Greenlee CM-660

Greenlee CM-660 General Purpose AC Clamp Manuale di istruzioni del misuratore

Modello: CM-660

1. Introduzione

The Greenlee CM-660 is a general-purpose AC True RMS clamp meter designed for accurate electrical measurements. This instrument is capable of measuring AC currents, DC voltages, resistance, and frequency. It incorporates a digital low-pass filter for precise readings on variable frequency drives (VFDs) and features AmpTip™ technology for enhanced accuracy on small wires carrying low currents (60 amps o meno).

Key features include non-contact AC voltage detection, continuity testing, and diode testing. The meter can record average, maximum, and minimum readings, and offers two voltage detection modes: non-contact or single test lead. It is powered by two 1.5V AAA batteries and comes with test leads and a carrying case for convenience. The CM-660 has a 6000-count LCD display and a 1.18-inch jaw opening. It is UL listed, ensuring compliance with safety standards.

Greenlee CM-660 Clamp metro

Figure 1.1: Greenlee CM-660 General Purpose AC Clamp metro.

2. Informazioni sulla sicurezza

Always adhere to safety precautions when using electrical test equipment. Failure to do so may result in injury or damage to the meter.

3. Impostazione

3.1 Installazione della batteria

The Greenlee CM-660 requires two 1.5V AAA batteries for operation. These are typically included with the meter.

  1. Ensure the meter is turned OFF and disconnected from any electrical circuits.
  2. Individuare il coperchio del vano batterie sul retro del misuratore.
  3. Utilizzare un cacciavite per allentare la vite che fissa il coperchio della batteria.
  4. Remove the cover and insert two AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Riposizionare il coperchio della batteria e serrare saldamente la vite.

3.2 Ispezione iniziale

Before first use, and periodically thereafter, perform a visual inspection of the meter and its accessories.

Greenlee CM-660 Test Leads and Carrying Case

Figure 3.1: Included test leads and carrying case.

4. Istruzioni per l'uso

The Greenlee CM-660 offers various measurement functions. Always select the appropriate function before making a measurement.

4.1 metri sopraview

Greenlee CM-660 Clamp Meter Features Diagram

Figure 4.1: Diagram illustrating key features of the Greenlee CM-660 clamp meter, including the clamp jaw, AmpTip, non-contact AC voltage rilevamento, vol ACtage with digital filter, over-molded grip, and display.

4.2 Misurazione della corrente alternata (Clamp)

  1. Turn the function dial to the AC current (A~) position.
  2. Aprire il clamp mascella premendo la leva.
  3. Racchiudere un singolo conduttore con il clamp jaw. Ensure the jaw is fully closed around the conductor.
  4. Leggere il valore della corrente alternata sul display.
  5. For small wires carrying 60 amps or less, the AmpTip™ feature automatically provides increased accuracy.
Greenlee CM-660 Clamp Meter measuring current on a wire

Figure 4.2: The CM-660 clamp contatore in uso, misurazione della corrente tramite clampattorno ad un unico conduttore.

4.3 Misurazione del volume CCtage

  1. Insert the red test lead into the VΩHz input and the black test lead into the COM input.
  2. Ruotare la manopola delle funzioni su DC voltage (V=) posizione.
  3. Collegare il puntale di prova rosso al lato positivo del circuito e il puntale di prova nero al lato negativo.
  4. Leggi il DC voltage valore sul display.

4.4 Misurazione della resistenza

  1. Prima di misurare la resistenza, assicurarsi che il circuito sia disattivato.
  2. Insert the red test lead into the VΩHz input and the black test lead into the COM input.
  3. Ruotare la manopola delle funzioni sulla posizione Resistenza (Ω).
  4. Collegare i puntali di prova al componente o al circuito da misurare.
  5. Leggere il valore di resistenza sul display.

4.5 Prova di continuità

  1. Prima di eseguire un test di continuità, assicurarsi che il circuito sia disattivato.
  2. Insert the red test lead into the VΩHz input and the black test lead into the COM input.
  3. Turn the function dial to the Continuity (Buzzer symbol) position.
  4. Collegare i puntali di prova al circuito o al componente.
  5. The meter will emit an audible tone if continuity is detected (low resistance).

4.6 Test diodi

  1. Prima di eseguire un test dei diodi, assicurarsi che il circuito sia disattivato.
  2. Insert the red test lead into the VΩHz input and the black test lead into the COM input.
  3. Turn the function dial to the Diode (Diode symbol) position.
  4. Collegare il puntale di prova rosso all'anodo e il puntale di prova nero al catodo del diodo.
  5. Il display mostrerà il volume in avantitage caduta. Invertire i cavi; il display dovrebbe visualizzare "OL" (linea aperta) per un diodo funzionante.

4.7 Vol. AC senza contattotage rilevamento

  1. Turn the function dial to the NCV (Non-Contact Voltage) posizione.
  2. Hold the meter with the NCV sensor near the conductor or outlet.
  3. Se AC voltage is present, the meter will indicate with an audible beep and/or visual indicator.
  4. AVVERTIMENTO: This feature is for preliminary detection only. Always verify voltage presence and magnitude with direct contact measurements using test leads.

