American Lighting ALC2-12-WH

Manuale di istruzioni per American Lighting LED Complete 2 Under Cabinet Fixture ALC2-12-WH

Model: ALC2-12-WH

Introduzione

This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your American Lighting LED Complete 2 Under Cabinet Fixture. This 120-Volt dimmable warm white LED fixture is designed for efficient and uniform lighting in various indoor applications.

American Lighting LED Complete 2 Under Cabinet Fixture

Image: The American Lighting LED Complete 2 Under Cabinet Fixture, a white, rectangular LED light bar with a switch on the front, designed for under-cabinet installation.

Informazioni importanti sulla sicurezza

AVVERTIMENTO:

ATTENZIONE:

Safety warnings and pre-installation notes for LED Complete 2

Image: A page from the installation instructions detailing important safety information, warnings, and pre-installation notes for the LED Complete 2 series.

Configurazione e installazione

The American Lighting LED Complete 2 fixture offers flexible installation options, including direct wire and linking multiple units.

Montaggio dell'apparecchio

  1. Determinare la posizione di ciascun apparecchio. Per le installazioni cablate, collegare i cavi di alimentazione tramite i fori predisposti prima del montaggio.
  2. Utilizzare un cacciavite a croce o una punta per avvitare le viti di montaggio imperdibili e fissare il dispositivo a una superficie di montaggio appropriata.
Mounting diagram for American Lighting LED Complete 2 fixture

Image: Diagram showing the mounting points and rear access door of the fixture. It illustrates how to secure the fixture to a surface using screws.

Connecting Power via Rear Access Door

This method is used for hardwiring the fixture directly to a power source.

  1. The rear access door is located in the center of the back of the fixture housing. It has its own knockout for quick connection to supply wires, foregoing the need to remove the lens cover and open the wiring compartment.
  2. Rimuovere il foro utilizzando un martello o un punzone, quindi allentare la vite che fissa lo sportello di accesso posteriore utilizzando un cacciavite a croce o una punta per cacciavite.
  3. Install the 3/8" cable connector (included) for the supply wire following National Electric Code and local codes through this knockout on the access door. Ensure to use 14AWG or 12AWG wire. AC should be protected by circuit breaker or fuse.
  4. Strip back jacket on supply wires to 3/8" and use push-in connectors inside housing to connect the wires, matching polarity (Black=Black, Hot; White=White, Neutral; Yellow/Green=Bare Wire = Ground) through knockout so that push-in connectors are positioned on the housing side of the access door.
  5. Riposizionare lo sportello di accesso posteriore e serrare la vite di fissaggio. Accertarsi che i cavi non siano pizzicati o danneggiati da nessuna parte dell'alloggiamento o del coperchio.
Rear access door wiring diagram for LED Complete 2

Image: Detailed diagram illustrating the rear access door, knockout, and push-in wire connectors for hardwiring the fixture. It shows how to connect the electrical wires securely.

Interconnecting Fixtures

Multiple fixtures can be linked together for continuous lighting.

Interconnecting via Linking/Jumper Cable

  1. To interconnect nearby fixtures, remove the adjacent port covers and utilize the ALC-EX linking cable (sold separately).
  2. If needed, linking cables can be interconnected to make longer lengths.
Linking multiple LED Complete 2 fixtures with jumper cable

Image: Diagram showing how to link multiple LED Complete 2 fixtures using an inline connector or jumper cable. It illustrates the connection points on the side of the fixtures.

Interconnecting via End-to-End Linking

Per collegare direttamente gli apparecchi tra loro (end-to-end), utilizzare il connettore in linea (incluso con ogni apparecchio) rimuovendo i coperchi delle porte adiacenti e inserendoli completamente.

Direct Wire Junction Box Installation (for ALC-BOX-##)

Questo tipo di installazione è meno comune e in genere viene eseguito solo quando la porta di accesso posteriore non può essere utilizzata.

  1. Open wiring compartment by removing screws and open the end of the fixture cover from housing body.
  2. Punch out whichever knockout is best suited for connection to 120V supply wire.
  3. Install cable connector and connect fixture wires following National Electric Code and/or local building code requirements. Minimum 18AWG solid copper wire. AC lead should be 120V protected by circuit breaker or fuse.
  4. Allega riga voltage supply wires to fixture lead wires with wire nuts/WAGO. White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the fixture lead wire. If your system has no ground wire, consult a qualified electrician before proceeding with the installation.
  5. Non installare in ambienti umidi.
  6. Replace the wiring compartment cover, securing with the existing retaining screws. Note: Be sure that the wires are not pinched or damaged by any part of the housing or the cover.
  7. Follow directions above for mounting fixture.
Direct wire junction box installation diagram

Image: Diagram detailing the direct wire junction box installation for the LED Complete 2 fixture. It shows the components like the junction box, electrical port, and push-in connectors, along with wiring instructions.

