1. Introduzione e oltreview
The ELKO EP HRN-55N is a sophisticated electronic relay designed for continuous monitoring of phase sequence and phase loss in three-phase electrical systems. This device is crucial for protecting sensitive equipment, such as motors, pumps, and compressors, from damage caused by incorrect phase rotation or the complete absence of one or more phases. It ensures the correct operation and longevity of machinery by disconnecting the load when an anomaly is detected.
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of the HRN-55N relay. Please read this manual thoroughly before installation and operation to ensure proper functionality and to prevent potential hazards.
Safety Warning: Installation and servicing must be performed by qualified personnel only, in accordance with all local and national electrical codes and regulations. Disconnect all power before working on the device.
Note: No product images or videos were provided for this manual. Please refer to the product packaging or manufacturer's website for visual aids.
2. Configurazione e installazione
2.1 Montaggio
The HRN-55N relay is designed for DIN rail mounting (EN 60715). Ensure the mounting location is free from excessive vibration, moisture, dust, and corrosive gases. Maintain adequate ventilation around the device to prevent overheating.
- Securely attach the DIN rail to a stable surface within an electrical enclosure.
- Clip the HRN-55N relay onto the DIN rail by aligning the bottom clips and pressing the top edge until it locks into place.
2.2 Cablaggio
Before wiring, ensure the main power supply to the circuit is disconnected and locked out. Refer to the wiring diagram typically found on the side of the device or in the product datasheet for precise terminal connections. The HRN-55N typically requires connection to all three phases (L1, L2, L3) and a neutral (N) if applicable, for its monitoring function, and also has output relay contacts (e.g., 15, 16, 18) for controlling the load.
- Connect the three-phase supply lines (L1, L2, L3) to the corresponding input terminals on the HRN-55N.
- If the device requires a neutral connection, connect the neutral line to the designated terminal.
- Connect the load control circuit to the output relay contacts. These contacts are typically Normally Open (NO) and Normally Closed (NC), and a Common (COM) terminal. For most applications, the NO contact is used to energize a contactor coil, which then supplies power to the protected equipment.
- Assicurarsi che tutti i collegamenti siano ben saldi e sicuri per evitare contatti allentati e potenziali archi elettrici.
Important: Incorrect wiring can damage the device or the connected equipment, and poses a severe electrical hazard.
3. Istruzioni per l'uso
Once properly installed and wired, the HRN-55N operates automatically to monitor the phase conditions.
3.1 Power-Up and Initial Operation
- After completing all wiring, restore power to the circuit.
- The HRN-55N will perform a self-check. The status LED (typically green) will illuminate if all phases are present and in the correct sequence.
- If the phase sequence is correct and no phase loss is detected, the output relay will energize (the NO contact will close), allowing power to the protected equipment.
3.2 LED indicatori
The HRN-55N typically features one or more LEDs to indicate its operational status:
- Green LED (Power/Status):
- Solid ON: All phases present, correct sequence, relay energized.
- OFF: No power, or internal fault.
- Flashing: (Specific to model, may indicate a delay or specific fault condition).
- Red LED (Fault/Error): (Se presente)
- Solid ON: Phase loss or incorrect phase sequence detected, relay de-energized.
3.3 Phase Sequence and Loss Detection
The HRN-55N continuously monitors the voltage and phase angle of each connected phase. If the phase sequence (L1-L2-L3) is incorrect, or if any phase voltage drops below a preset threshold (phase loss), the relay will immediately de-energize its output contacts, thereby protecting the connected load. The relay will automatically reset and re-energize once the correct phase conditions are restored.
4. Manutenzione
The ELKO EP HRN-55N relay is designed for long-term, maintenance-free operation. However, periodic inspection of the installation environment is recommended.
- Pulizia: Ensure the device is free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
- Connessioni: Periodically check terminal connections for tightness, especially in environments with vibration. Loose connections can lead to overheating and malfunction.
- Condizioni ambientali: Verificare che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.
Note: There are no user-serviceable parts inside the HRN-55N. Do not attempt to open or repair the device. Doing so will void the warranty and may pose a safety risk.
5. Risoluzione Dei Problemi
If the HRN-55N is not functioning as expected, refer to the following troubleshooting guide:
| Sintomo | Possibile causa | Soluzione |
|---|---|---|
| Device has no power (LEDs off). | Nessun volume in ingressotage; incorrect wiring; blown fuse in supply circuit. | Controllare l'input voltage at terminals; verify wiring against diagram; check and replace fuses. |
| Green LED off, Red LED (if present) on, or relay not energizing. | Incorrect phase sequence; phase loss detected; voltage fuori dal range operativo. | Verify phase sequence (L1, L2, L3) at input terminals; check for missing phases; measure line voltages. Correct any issues. |
| Relay cycles on/off rapidly. | Vol. ingresso instabiletage; intermittent phase loss. | Check power supply stability; inspect wiring for loose connections; consult with an electrician to diagnose power quality issues. |
| Relay energized, but load not receiving power. | Fault in load circuit; contactor coil failure; wiring error to load. | Check the load circuit and contactor; verify wiring from HRN-55N output to contactor coil. |
If the problem persists after following these steps, contact ELKO EP technical support or a qualified electrician.
6. Specifiche
The following are typical specifications for the ELKO EP HRN-55N. Refer to the specific product datasheet for exact values, as specifications may vary slightly by production batch or region.
- Funzione: Phase sequence and phase loss monitoring
- Volume di fornituratage: 3x 400V AC (L1, L2, L3) or 3x 230V AC (L1, L2, L3) depending on model variant.
- Frequenza: Frequenza 50/60 Hz
- Contatto di uscita: 1x Changeover (SPDT) relay, typically 8A / 250V AC (resistive load)
- Temperatura di esercizio: Da -20°C a +55°C (da -4°F a +131°F)
- Temperatura di conservazione: Da -30°C a +70°C (da -22°F a +158°F)
- Grado di protezione: IP20 (terminals), IP40 (front panel)
- Montaggio: Guida DIN EN 60715
- Dimensioni (L x A x P): Approximately 90 x 17.6 x 64 mm (1-module width)
- Peso: Circa 60 g
7. Informazioni sulla garanzia
ELKO EP products are manufactured to the highest quality standards. This product is covered by a standard manufacturer's warranty against defects in materials and workmanship for a period typically specified at the point of purchase or on the official ELKO EP website. The warranty does not cover damage resulting from improper installation, misuse, unauthorized modification, or natural disasters.
For detailed warranty terms and conditions, please refer to the official ELKO EP warranty policy available on their websito o contattare il distributore locale.
8. Supporto e contatto
For technical assistance, product inquiries, or support regarding the ELKO EP HRN-55N relay, please contact your authorized ELKO EP distributor or visit the official ELKO EP websito.
ELKO EP Official Websito: www.elkoep.com
Please have your product model number (HRN-55N) and any relevant details about your installation or issue ready when contacting support.