Leviton GFTA2-W

Leviton GFTA2-W 20 Amp GFCI Outlet with Audible Alarm and Self-Test: Instruction Manual

Model: GFTA2-W | Brand: Leviton

1. Informazioni sul prodotto

The Leviton GFTA2-W is a 20 Amp Ground Fault Circuit Interrupter (GFCI) outlet designed to enhance electrical safety in your home. This device continuously monitors electrical current and quickly interrupts power if a ground-fault is detected, protecting against electric shock and electrocution. It features an audible alarm to alert users to power loss, particularly useful for appliances in less frequently visited areas like garages or basements. The GFTA2-W also includes an automatic self-test function and an LED indicator for continuous monitoring of its operational status, ensuring compliance with National Electric Code® (NEC®) standards.

Caratteristiche principali:

2. Contenuto della confezione

3. Informazioni sulla sicurezza

AVVERTIMENTO: To avoid fire, shock, or death, turn OFF power at the circuit breaker or fuse box and test that power is OFF before wiring! This device must be installed in accordance with all national and local electrical codes.

4. Installazione

Follow these general steps for installing your Leviton GFCI outlet. Always refer to the detailed wiring diagrams provided with your product packaging for specific instructions.

  1. Spegnimento dell'alimentazione: Locate your circuit breaker panel and turn off the power to the circuit where you will be installing the GFCI outlet. Use a voltage tester to confirm that the power is completely off at the outlet box.
  2. Rimuovere la vecchia presa: Carefully remove the wall plate and unscrew the existing outlet from the electrical box. Gently pull the old outlet out of the box.
  3. Scollegare i fili: Disconnect the wires from the old outlet. Pay close attention to which wires are connected to the 'LINE' terminals (incoming power) and which are connected to the 'LOAD' terminals (outgoing power to other outlets). Label them if necessary.
  4. Preparare i cavi: Ensure the ends of the wires are stripped to the appropriate length (usually 1/2 inch or 12.7 mm) as indicated by the strip gauge on the back of the new GFCI device.
  5. Collegare il filo di terra: Connect the bare copper or green insulated ground wire from the electrical box to the green ground screw on the GFCI outlet. Tighten securely.
  6. Collegare i fili LINE: Connect the incoming power (LINE) wires from the electrical box to the 'LINE' terminals on the GFCI outlet. The white wire connects to the silver 'LINE' terminal, and the black wire connects to the brass 'LINE' terminal. Ensure these connections are tight.
  7. Collegare i cavi di CARICO (facoltativo): If you are protecting downstream outlets, connect the outgoing power (LOAD) wires to the 'LOAD' terminals. The white wire connects to the silver 'LOAD' terminal, and the black wire connects to the brass 'LOAD' terminal. If no downstream protection is needed, cap the LOAD wires individually with wire nuts.
  8. Mount Outlet: Carefully fold the wires into the electrical box and secure the GFCI outlet to the box with the provided screws.
  9. Installa la piastra a muro: Attach the new wall plate.
  10. Ripristina alimentazione: Riattivare la corrente tramite l'interruttore automatico.

Installation Visual Aids:

Indietro view of Leviton GFCI outlet with wiring terminals

Immagine: Indietro view of the Leviton GFCI outlet, showing the silver and brass wiring terminals for line and load connections, along with the green ground screw.

Davanti view of Leviton GFCI outlet with test and reset buttons

Immagine: Frontale view of the Leviton GFCI outlet, featuring the prominent TEST and RESET buttons and the LED indicator light.

Leviton GFCI outlet installed in a wall

Image: A white Leviton GFCI outlet neatly installed in a wall, ready for use.

Video: Official Leviton guide demonstrating the easy installation process of a GFCI outlet, highlighting its slim profile for more space in the wall box.

5. Istruzioni per l'uso

Funzione di autotest:

Your Leviton GFCI outlet is equipped with an automatic self-test feature that periodically checks its internal components to ensure it is functioning correctly. This occurs without user intervention. Additionally, you should manually test the device monthly.

Indicatore LED:

Allarme acustico:

The audible alarm will sound if the GFCI trips and power is lost to the outlet. This feature is particularly useful for appliances in out-of-the-way locations, such as a garage or basement, where a visual check of the LED indicator might be missed. The alarm helps you quickly identify and address power interruptions to critical appliances like refrigerators.

