Corso MSA 801582

MSA Safety 801582 SampManuale di istruzioni del filtro Water Stop Probe Passport

Modello: 801582

1. Introduzione

This instruction manual provides essential information for the proper installation, operation, and maintenance of the MSA Safety 801582 Sample Probe Passport Water Stop Filter. This product is designed to prevent water ingress into gas detection equipment, ensuring accurate readings and protecting sensitive internal components. Please read this manual thoroughly before use to ensure safe and effective operation.

2. Prodotto finitoview e componenti

The MSA Safety 801582 Water Stop Filter is a critical accessory for sample probe systems, designed to halt the flow of water and protect connected instruments. Each pack contains 10 individual filters.

Pack of 10 MSA Safety 801582 Water Stop Filters

Figura 1: A pack of ten MSA Safety 801582 Sample Probe Passport Water Stop Filters. These filters are designed to prevent water from entering gas detection equipment.

Each filter unit consists of a durable plastic housing with inlet and outlet ports, containing a specialized membrane or material that stops water while allowing gas samples to pass through. The compact design facilitates easy integration into existing sample linee.

Close-up of a single MSA Safety 801582 Water Stop Filter

Figura 2: Un dettagliato view of a single MSA Safety 801582 Water Stop Filter, showing its clear plastic body and connection ports. The filter is marked with "ADVANTEC JP050AN".

3. Configurazione e installazione

Proper installation is crucial for the effective performance of the water stop filter. Follow these steps carefully:

  1. Identificare i punti di connessione: Determinare la sample line where water ingress is a potential issue. The filter should be installed between the sample probe and the gas detection instrument.
  2. Garantire la compatibilità: Verify that the filter's connection ports are compatible with your existing sample tubing. The filter is designed for use with MSA Passport systems.
  3. Orientamento corretto: Observe the flow direction indicated on the filter body (if present) or ensure the filter is positioned to intercept water before it reaches the instrument. Typically, the wider end connects to the sample source, and the narrower end to the instrument.
  4. Connessioni sicure: Collegare la sample tubing securely to both the inlet and outlet ports of the filter. Ensure all connections are tight to prevent leaks, which could compromise sample integrity or filter effectiveness.
  5. Sistema di test: After installation, perform a system leak test according to your gas detection equipment's manual to confirm proper sealing and functionality.

Warning: Do not force connections. Incorrect installation can lead to leaks or damage to the filter and connected equipment.

4. Istruzioni per l'uso

Once installed, the MSA Safety 801582 Water Stop Filter operates passively as part of your sample line. It requires no active user input during normal operation.

  • Monitoraggio continuo: The filter continuously prevents water from reaching your gas detection sensor while allowing the gas sample to pass through.
  • Ispezione visiva: Periodically inspect the transparent body of the filter for any signs of accumulated water or discoloration, which indicates the filter is performing its function and may require replacement.
  • Limitazione del flusso: A significant accumulation of water or particulate matter within the filter may cause a noticeable restriction in sample flow. This is an indication that the filter needs immediate replacement.

5. Manutenzione

The MSA Safety 801582 Water Stop Filter is a disposable component and is not designed for cleaning or reuse. Regular inspection and timely replacement are the primary maintenance activities.

  • Frequenza di ispezione: Inspect the filter daily or before each use, especially in environments where water exposure is likely.
  • Sostituzione: Replace the filter immediately if:
    • Water is visible inside the filter housing.
    • There is a noticeable reduction in sampil flusso.
    • The filter material appears discolored or damaged.
    • The filter has been exposed to a significant amount of moisture.
  • Disposizione: Dispose of used filters according to local regulations for industrial waste.
  • Magazzinaggio: Store unused filters in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures.

6. Risoluzione Dei Problemi

Problema Possibile causa Soluzione
Reduced sample flow to instrument Filter is clogged with water or particulate matter. Replace the water stop filter.
Water detected in gas detection instrument Filter is compromised or improperly installed. Inspect filter for damage. Ensure connections are secure. Replace filter if necessary.
Filter appears discolored or damaged Exposure to harsh chemicals or physical stress. Sostituire immediatamente il filtro.

7. Specifiche

Caratteristica Dettaglio
Numero di modello 801582
Tipo di prodotto Sample Probe Passport Water Stop Filter
Marca Sicurezza MSA
Materiale Durable Plastic (Filter Body), Stainless Steel (Internal/Connectors - as per manufacturer specifications)
Dimensioni del prodotto 3 x 2 x 0.1 inches (approximate, individual filter)
Peso dell'articolo 0.48 ounces (individual filter)
Conteggio unità 10 filtri per confezione
Certificazione di test esterni CE
Codice UPC 641817010266
Beneficio primario Prevents water ingress, reduces PFAS (as per product benefits)

8. Garanzia e supporto

For specific warranty information regarding the MSA Safety 801582 Sample Probe Passport Water Stop Filter, please refer to the documentation provided with your original purchase or contact MSA Safety directly. As a consumable item, filters typically have a limited warranty against manufacturing defects.

For technical support, product inquiries, or to purchase replacement filters, please visit the official MSA Safety websito o contattare il servizio clienti. Puoi trovare maggiori informazioni sul sito MSA Safety Store on Amazon o la loro azienda websito.

Documenti correlati - 801582

Preview Manuale operativo del software MSA A2: Controllo di responsabilità
Manuale operativo completo per il software MSA A2, un sistema di controllo della responsabilità progettato per il monitoraggio in tempo reale di apparecchiature di sicurezza come autorespiratori e dispositivi correlati in operazioni critiche. Descrive la configurazione, l'utilizzo e le funzionalità per una migliore gestione della sicurezza.
Preview Manuale utente del dispositivo indossabile per il rilevamento di gas MSA ALTAIR io 4
Questa guida per l'utente fornisce istruzioni complete per il dispositivo indossabile per il rilevamento di gas MSA ALTAIR io 4, che trattano avvisi di sicurezza, configurazione, funzionamento, caratteristiche, manutenzione e risoluzione dei problemi.
Preview Manuale operativo del software MSA A2: Controllo di responsabilità
Comprehensive operating manual for MSA A2 Software, detailing its features for real-time accountability control and monitoring of SCBA and personnel during critical operations.
Preview Manuale d'uso del casco protettivo MSA F2 X-TREM
Il casco MSA F2 X-TREM è un casco protettivo versatile progettato per diverse applicazioni, tra cui la lotta agli incendi boschivi, le operazioni di soccorso e l'alpinismo. Questo manuale utente fornisce informazioni essenziali sul corretto utilizzo, la regolazione, la manutenzione e gli accessori disponibili, garantendo sicurezza e prestazioni ottimali.