Istruzioni per l'uso

Accensione/spegnimento

The fixture is equipped with a switch for basic on/off control. For hardwired installations, the fixture will operate via the wall switch connected to the circuit.

Oscuramento

The American Lighting LED Complete 2 fixture is dimmable. Use a compatible 120V dimmer switch (UL approved) for optimal performance. Refer to the "Compatible Dimmers" section for recommended models.

Compatible dimmers and accessories for LED Complete 2

Image: A page from the product information showing recommended power supplies, accessories, and a table of compatible dimmers from various brands, including model numbers and dimming ranges.

Manutenzione

Pulizia

To clean the fixture, ensure power is disconnected. Use a soft, dry, or slightly damp panno. Non utilizzare prodotti chimici aggressivi, detergenti abrasivi o solventi, poiché potrebbero danneggiare la finitura o i componenti elettrici.

Modulo LED

The LED module within this fixture is not user-serviceable. Do not attempt to open or repair the LED module.

Risoluzione dei problemi

If your American Lighting LED Complete 2 fixture is not functioning as expected, please review i seguenti problemi comuni e le relative soluzioni:

If these steps do not resolve the issue, please contact American Lighting customer support.

Specifiche

Technical Information for ALC2-12-WH
CaratteristicaDettaglio
Numero di modelloALC2-12-WH
Ingresso volumetage120V AC 60Hz
Cosatage4 watt
Luminosità273 lumen
Temperatura del colore (CCT)3000K (bianco caldo)
Indice di resa cromatica (CRI)90+
DimmerabileYes (with compatible 120V dimmers)
Vita quotata35,000 ore
Dimensioni (L x P x A)12.25 x 4 x 0.94 pollici
MaterialePowder Coated Aluminum Housing, Acrylic Lens
Tipo di montaggioSurface Mounted, Under Cabinet
Uso interno/esternoSolo per uso interno
CertificazionicETLus Listed (dry location), ENERGY STAR certified
Technical specifications table for LED Complete 2 series

Image: A page from the product brochure detailing technical specifications for the LED Complete 2 series, including input voltage, CCT, CRI, wattage, lumens, and rated life.

Garanzia

This American Lighting product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronic parts) or, at the discretion of American Lighting, Inc., exchanged for a new or reconditioned product.

This warranty does not cover damage due to improper installation, accident, abuse, misuse, or normal wear and tear. It also does not cover incidental or consequential damages.

For complete warranty terms and conditions, please refer to the official American Lighting websito o contattare l'assistenza clienti.

Assistenza clienti

For technical assistance, warranty claims, or additional information, please contact American Lighting:

Documenti correlati - ALC2-12-WH

Preview Istruzioni per l'installazione delle luci a disco LED American Lighting da 120 V, confezione da 12
Istruzioni di installazione dettagliate per le luci a disco a LED da 120 V di American Lighting (modelli RD6-30-WH-12PK, RD6-5CCT-WH-12PK, QD6-30-WH-12PK, QD6-5CCT-WH-12PK). Include informazioni sulla sicurezza, il contenuto dell'apparecchio, le fasi di installazione e manutenzione.
Preview Guida all'installazione del faretto da incasso American Lighting serie RHYM da 120 V
Istruzioni di installazione complete per il faretto da incasso American Lighting RHYM Series 120V, che riguardano sicurezza, installazione in nuove costruzioni e ristrutturazioni, cablaggio, sostituzione delle lenti ottiche, cura, manutenzione, conformità FCC e garanzia.
Preview Guida all'installazione della luce a disco Spektrum+ da 6" di American Lighting (SPKPL-DISC6-RGBTW-WH)
Istruzioni di installazione dettagliate e informazioni sulla sicurezza per la luce a disco American Lighting Spektrum+ RGB+TW da 6" (modello SPKPL-DISC6-RGBTW-WH). Scopri come installare e controllare in sicurezza questo dispositivo LED intelligente.
Preview Istruzioni per l'installazione della striscia luminosa a LED IP54 TRULUX RGB + bianco regolabile 24V
Guida completa all'installazione della striscia luminosa a LED American Lighting 24V TRULUX RGB + Tunable White IP54 SPTL-RGBTW, che copre sicurezza, disposizione, taglio, collegamento e manutenzione.
Preview 120V MVP 5CCT Puck Light Installation Instructions | American Lighting
Comprehensive installation guide for the American Lighting 120V MVP 5CCT LED Puck Light. Includes safety information, surface and recessed mounting instructions, and power connection details.
Preview Striscia luminosa a LED American Lighting serie RGBW | Alta potenza, bianco caldo 3000K
Scopri la striscia luminosa a LED RGBW Series di American Lighting, che offre un'elevata potenza, una miscelazione dinamica dei colori con bianco caldo 3000K, classificazioni IP54/IP65 e controllo DMX per installazioni di illuminazione versatili. View specifiche e caratteristiche.