1. Introduzione e oltreview
This manual provides essential information for the safe and efficient operation, setup, and maintenance of your AL-KO 3500-C Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The AL-KO 3500-C is a versatile and powerful gasoline generator designed to provide reliable electrical power in various settings, including construction sites, agricultural applications, outdoor events, camping, and as an emergency power source. Its robust design and efficient 4-stroke engine ensure consistent performance.

Image 1.1: The AL-KO 3500-C Generator, a red and black portable power unit with a protective frame.
2. Istruzioni di sicurezza
Operating a generator requires adherence to strict safety protocols to prevent accidents, injury, or property damage. Always prioritize safety.
2.1 Sicurezza generale
- Pericolo di monossido di carbonio: Never operate the generator indoors or in enclosed spaces. Generators produce carbon monoxide, an odorless, colorless, and deadly gas. Ensure adequate ventilation at all times.
- Rischio di incendio: La benzina è altamente infiammabile. Effettuare il rifornimento in un'area ben ventilata, a motore spento e freddo. Non fumare né avvicinare fiamme libere al generatore. Conservare il carburante in contenitori approvati, lontano da fonti di calore.
- Rischio di scossa elettrica: Do not operate the generator in wet conditions. Ensure all electrical connections are secure and dry. Use only grounded extension cords and appliances.
- Superfici calde: Il motore e la marmitta del generatore diventano molto caldi durante il funzionamento e rimangono caldi per un certo periodo di tempo dopo lo spegnimento. Evitare il contatto per prevenire ustioni.
- Bambini e animali domestici: Keep children and pets away from the generator during operation and while it is cooling down.
2.2 Caratteristiche di sicurezza specifiche del prodotto
- The generator is equipped with an automatic shutdown mechanism in case of low oil levels, protecting the engine from damage.
- It features protection against the ingress of water and foreign objects, enhancing operational safety.
3. Caratteristiche del prodotto
The AL-KO 3500-C Generator is engineered with features designed for reliability and user convenience:
- Fonte di alimentazione versatile: Suitable for a wide range of applications including construction, agriculture, garden, leisure, and lighting.
- Volume automaticotage Regolamento (AVR): Ensures a stable power output, making it suitable for sensitive equipment and appliances with high starting currents.
- Protezione del motore: Features automatic shutdown in case of low oil and protection against water and foreign object ingress for enhanced operational safety.
- Prestazioni costanti: Designed to deliver constant power output even during prolonged periods of operation.
- Costruzione durevole: High load capacity winding due to the use of high-conductivity copper wire, ensuring longevity and efficiency.
4. Impostazione
Before starting your AL-KO 3500-C Generator, follow these setup steps carefully:
4.1 Disimballaggio e ispezione
- Remove the generator from its packaging and inspect for any shipping damage. Report any damage to your dealer immediately.
- Assicurarsi che tutti i componenti elencati nella lista di imballaggio siano presenti.
4.2 Posizionamento
- Posizionare il generatore su una superficie solida e piana.
- Ensure the generator is in a well-ventilated outdoor area, far from windows, doors, and vents to prevent carbon monoxide accumulation.
- Maintain at least 1 meter (3 feet) of clearance around the generator for proper airflow.
4.3 Carburante e olio
- Aggiungere olio motore: The generator is shipped without engine oil. Fill the crankcase with the recommended oil type (refer to the specifications section or engine label) to the appropriate level using the dipstick. Do not overfill.
- Aggiungere carburante: Fill the fuel tank with fresh, unleaded gasoline. Do not use old or contaminated fuel. Do not overfill the tank; leave space for fuel expansion. Ensure the fuel cap is securely tightened.
5. Istruzioni per l'uso
Follow these steps to safely start and operate your AL-KO 3500-C Generator:
5.1 Lista di controllo pre-avvio
- Controllare il livello dell'olio motore.
- Controllare il livello del carburante.
- Ensure all connected appliances are unplugged from the generator outlets.
- Verify the generator is on a level surface in a well-ventilated outdoor area.
5.2 Avviamento del motore
- Ruotare l'interruttore del motore in posizione 'ON'.
- Aprire la valvola del carburante.
- Spostare la leva dello starter in posizione 'CHOKE' (se il motore è freddo).
- Pull the recoil starter handle slowly until resistance is felt, then pull firmly and quickly. Repeat if necessary.
- Una volta avviato il motore, spostare gradualmente la leva dello starter in posizione "RUN".
- Lasciare riscaldare il motore per qualche minuto prima di collegare i carichi elettrici.
5.3 Collegamento dei carichi elettrici
- Plug in the appliances one by one, starting with the highest wattage dispositivo.
- Do not overload the generator. Refer to the generator's maximum power output in the specifications.
- Monitor the indicator lights on the control panel.

