione del ventilatore: Periodically clean connected fans to ensure optimal airflow and prevent dust buildup.

Image: A close-up of the AC Infinity thermal probe, emphasizing its six-foot cord and thermalloy head design for precise, water-resistant temperature measurements.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il display è spento / Nessuna alimentazione | Adattatore di alimentazione non collegato o presa difettosa. | Ensure power adapter is securely plugged into the controller and a working electrical outlet. Check for power failure memory settings. |
| I ventilatori non si accendono | Temperature not met, fans not connected, or fan speed set to zero. | Verify the probe temperature is above the set threshold. Check fan connections. Increase fan speed setting. |
| Letture della temperatura imprecise | Thermal probe is dirty, damaged, or improperly placed. | Clean the thermal probe. Ensure it is placed in an area representative of the cabinet's temperature. Inspect for damage. |
| Alarm constantly triggers | Alarm threshold set too low or insufficient cooling. | Adjust the alarm threshold to a higher temperature. Ensure fans are operating effectively and consider adding more fans if needed. |
Specifiche
| Attributo | Valore |
|---|---|
| Modello | AI-ATC |
| Marca | AC Infinito |
| Peso dell'articolo | 6.4 once |
| Tipo di visualizzazione | LCD |
| Temperatura di esercizio | 32 gradi Fahrenheit (0°C) |
| Codice UPC | 854759004402 |
| Dimensioni del prodotto | 5.31 x 1.1 x 3.11 pollici (13.5 x 2.8 x 7.9 cm) |
| Fans Supported | Up to six AC Infinity Cabinet and USB Fans |
| Impostazioni della velocità della ventola | 6 |
| Intervallo di temperatura | da 32 a 140 °F (da 0 a 60 °C) |
| Voltage | 5 Volt |
| Colore | Nero |
| Materiale | Plastica |

Image: Detailed diagram showing the dimensions and key specifications of the AC Infinity Controller 2 and its power components.
Garanzia e supporto
For warranty information and technical support, please refer to the official AC Infinity websito o contattare direttamente il servizio clienti. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.
Additional support documents, including a PDF user manual, may be available on the product's Amazon listing page or the manufacturer's websito.
Per ulteriore assistenza, puoi visitare il Negozio AC Infinity su Amazon.