1. Introduzione
This instruction manual provides essential information for the safe and correct installation, operation, and maintenance of the Danfoss 018F4120 GP Coil with Junction Box. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and to prevent potential hazards.
2. Informazioni sulla sicurezza
AVVERTIMENTO: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect power before installation or maintenance.
- Always ensure the power supply matches the coil's voltage rating (230V).
- Do not operate the coil if it appears damaged.
- Assicurarsi che tutti i collegamenti elettrici siano sicuri e adeguatamente isolati.
- Rispettare tutti i codici e le normative elettriche locali e nazionali.
3. Prodotto finitoview
The Danfoss 018F4120 GP Coil is a 230V power supply coil designed for various industrial electrical applications. It features an integrated junction box for secure electrical connections and protection. This coil is an essential component for controlling solenoid valves or similar devices requiring an electrical signal for activation.

Figura 1: Danfoss 018F4120 GP Coil with Junction Box. This image displays the metallic housing of the coil and the separate metallic cover for the junction box. A black O-ring seal is visible, indicating its use for sealing electrical connections within the junction box, ensuring environmental protection.
4. Configurazione e installazione
Installation should only be carried out by a qualified electrician or technician.
- Disconnessione dell'alimentazione: Ensure all power to the circuit is disconnected before beginning installation. Verify with a voltagetester.
- Montaggio: Securely mount the coil onto the intended device (e.g., solenoid valve stem) according to the device's specifications. The coil should fit snugly and be properly aligned.
- Cablaggio:
- Aprire il coperchio della scatola di giunzione.
- Route the power supply wires through the appropriate cable glands into the junction box.
- Connect the 230V AC power supply wires to the designated terminals within the junction box. Refer to the wiring diagram (if provided with the specific device).
- Ensure all connections are tight and free from loose strands.
- Utilize the O-ring seal (as shown in Figure 1) to maintain the ingress protection rating of the junction box.
- Junction Box Closure: Carefully close and secure the junction box cover, ensuring the seal is properly seated to protect against dust and moisture.
- Controllo finale: Before restoring power, visually inspect all connections and mounting for correctness and security.
5. Istruzioni per l'uso
The Danfoss 018F4120 GP Coil operates by converting electrical energy into a magnetic field, which in turn actuates a connected device, typically a solenoid valve.
- Accensione: Una volta completata e verificata l'installazione, ripristinare l'alimentazione al circuito.
- Attivazione: When 230V AC is applied to the coil terminals, the coil will energize, creating a magnetic field. This magnetic field will pull the armature of the connected device (e.g., solenoid valve), changing its state (e.g., opening or closing the valve).
- Disattivazione: When the 230V AC power supply is removed from the coil, the magnetic field collapses, allowing the armature of the connected device to return to its original state, typically by spring force.
- Funzionamento continuo: The coil is designed for continuous duty within its specified temperature range. Avoid operating the coil outside of its rated voltage or temperature limits.
6. Manutenzione
The Danfoss 018F4120 GP Coil is designed for minimal maintenance. However, periodic checks can help ensure long-term reliability.
- Ispezione visiva: Regularly inspect the coil and junction box for any signs of physical damage, corrosion, or loose connections.
- Pulizia: Keep the coil and junction box free from excessive dust, dirt, or moisture. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
- Integrità della connessione: Periodically check the tightness of electrical connections within the junction box. Ensure the junction box cover and seal are intact.
- Condizioni ambientali: Ensure the operating environment remains within the coil's specified temperature and humidity limits.
7. Risoluzione Dei Problemi
If the coil or connected device is not functioning as expected, consider the following troubleshooting steps:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Coil does not energize/device does not activate | Nessuna alimentazione Vol non correttotage Collegamento del cablaggio allentato Bobina danneggiata | Check power supply to the circuit. Verify 230V AC at coil terminals. Ispezionare e serrare tutti i collegamenti elettrici. Replace the coil if damaged (after verifying power and connections). |
| Coil overheats | Sovravoltage Continuous operation in high ambient temperature Incorrect coil for application | Verificare alimentazione voltage. Ensure ambient temperature is within specifications. Confirm coil is suitable for the application and duty cycle. |
| Junction box not sealing properly | O-ring danneggiato Improperly seated cover | Inspect and replace O-ring if damaged. Ensure cover is correctly aligned and securely fastened. |
Se le procedure di risoluzione dei problemi non risolvono il problema, contattare un tecnico qualificato o l'assistenza Danfoss.
8. Specifiche
- Marca: Danfoss
- Numero modello: 018F4120
- Voltage: 230 V CA
- Peso dell'articolo: 1.12 libbre (circa)
- Dimensioni della confezione: 2 x 2 x 2 pollici (circa)
- Produttore: CAI - DANFOSS
- Codice UPC: 696334325713
- Applicazione: General Purpose (GP)
9. Garanzia e supporto
Per informazioni sulla garanzia e supporto tecnico, fare riferimento al sito ufficiale Danfoss website or contact your authorized Danfoss distributor. Keep your purchase receipt for warranty claims.
Danfoss Ufficiale Websito: Visit the Danfoss Store on Amazon