The Seametrics FT440P is a sophisticated, microcontroller-based indicator/transmitter designed for precise flow measurement applications. It interfaces seamlessly with pulse output flow sensors to accurately compute and display flow rate and total flow. This device is engineered to generate multiple output signals representing flow, making it a versatile component in industrial and scientific settings.
Specifically, the FT440P model features two scaled pulse outputs, providing enhanced flexibility for integration into various control systems. It also offers a 4-20 mA output, a standard in industrial automation for analog signal transmission. Galvanic isolation is incorporated for most pulse outputs, ensuring robust and reliable operation by preventing unwanted current paths.

Figure 1: Seametrics FT440P Flow Computer. This image displays the white, panel-mount device with a clear digital display showing '0.00' for both flow rate and total. Below the display are four blue buttons for navigation and configuration. On the right side, two black cable glands are visible, indicating connection points for wiring.
2. Configurazione e installazione
Proper installation is crucial for the accurate and reliable operation of the FT440P flow computer. Follow these guidelines for setup:
2.1 Montaggio
- The FT440P is designed for panel mounting. Ensure the mounting surface is flat and stable.
- Cut an appropriate opening in the panel according to the dimensions provided in the product specifications (refer to Section 6).
- Secure the device using the provided mounting hardware, ensuring a snug fit to prevent vibration.
2.2 collegamenti elettrici
All wiring should be performed by qualified personnel and in accordance with local electrical codes.
- Alimentazione elettrica: Connect the loop power supply to the designated terminals. The FT440P is loop-powered, meaning it draws power from the 4-20 mA current loop.
- Ingresso sensore: Connect the pulse output from your flow sensor to the FT440P's sensor input terminals. Ensure correct polarity if applicable.
- Uscite a impulsi: Connect the two scaled pulse outputs to your receiving devices (e.g., PLCs, data loggers).
- Uscita 4-20 mA: Connect the 4-20 mA output to your analog input device.
- Ensure all connections are secure and properly insulated to prevent short circuits or interference.
2.3 Configurazione iniziale
Upon initial power-up, the device may require configuration to match your specific flow sensor and application. Refer to the on-screen prompts and use the navigation buttons (visible below the display in Figure 1) to set parameters such as:
- Flow sensor K-factor (pulses per unit volume)
- Units of measurement (e.g., gallons, liters, cubic meters)
- Scaling for pulse outputs
- Zero and span for 4-20 mA output
3. Istruzioni per l'uso
The FT440P provides real-time flow data and configurable outputs. Understanding its operation is key to leveraging its full capabilities.
3.1 Letture del display
The digital display shows two primary values:
- Linea superiore: Instantaneous Flow Rate (e.g., GPM, LPM).
- In conclusione: Accumulated Total Flow (e.g., Gallons, Liters).
The display may also show status indicators or error codes if applicable.
3.2 pulsanti di navigazione
The four buttons below the display are used for menu navigation and parameter adjustment:
- Freccia sinistra (◀): Typically used to move left in menus or decrease values.
- Freccia su (▲): Used to scroll up through menu options or increase values.
- Freccia giù (▼): Used to scroll down through menu options or decrease values.
- Check Mark (✓): Utilizzato per confermare le selezioni o accedere ai sottomenu.
Consult the detailed programming guide (if available from Seametrics) for specific menu structures and parameter settings.
3.3 Segnali di uscita
- Scaled Pulse Outputs: The FT440P generates two independent pulse outputs, scaled according to your configuration. These pulses represent discrete units of flow and are suitable for totalizing or batching applications.
- Uscita 4-20 mA: This analog output provides a continuous signal proportional to the instantaneous flow rate. 4 mA typically represents zero flow, and 20 mA represents the maximum configured flow rate. This output is ideal for integration with analog control systems or data acquisition systems.
4. Manutenzione
The FT440P is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure optimal performance.
- Pulizia: Keep the display and housing clean using a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the plastic or display.
- Connessioni: Periodically inspect all electrical connections for tightness and signs of corrosion. Re-tighten if necessary.
- Condizioni ambientali: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage to internal components. Protect the device from direct sunlight, excessive dust, and moisture.
- Controllo della calibrazione: While the FT440P itself is a computing device, the accuracy of the system depends on the connected flow sensor. Periodically verify the accuracy of your flow sensor according to its manufacturer's recommendations.
5. Risoluzione Dei Problemi
This section provides solutions to common issues encountered with the FT440P. If the problem persists, contact technical support.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun display o alimentazione | No power supply; incorrect wiring; blown fuse (if applicable) | Verificare collegamenti di potenza e voltage. Check wiring for shorts or breaks. Consult wiring diagram. |
| Incorrect flow rate/total | Incorrect K-factor setting; sensor malfunction; air in line | Verify K-factor in settings. Check flow sensor for proper operation. Ensure no air bubbles are passing through the sensor. |
| Nessuna uscita a impulsi | Incorrect scaling; wiring issue; no flow | Check pulse output scaling settings. Verify wiring to receiving device. Ensure flow is present and sensor is generating pulses. |
| No 4-20 mA output or incorrect reading | Wiring issue; incorrect span/zero setting; receiving device malfunction | Verify 4-20 mA wiring and loop integrity. Check span and zero settings. Test receiving device. |
| I pulsanti non rispondono | Problema software temporaneo; danno fisico | Prova a spegnere e riaccendere il dispositivo. Se il problema persiste, contatta l'assistenza. |
6. Specifiche
Key technical specifications for the Seametrics FT440P:
- Numero modello: FT440P
- Tipo: Loop Powered Flow Computer
- Ingressi: Compatible with pulse output flow sensors
- Risultati:
- Two Scaled Pulse Outputs
- One 4-20 mA Output
- Display: Digital LCD, showing instantaneous flow rate and total flow
- Isolamento: Galvanic isolation for most pulse outputs
- Dimensioni della confezione: 10.0 A x 10.0 L x 10.0 P (pollici)
- Peso del pacco: 10.0 libbre
- Paese di origine: Stati Uniti
- Produttore: Seameterics
- Primo disponibile: 3 luglio 2016
7. Informazioni sulla garanzia
Specific warranty terms and conditions for the Seametrics FT440P are provided by the manufacturer. Please refer to the documentation included with your product or visit the official Seametrics website for detailed warranty information. It is recommended to register your product upon purchase to ensure full warranty coverage.
8. Assistenza clienti
For technical assistance, troubleshooting beyond this manual, or inquiries regarding parts and service, please contact Seametrics customer support directly. Contact information can typically be found on the manufacturer's official websito o sulla confezione del prodotto.
When contacting support, please have your product model number (FT440P) and any relevant purchase details ready to facilitate a quicker resolution.