5. Manutenzione

Proper maintenance ensures the longevity and accuracy of your Greenlee CM-660 clamp metro.

5.1 Pulizia

5.2 Sostituzione della batteria

Refer to Section 3.1 for battery installation instructions. Replace batteries promptly when the low battery indicator appears on the display to ensure accurate readings.

5.3 Conservazione

6. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il misuratore non si accende.Batterie scariche o installate in modo errato.Controllare la polarità delle batterie; sostituire le batterie.
Viene visualizzato "OL" (sovraccarico).La misurazione supera la portata del misuratore.Assicurarsi che la misurazione rientri nell'intervallo specificato dal misuratore.
Letture imprecise.
  • Dirty test leads/probes.
  • È stata selezionata una funzione errata.
  • Interferenza elettromagnetica esterna.
  • Batteria scarica.
  • Clean test leads and probes.
  • Select the correct measurement function.
  • Move away from strong magnetic fields.
  • Sostituire le batterie.
Nessun segnale acustico di continuità.
  • Circuit is open.
  • Test leads are faulty.
  • Verify the circuit path.
  • Test leads on a known good conductor.

7. Specifiche

The following table outlines the key specifications for the Greenlee CM-660 General Purpose AC Clamp metro.

CaratteristicaSpecificazione
ModelloCM-660
Tipo di misurazioneAC Current, DC Voltage, Resistance, Frequency, Continuity, Diode
Gamma di corrente CAFino a 600 Amps
Volume DCtage GammaFino a 600 V CC
Volume ACtage GammaFino a 600 VAC
Intervallo di resistenzaUp to 60 kΩ
Gamma di frequenza50/60 Hz (voltage/AmpTip currents), 50-400 Hz (higher currents)
Display6000 Count LCD
Apertura della mascella1.18 pollici (30 mm)
Fonte di alimentazione2 batterie AAA da 1.5 V
Valutazione di sicurezzaUL Listed, CAT IV 300V, CAT III 600V
Dimensioni (L x P x A)5.5 x 11.4 x 2.2 pollici (circa)
Peso dell'articolo16 once (1 libbra)
Caratteristiche specialiAmpTip™, Digital Low Pass Filter, Non-Contact AC Voltage Detection, Max/Min/Avg Recording, Data Hold, Auto Power Off
Greenlee CM-660 Clamp Meter size comparison in hand

Figure 7.1: Approximate dimensions of the CM-660 clamp meter shown in hand for scale.

8. Garanzia e supporto

8.1 Informazioni sulla garanzia

Greenlee products are manufactured to high standards and are backed by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions applicable to your CM-660 clamp meter, please refer to the warranty card included with your product or visit the official Greenlee websito. Conservare la prova d'acquisto per eventuali reclami in garanzia.

8.2 Assistenza clienti

For technical assistance, troubleshooting, or service inquiries, please contact Greenlee customer support. Contact information can typically be found on the Greenlee websito o nella confezione del prodotto.

Risorse online: For additional product information, FAQs, and support, visit the official Greenlee websito: www.greenlee.com

Product Videos and Demonstrations: For product videos and demonstrations, you may visit the link provided in some product documentation: http://tagr.com/t/V3v6VF

Documenti correlati - CM-660

Preview Greenlee CM-450 Digital Clamp-on Meter Instruction Manual
This instruction manual for the Greenlee CM-450 Digital Clamp-on Meter provides comprehensive guidance on safe operation, features, specifications, and troubleshooting for this versatile electrical testing device.
Preview Manuale di istruzioni del multimetro digitale Greenlee DM-40
Manuale d'uso del multimetro digitale Greenlee DM-40, che descrive in dettaglio le sue caratteristiche, il funzionamento, le istruzioni di sicurezza e le specifiche per i test elettrici.
Preview Manuale di istruzioni per la piegatrice a segmenti Greenlee 777
Manuale di istruzioni per la piegatrice per tubi Greenlee 777 Segment Bender, che fornisce indicazioni dettagliate sul funzionamento sicuro, la configurazione, le tecniche di piegatura, la manutenzione e l'identificazione dei componenti per questo strumento di piegatura dei tubi.
Preview Greenlee DM-20, DM-40, DM-60: Scheda tecnica dei multimetri digitali a portata manuale
Esplora le serie di multimetri digitali manuali Greenlee DM-20, DM-40 e DM-60. Le caratteristiche includono la tensione CA/CCtagMisurazione di corrente, resistenza, continuità, test diodi e temperatura (DM-40). Approvato UL e CE con garanzia limitata a vita.
Preview Manuale di istruzioni del termometro a infrarossi Greenlee TG-1000
Manuale di istruzioni completo per il termometro a infrarossi Greenlee TG-1000. Scopri le sue caratteristiche, il funzionamento sicuro, la manutenzione e la risoluzione dei problemi per misurazioni accurate della temperatura senza contatto in diverse applicazioni.
Preview Manuale di istruzioni del termometro a infrarossi e a contatto Greenlee TG-2000
Manuale di istruzioni per il termometro a infrarossi e a contatto Greenlee TG-2000, che descrive in dettaglio le sue caratteristiche, le precauzioni di sicurezza, il funzionamento, la risoluzione dei problemi, l'emissività, la precisione, le specifiche e la manutenzione.