Southwire AMMW1

Woods AMMW1 Analog Multimeter Instruction Manual

Model: AMMW1 | Brand: Southwire

1. Introduzione

This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of the Woods AMMW1 Analog Multimeter. Please read this manual thoroughly before using the device and retain it for future reference.

The Woods AMMW1 is a versatile analog multimeter designed for basic electrical measurements, offering 5 functions with up to 16 measuring ranges. It is rated CAT II 500V UL.

2. Informazioni sulla sicurezza

WARNING: To avoid electric shock or personal injury, always follow basic safety precautions when using this instrument.

  • Assicurarsi sempre che i puntali di prova siano in buone condizioni e correttamente collegati.
  • Non tentare di misurare il voltages or currents exceeding the maximum rated values for each range.
  • Always turn off power to the circuit under test before connecting or disconnecting test leads.
  • Siate cauti quando lavorate con voltagsuperiori a 30 V CA RMS, 42 V di picco o 60 V CC, poiché rappresentano un rischio di scossa elettrica.
  • Sostituire la batteria e il fusibile solo con quelli del tipo specificato.
  • Non utilizzare il multimetro se appare danneggiato o se la custodia è aperta.

3. Prodotto finitoview

The Woods AMMW1 Analog Multimeter features a clear analog display and a rotary selector for various measurement functions.

Woods AMMW1 Analog Multimeter front view

Figure 1: Woods AMMW1 Analog Multimeter. This image displays the front of the multimeter, showing the analog display with various scales (OHMS, AC DC, AC10V BATT), the Woods logo, the model number AMMW1, the rotary function selector switch, and the input jacks for VΩmA and COM. An 'ADJUST Ω' knob is visible on the right side, and 'FUSE & DIODE PROTECTION' is indicated below the display.

3.1 componenti chiave

  1. Display analogico: Shows measurement readings using a needle against various scales.
  2. Rotary Function Selector: Used to select the desired measurement function and range (e.g., ACV, DCV, Resistance, Current, Battery Test).
  3. Jack di ingresso VΩmA: Positive (+) input for voltagmisurazioni di e, resistenza e corrente.
  4. Jack di ingresso COM: Common/Negative (-) input for all measurements.
  5. OHMS Adjustment Knob: Utilizzato per azzerare il misuratore per le misurazioni della resistenza.
  6. Battery Test Sockets: Dedicated sockets for testing 1.5V and 9V batteries.

4. Impostazione

4.1 Installazione della batteria

The Woods AMMW1 requires 1 AA battery (included) for operation. To install or replace the battery:

  1. Ensure the multimeter is turned off (selector switch to OFF position, if available, or a non-measurement range).
  2. Individuare il coperchio del vano batterie sul retro dell'unità.
  3. Remove the screw(s) securing the cover and carefully open it.
  4. Insert the AA battery, observing the correct polarity (+ and - markings).
  5. Replace the cover and secure it with the screw(s).

4.2 Collegamento dei puntali di prova

  • Inserire il puntale nero nel COM Jack (comune).
  • Inserire il puntale rosso nel VΩmA jack per la maggior parte delle misurazioni (voltage, resistance, current).

5. Istruzioni per l'uso

Before taking any measurement, ensure the test leads are correctly connected and the rotary selector is set to the appropriate function and range.

5.1 Misurazione del volume CCtage (V-)

  1. Set the rotary selector to the desired DC Voltage (V-) range (e.g., 2.5V, 10V, 50V, 250V, 500V). Choose a range higher than the expected voltage.
  2. Collegare il puntale di prova rosso al lato positivo (+) del circuito e il puntale di prova nero al lato negativo (-).
  3. Leggi il vol.tage value from the appropriate DCV scale on the analog display.

5.2 Misurazione del volume CAtage(V~)

  1. Set the rotary selector to the desired AC Voltage (V~) range (e.g., 10V, 50V, 250V, 500V). Choose a range higher than the expected voltage.
  2. Collegare i puntali di prova attraverso la tensione CAtage fonte.
  3. Leggi il vol.tage value from the appropriate ACV scale on the analog display.

5.3 Misurazione della resistenza (Ω)

  1. Set the rotary selector to the desired Resistance (Ω) range (e.g., 10x Ω, 1000x Ω).
  2. Short the red and black test leads together.
  3. Regolare il OHMS ADJUST knob until the needle points exactly to '0' on the OHMS scale. This zeros the meter.
  4. Collegare i puntali di prova al componente di cui si desidera misurare la resistenza. Assicurarsi che il componente sia diseccitato.
  5. Read the value from the OHMS scale and multiply it by the range multiplier (e.g., x10, x1000).

5.4 Measuring DC Current (mA, µA)

  1. AVVERTIMENTO: Non collegare mai il multimetro in parallelo con un voltmetrotage source when measuring current. Always connect it in series with the circuit.
  2. Set the rotary selector to the desired DC Current (mA or µA) range (e.g., 500 µA, 10 mA, 250 mA).
  3. Interrompere il circuito nel punto in cui si desidera misurare la corrente.
  4. Connect the multimeter in series with the circuit, ensuring the red lead is towards the higher potential and the black lead towards the lower potential.
  5. Leggere il valore corrente sulla scala appropriata.