Image 5.1: Close-up of the AL-KO 3500-C Generator control panel, showing outlets, circuit breakers, and indicator lights.
5.4 Spegnimento del generatore
- Unplug all electrical appliances from the generator outlets.
- Lasciare funzionare il generatore per alcuni minuti senza carico per farlo raffreddare.
- Portare l'interruttore del motore in posizione "OFF".
- Chiudere la valvola del carburante.
6. Manutenzione
Regular maintenance is crucial for the longevity and reliable operation of your AL-KO 3500-C Generator. Always perform maintenance with the engine off and cool.
6.1 Programma di manutenzione
| Articolo | Prima di ogni utilizzo | Ogni 25 ore / Mensile | Ogni 100 ore / Annualmente |
|---|---|---|---|
| Olio motore | Controlla il livello | Modifica | |
| Filtro dell'aria | Pulito | Sostituire | |
| Candela | Ispezionare / Pulire | Sostituire | |
| Filtro del carburante | Ispezionare/sostituire |
6.2 Conservazione
- For long-term storage (over 30 days), drain the fuel tank and carburetor to prevent fuel degradation.
- Store the generator in a clean, dry, and well-ventilated area, away from direct sunlight and extreme temperatures.
- Coprire il generatore per proteggerlo da polvere e umidità.
7. Risoluzione Dei Problemi
This section addresses common issues you might encounter with your AL-KO 3500-C Generator.
7.1 Il motore non si avvia
- Nessun carburante: Controllare il livello del carburante e aggiungere benzina fresca se necessario.
- Engine Switch OFF: Assicurarsi che l'interruttore del motore sia in posizione "ON".
- Fuel Valve Closed: Aprire la valvola del carburante.
- Posizione di strozzamento: Adjust the choke lever correctly for a cold or warm engine.
- Basso livello dell'olio: The generator has an automatic low oil shutdown. Check the oil level and add oil if necessary.
- Candela: Inspect the spark plug. Clean or replace if it is fouled or damaged.
7.2 Nessuna potenza in uscita
- L'interruttore automatico è scattato: Check the AC circuit breakers on the control panel and reset them if tripped.
- Sovraccarico: Reduce the total load connected to the generator.
- Collegamenti allentati: Assicurarsi che tutti i cavi di alimentazione siano saldamente collegati alle prese del generatore.
If you encounter issues not covered here or if troubleshooting steps do not resolve the problem, contact AL-KO customer support or a qualified service technician.
8. Specifiche
Technical specifications for the AL-KO 3500-C Generator (Model Number: 130931):
| Specificazione | Valore |
|---|---|
| Produttore | AL-KO |
| Dimensioni del prodotto (L x P x A) | Dimensioni: 59 x 43 x 48 cm |
| Numero modello articolo | 130931 |
| Colore | Rosso |
| Tipo di carburante | Benzina |
| Voltage | 230 Volt |
| Potenza di uscita (nominale) | 2.8 kW |
| Potenza in uscita (massima) | 3.1 kW |
| Tipo di motore | 4 tempi |
| Cilindrata del motore | 212 cm³ |
| Capacità del serbatoio del carburante | 15 litri |
| Massimo Tempo di operatività | 10.5 ore |
| Max. Sound Power Level | 96 dB(A) |
| Peso dell'articolo | 50 chilogrammi |
| Componenti inclusi | Unità generatore |
| Batteria/e inclusa/e | NO |
| Batteria/e richiesta/e | NO |
| Disponibilità dei pezzi di ricambio | Informazioni non disponibili |
9. Garanzia e supporto
AL-KO stands by the quality of its products.
9.1 Estensione della garanzia
You can extend your product warranty by an additional 2 years (total 2+2 years) by registering your AL-KO 3500-C Generator online. Visit www.alko-garden.de for online registration and more details on warranty terms.

Image 9.1: AL-KO 2+2 Years Warranty Extension badge, indicating extended warranty upon online registration.
9.2 Assistenza clienti
For technical assistance, spare parts, or warranty claims, please contact AL-KO customer support through their official website or your local dealer. Always have your model number (3500-C) and item model number (130931) ready when contacting support.