Emerson 3L11-325

Manuale utente del termostato a disco a scatto Emerson 3L11-325 da 1/2 pollice

Modello: 3L11-325 | Marca: Emerson

1. Introduzione

The Emerson 3L11-325 is a 1/2-inch bimetal disc thermostat designed for use in various appliances and HVAC systems. This device operates as an 'open on rise' thermostat, meaning its electrical contacts open when the temperature reaches its set range. It features a temperature range of 315 to 335 degrees Fahrenheit and is equipped with 1/4 inch quick connect terminations for easy installation. The thermostat includes a loose ring, stainless steel mounting brackets, and an aluminum disc cup, ensuring reliable performance and automatic reset functionality.

2. Informazioni sulla sicurezza

WARNING: Electrical shock hazard. Disconnect power before installation or servicing. Installation should be performed by a qualified technician.

  • Always ensure the power supply to the appliance or HVAC system is completely disconnected before attempting any installation, maintenance, or inspection of the thermostat.
  • Questo prodotto contiene sostanze chimiche che lo Stato della California ritiene possano causare cancro, malformazioni congenite o altri danni riproduttivi (avvertenza ai sensi della Proposta 65). Maneggiare con cura e lavarsi le mani dopo l'uso.
  • Do not operate the thermostat beyond its specified temperature and electrical ratings.
  • Assicurarsi che tutti i collegamenti elettrici siano sicuri e adeguatamente isolati per evitare cortocircuiti o pericoli elettrici.

3. Prodotto finitoview

The Emerson 3L11-325 is a robust bimetal disc thermostat designed for precise temperature control. It is commonly utilized in various heating, ventilation, and air conditioning (HVAC) systems, as well as in a range of appliances where temperature regulation is critical. Its 'open on rise' characteristic makes it suitable for applications requiring a circuit to open when a specific temperature threshold is exceeded.

Emerson 3L11-325 Snap Disc Thermostat, top view

Figura 1: in alto view of the Emerson 3L11-325 Snap Disc Thermostat, showing the metal disc and mounting tabs.

Caratteristiche principali:

  • Termostato a disco bimetallico per applicazioni HVAC e per elettrodomestici.
  • "Open on Rise" operation: contacts open when temperature increases.
  • Intervallo di temperatura: da 315°C a 335°C (da 157°F a 168°F).
  • Equipped with loose ring, stainless steel mounting brackets, and aluminum disc cup.
  • Features 1/4 inch quick connect terminations for electrical connections.
  • Funzionalità di ripristino automatico.

4. Configurazione e installazione

Proper installation is crucial for the safe and effective operation of the thermostat. It is strongly recommended that installation be carried out by a qualified professional.

  1. Scollegare l'alimentazione: Before beginning any work, ensure that the main power supply to the appliance or HVAC system is completely turned off at the circuit breaker or fuse box. Verify with a voltagetester.
  2. Posizione di montaggio: Select a mounting location that accurately reflects the temperature to be controlled. The thermostat should be securely mounted using its integrated stainless steel mounting brackets. Ensure good thermal contact with the surface or air stream it is monitoring.
  3. Collegamenti elettrici: Connect the electrical wiring to the 1/4 inch quick connect terminations. Refer to the specific wiring diagram for your appliance or HVAC system. Ensure connections are firm and free from corrosion.
  4. Installazione sicura: Double-check that the thermostat is firmly mounted and all wiring is correctly routed and secured, preventing any accidental disconnections or damage.
  5. Ripristina alimentazione: Una volta completata e verificata l'installazione, ripristinare l'alimentazione del sistema.
Emerson 3L11-325 Snap Disc Thermostat, angled view mostrando i terminali

Figura 2: Angolato view of the Emerson 3L11-325 Snap Disc Thermostat, highlighting the 1/4 inch quick connect terminals.

5. Principi operativi

The Emerson 3L11-325 thermostat operates on a simple yet effective bimetallic principle. Its core component is a bimetal disc, which is a composite of two different metals bonded together, each with a different thermal expansion rate.

  • Normal Operation (Below Set Temperature): When the ambient temperature around the thermostat is below its specified activation range (315-335°F), the bimetal disc remains in its normal, un-flexed state. In this state, the electrical contacts within the thermostat are Chiuso, allowing electrical current to flow through the circuit it controls.
  • Activation (At or Above Set Temperature): As the temperature rises and reaches the 315-335°F range, the bimetal disc heats up. Due to the differing expansion rates of the two metals, the disc rapidly flexes or "snaps" into an inverted position. This snapping action causes the internal electrical contacts to aprire, interrupting the electrical circuit. This is the "open on rise" function.
  • Automatic Reset (Temperature Drops): When the temperature subsequently drops below the thermostat's reset point, the bimetal disc cools down and snaps back to its original position. This action automatically chiude the electrical contacts, restoring the circuit.

This automatic reset feature ensures continuous temperature regulation without manual intervention.

6. Manutenzione

The Emerson 3L11-325 thermostat is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure its continued performance.