5.5 Battery Testing (1.5V, 9V)

  1. Set the rotary selector to the 1.5V BATT or 9V BATT posizione.
  2. Insert the battery to be tested into the corresponding battery test sockets, observing polarity.
  3. Read the battery condition from the dedicated "BAD / GOOD" scale on the analog display.

6. Manutenzione

6.1 Pulizia

Pulisci la custodia con l'adamp panno e detergente delicato. Non utilizzare abrasivi o solventi. Mantenere i puntali puliti e privi di detriti.

6.2 Sostituzione del fusibile

The multimeter is equipped with fuse and diode protection. If the current measurement function stops working, the fuse may need replacement.

  1. Assicurarsi che il multimetro sia spento e che i puntali di prova siano scollegati.
  2. Open the back cover of the multimeter (refer to battery installation).
  3. Rimuovere con cautela il vecchio fusibile.
  4. Replace with a fuse of the exact same type and rating (consult the device's internal markings or specifications for fuse type).
  5. Chiudere saldamente il coperchio posteriore.

7. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
No reading / Needle doesn't moveDead battery; Incorrect range selected; Open circuit; Faulty test leads.Check/replace battery; Select appropriate range; Verify circuit continuity; Check test leads for damage.
Letture impreciseIncorrect range; Poor contact; OHMS not zeroed (for resistance).Select a more appropriate range; Ensure good contact with test points; Zero OHMS before resistance measurement.
Misurazione della corrente non funzionanteFusibile bruciato.Sostituire il fusibile (vedere la sezione Manutenzione).

8. Specifiche

  • Modello: AMMW1
  • Marca: Southwire (Woods)
  • Tipo di misurazione: Multimetro analogico
  • Funzioni: 5 (DC Voltage, AC voltage, DC Current, Resistance, Battery Test)
  • Campi di misura: Fino a 16
  • Massimo volume di eserciziotage: CATII 500V
  • Batteria: 1 batteria AA (inclusa)
  • Test batteria: 1.5V, 9V
  • Dimensioni del prodotto: Dimensioni: 21.79 x 12.9 x 5.59 cm
  • Peso dell'articolo: 136 grammi
  • Conformità: UL
  • Codice UPC: 032886958403

9. Garanzia e supporto

For warranty information or technical support, please contact Southwire customer service. Retain your proof of purchase for warranty claims.

Note: Specific warranty terms and contact details may vary by region. Please refer to the packaging or manufacturer's websito per le informazioni più aggiornate.

Documenti correlati - AMMW1

Preview Timer meccanico Woods da 24 ore per esterni con 2 prese - Modelli 50123 e 50124
Manuale utente e specifiche per il timer meccanico Woods da 24 ore per esterni, dotato di due prese con messa a terra. Include istruzioni di installazione, guida alla programmazione, dati elettrici nominali, informazioni sulla garanzia e dettagli sulla conformità FCC per i modelli 50123 (1/2 HP) e 50124 (3/4 HP).
Preview Timer meccanico Woods Outdoor 24 ore con fotocellula - Modelli 50121 e 50122
Manuale d'uso per il timer meccanico Woods da 24 ore per esterni con fotocellula. Include istruzioni di installazione, impostazioni del timer, suggerimenti per la risoluzione dei problemi, specifiche, informazioni sulla garanzia e dettagli sulla conformità FCC per i modelli 50121WD e 50122WD.
Preview Manuale utente della presa di corrente wireless Woods 50125/50125-R
Manuale utente per la presa wireless con telecomando Woods 50125/50125-R. Fornisce istruzioni su installazione, associazione, risoluzione dei problemi, specifiche, avvertenze di sicurezza e informazioni sulla garanzia.
Preview Timer meccanico Woods 50101WD da 24 ore con 1 presa polarizzata: istruzioni per l'uso
Manuale utente per il timer meccanico Woods 50101WD da 24 ore. Fornisce istruzioni dettagliate su impostazione dell'ora, programmazione dei programmi, collegamento dei dispositivi, specifiche, avvertenze, garanzia e conformità FCC per questo timer con presa singola polarizzata.
Preview Manuale dell'operatore del carrello per tubi Southwire Grasshopper
Manuale dell'operatore per il carrello per tubi Southwire Grasshopper, contenente istruzioni dettagliate per il collegamento e lo scollegamento dei tubi, informazioni sulla sicurezza e specifiche del prodotto.
Preview Manuale dell'operatore del carrello per tubi Cricket Southwire
Questo manuale fornisce istruzioni operative, informazioni sulla sicurezza e specifiche del prodotto per il carrello Southwire Cricket Pipe Dolly. Include dettagli di montaggio e informazioni sulla garanzia.