1. Introduzione
The Enersys NP7-12 is a 12V 7Ah sealed lead acid battery designed for reliable power delivery in various applications. Utilizing proven gas recombination technology, these batteries eliminate the need for regular water addition, offering maintenance-free operation and flexibility in usage. This manual provides essential information for the safe and effective use, installation, and maintenance of your Enersys NP7-12 batteries.

Figure 1: Two Enersys NP7-12 12V 7Ah Sealed Lead Acid Batteries.
2. Informazioni sulla sicurezza
Always observe the following safety precautions when handling, installing, or maintaining sealed lead acid batteries:
- Protezione degli occhi: Quando si lavora con le batterie, indossare sempre protezioni per gli occhi adeguate (occhiali di sicurezza o maschere).
- Protezione della pelle: Wear gloves to protect hands from potential acid exposure, although these are sealed batteries, caution is advised.
- Ventilazione: Ensure adequate ventilation when charging batteries to dissipate any gases that may be produced.
- Cortocircuiti: Avoid short-circuiting battery terminals. This can cause severe burns, fire, or explosion. Do not place tools or metal objects on top of the battery.
- Ricarica: Use only chargers specifically designed for sealed lead acid batteries with appropriate voltage and current ratings. Overcharging can damage the battery and pose a safety risk.
- Disposizione: Do not dispose of batteries in fire. Batteries contain lead and sulfuric acid and must be recycled according to local regulations.
- Danno: Do not use batteries that show signs of damage, swelling, or leakage.
3. Configurazione e installazione
Proper setup ensures optimal performance and longevity of your Enersys NP7-12 batteries.
- Ispezione: Upon unboxing, inspect the batteries for any physical damage.
- Orientamento: These batteries can be operated in any orientation except continuously inverted. Ensure they are securely placed to prevent movement.
- Connessione: Connect the batteries to your device or charging system. Ensure correct polarity: positive (+) to positive, negative (-) to negative. Loose connections can cause overheating and poor performance.
- Carica iniziale: While batteries typically arrive with a partial charge, a full initial charge is recommended before first use, especially if the batteries have been stored for an extended period.

Figura 2: Parte superiore e laterale view of Enersys NP7-12 batteries, showing terminal configuration.
4. Istruzioni per l'uso
The Enersys NP7-12 batteries are designed for reliable performance. Follow these guidelines for optimal operation:
- Volume di caricatage:
- Float Charge: 13.5 - 13.8V at 25°C (77°F)
- Cyclic Charge: 14.4 - 15.0V at 25°C (77°F)
- Temperatura: Operate batteries within their specified temperature range. Extreme temperatures can affect performance and lifespan.
- Scarico: Avoid deep discharges. Repeated deep discharges can significantly reduce battery lifespan. Recharge batteries promptly after use.
- Magazzinaggio: If storing batteries for an extended period, ensure they are fully charged and stored in a cool, dry place. Periodically recharge them every 3-6 months to prevent self-discharge.
5. Manutenzione
Enersys NP7-12 batteries are maintenance-free in terms of water addition. However, regular checks can help ensure optimal performance:
- Pulizia del terminale: Periodically inspect battery terminals for corrosion. Clean with a wire brush and a mixture of baking soda and water if necessary. Ensure terminals are dry before reconnecting.
- Verifica della connessione: Verify that all connections are tight and secure. Loose connections can lead to resistance, heat buildup, and power loss.
- Ispezione fisica: Regularly check the battery casing for any signs of damage, cracks, or swelling.
- Charging System Check: Ensure your charging system is functioning correctly and providing the appropriate voltage e corrente.
6. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Batteria che non tiene la carica | Undercharging; sulfation; end of life; faulty charger | Assicurare il corretto volume di caricatage and duration. Check charger functionality. Consider battery replacement if old. |
| Basso volumetage uscita | Battery discharged; loose connections; internal damage | Recharge battery. Check and tighten all connections. Inspect for physical damage. |
| Battery overheating during charge | Overcharging; faulty charger; internal short | Disconnect charger immediately. Verify charger voltage. Replace battery if damage is suspected. |
| Durata della batteria ridotta | Frequent deep discharges; improper charging; high operating temperature | Avoid deep discharges. Ensure correct charging parameters. Operate within recommended temperature range. |
7. Specifiche
| Attributo | Valore |
|---|---|
| Marca | Energia |
| Modello | NP7-12 |
| Voltage | 12 Volt (CC) |
| Amprabbia | 7 Amps |
| Capacità della batteria | 7 Amp Ore |
| Composizione delle celle della batteria | Piombo acido sigillato |
| Peso dell'articolo | 5 libbre |
| Dimensioni del pacco | 6.38 x 6.34 x 4.72 pollici |
| Numero di batterie | 2 (as a pair) |
| Usi consigliati | Power Tool, UPS systems, mobility scooters, gate openers, etc. |
8. Garanzia e supporto
For specific warranty information and technical support regarding your Enersys NP7-12 batteries, please refer to the documentation provided with your purchase or contact Enersys directly through their official websito o tramite i canali di assistenza clienti. Conservare la prova d'acquisto per eventuali reclami in garanzia.
Manufacturer: Enersys