  • Ispezione visiva: Annually, or as part of routine appliance/HVAC system maintenance, visually inspect the thermostat for any signs of physical damage, corrosion, or loose connections.
  • Pulizia: Ensure the area around the thermostat is free from dust, debris, or obstructions that could impede proper temperature sensing. Use a soft, dry cloth for cleaning; do not use liquids or abrasive cleaners.
  • Integrità della connessione: Verify that the 1/4 inch quick connect terminations remain securely attached and that wiring insulation is intact.
  • Nessuna parte riparabile dall'utente: The thermostat itself contains no user-serviceable parts. Do not attempt to disassemble or repair the unit. If a malfunction is suspected, the unit should be replaced by a qualified technician.

7. Risoluzione Dei Problemi

If you experience issues with your Emerson 3L11-325 thermostat, consider the following troubleshooting steps. Always ensure power is disconnected before inspecting the unit.

ProblemaPossibile causaSoluzione
Thermostat does not open circuit at high temperature.Unit malfunction; incorrect temperature sensing.Verify ambient temperature. If temperature is within range and contacts remain closed, the unit may be faulty and require replacement.
Thermostat does not close circuit at low temperature.Unit malfunction; contacts stuck open.Verify ambient temperature. If temperature is below reset point and contacts remain open, the unit may be faulty and require replacement.
Operazione intermittente.Loose electrical connections; unstable temperature environment.Check all 1/4 inch quick connect terminations for secure fit. Ensure thermostat is not exposed to rapid temperature fluctuations.
No power to controlled device.Thermostat contacts open; external power issue.Check if ambient temperature is above the thermostat's activation range. Verify main power supply to the system.

If troubleshooting steps do not resolve the issue, consult a qualified technician for further diagnosis and repair or replacement.

8. Specifiche

MarcaEmerson
Numero di modello3L11-325
Tipo di termostatoBimetal Disc, Snap Action
OperazioneOpen on Rise
Intervallo di temperaturada 315°F a 335°F (da 157°C a 168°C)
TerminazioniAttacco rapido da 1/4 di pollice
MontaggioLoose ring, stainless steel mounting brackets
Tipo di ripristinoAutomatico
Peso dell'articoloCirca 0.2 once (0.01 libbre)
Dimensioni del prodotto1.23 x 1.32 x 0.37 pollici
Usi specificiResidential, temperature control, appliances, HVAC systems
Codice UPC786710503719

9. Garanzia e supporto

For detailed warranty information, terms, and conditions related to your Emerson 3L11-325 Snap Disc Thermostat, please refer to the official Emerson website or the documentation provided with your purchase. Keep your proof of purchase, such as a receipt or invoice, as it may be required for warranty claims.

For technical assistance, product inquiries, or to locate authorized service centers, please contact Emerson customer support directly. Contact information can typically be found on the official Emerson websito o sulla confezione del prodotto.

You can visit the official Emerson websito per maggiori informazioni: www.emerson.com

Documenti correlati - 3L11-325

Preview Guida all'installazione e al funzionamento del termostato programmabile per pompa di calore Emerson 1F83H-21PR
Istruzioni complete per l'installazione e l'uso del termostato programmabile per pompa di calore Emerson 1F83H-21PR serie 80. Scopri di più su cablaggio, configurazione, menu utente, programmazione e risoluzione dei problemi.
Preview Manuale di installazione e utilizzo del termostato Emerson Blue Easy Set 1H/1C
Guida completa per il termostato non programmabile Emerson Blue Easy Set 1H/1C, che copre l'installazione, il funzionamento, funzioni come le preimpostazioni della temperatura Casa, Sonno e Fuori, i promemoria del filtro e la risoluzione dei problemi.
Preview Manuale utente per il proprietario di casa del termostato Emerson Blue 1F98EZ-1421/1F98EZ-1441
Manuale d'uso completo per i proprietari di casa per i modelli di termostato Emerson Blue 1F98EZ-1421 e 1F98EZ-1441, che descrive in dettaglio configurazione, programmazione, funzionamento del sistema, diagnostica e manutenzione.
Preview Istruzioni per l'installazione e l'uso del termostato universale Emerson 1F85U-22NP
Guida completa per l'installazione e l'utilizzo del termostato universale Emerson 1F85U-22NP. Illustra la configurazione, le caratteristiche, la risoluzione dei problemi e le specifiche per un controllo ottimale della climatizzazione domestica.
Preview Istruzioni per l'installazione e l'uso del termostato non programmabile Emerson 1F75C-11NP
Istruzioni per l'installazione e l'uso del relè singolo non programmabile Emerson 1F75C-11NPtage Termostato. Copre cablaggio, configurazione, menu di installazione, test e risoluzione dei problemi.
Preview Istruzioni per l'installazione e l'uso del termostato PTAC Emerson 1F75P-21NP
Guida completa per l'installazione e il funzionamento del termostato PTAC non programmabile Emerson 1F75P-21NP. Informazioni su cablaggio, configurazione, funzionalità e risoluzione dei problemi.