Leviton GFCI outlet in a garage with an audible alarm icon

Image: An installed Leviton GFCI outlet in a garage setting, with an icon indicating its audible alarm feature, emphasizing its utility for monitoring appliances.

6. Manutenzione

To ensure continued protection, manually test your GFCI outlet monthly:

  1. Spina alamp or radio into the GFCI outlet and turn it on.
  2. Press the 'TEST' button on the GFCI. The lamp/radio should turn off, and the GFCI's LED indicator should change (e.g., turn off or red), and the audible alarm should sound.
  3. Press the 'RESET' button. The lamp/radio should turn back on, and the LED indicator should return to green.

If the GFCI does not trip when the 'TEST' button is pressed, or if it does not reset, it may be faulty and should be replaced immediately. Also, perform a visual inspection for any discoloration or loose connections.

7. Risoluzione Dei Problemi

If your GFCI outlet trips (power is interrupted and the LED indicator changes/alarm sounds), follow these steps:

  1. Inspect the GFCI: Check the GFCI outlet for any signs of discoloration, damage, or loose plug connections. If any are found, replace the GFCI immediately.
  2. Identificare la causa: Note what was happening when the GFCI tripped. Were you using a specific appliance? Did you plug something in or turn something on?
  3. Check Appliances/Cords: Visually inspect the appliance and its cord that was connected to the GFCI (or any downstream outlets) for frayed wires, damage, or faults. Unplug any device with obvious damage.
  4. Reimpostare il GFCI: Press the 'RESET' button firmly. If the GFCI resets and holds, the issue might have been temporary or with the unplugged device.
  5. Viaggio persistente: If the GFCI continues to trip, or if the reason for the trip is not obvious after inspecting devices, it's time to contact a qualified electrician.

Video: Leviton's Answer Series explaining what to do when your GFCI outlet trips, including when to contact an electrician.

8. Specifiche

CaratteristicaDettaglio
Dimensioni del prodotto1.7 x 1.3 x 4.2 pollici
Peso dell'articolo5.6 once
ProduttoreLevitone
Numero modello articoloGFTA2-W
MarcaLevitone
ColoreBianco
Dispositivi compatibiliTutto
MaterialePolicarbonato (PC)
Voltage125 Volt

9. Garanzia e supporto

For warranty information, technical support, or further assistance, please contact Leviton customer service directly or visit their official webluogo. Conserva la ricevuta di acquisto per eventuali richieste di garanzia.

Documenti correlati - GFTA2-W

Preview Guida all'installazione e al collaudo della presa GFCI Leviton SmartlockPro
Guida completa all'installazione e al collaudo delle prese GFCI (Ground Fault Circuit Interrupter) Leviton SmartlockPro. Illustra le precauzioni di sicurezza, il cablaggio, la risoluzione dei problemi e le caratteristiche del prodotto.
Preview Guida all'installazione e al collaudo della presa GFCI Leviton
Una guida completa su come installare e testare una presa GFCI Leviton SmartLock Pro, comprese istruzioni di cablaggio, precauzioni di sicurezza e suggerimenti per la risoluzione dei problemi.
Preview Guida all'installazione della presa GFCI per montaggio su guida DIN Leviton GFNT1-DIN/GFNT2-DIN
Guida completa per l'installazione e il collaudo delle prese GFCI per montaggio su guida DIN GFNT1-DIN e GFNT2-DIN di Leviton, comprese istruzioni di cablaggio, precauzioni di sicurezza e risoluzione dei problemi.
Preview Installazione e test della presa GFCI intelligente Leviton: una guida completa
Istruzioni dettagliate per l'installazione e il collaudo delle prese GFCI Leviton Smart (modelli D2GF1, D2GF2). Scopri di più sulla funzionalità GFCI, sul cablaggio, sulla risoluzione dei problemi e sulle precauzioni di sicurezza.
Preview Manuale di installazione e funzionamento della presa GFCI Leviton con porte USB
Guida completa per l'installazione e il funzionamento delle prese GFCI Leviton con porte USB, comprese istruzioni di cablaggio, avvertenze di sicurezza, procedure di collaudo e informazioni sulla garanzia.
Preview Guida introduttiva alla presa Leviton Decora Smart Z-Wave (ZW15R)
Guida completa all'installazione, alla configurazione e alla personalizzazione di Leviton Decora Smart Z-Wave TampPresa elettrica resistente agli urti (ZW15R). Scopri le funzionalità Z-Wave, l'inclusione in rete e le informazioni sulla sicurezza.