1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of your Knightsbridge IP44 180° Mini PIR Sensor, Model OS0014. This passive infrared (PIR) sensor is designed to detect motion and automatically control connected lighting or other devices, offering convenience and energy efficiency. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Informazioni sulla sicurezza

3. Prodotto finitoview

The Knightsbridge OS0014 is a compact, white, wall-mountable or ceiling-mountable PIR sensor. It features a 180° detection angle and adjustable settings for time delay and light sensitivity (LUX).

Knightsbridge IP44 Mini PIR Sensor, front-angled view

Figura 1: Angolato frontale view of the Knightsbridge IP44 Mini PIR Sensor.

Knightsbridge IP44 Mini PIR Sensor, direct front view

Figura 2: Fronte diretto view of the sensor, highlighting the detection lens.

Knightsbridge IP44 Mini PIR Sensor, side view showing wall mount

Figura 3: lato view of the sensor, illustrating its compact design and wall mounting bracket.

Knightsbridge IP44 Mini PIR Sensor, bottom view showing TIME and LUX adjustment dials

Figura 4: In basso view of the sensor, showing the 'TIME' and 'LUX' adjustment dials.

4. Installazione e configurazione

4.1 Posizione di montaggio

Choose a suitable location for mounting the sensor. It can be wall-mounted or ceiling-mounted. For optimal performance, consider the following:

4.2 Cablaggio

Avvertimento: Electrical installation should only be performed by a qualified electrician.

  1. Switch off the main power supply at the consumer unit.
  2. Carefully open the sensor housing to access the wiring terminals.
  3. Connect the live, neutral, and switched live wires according to the wiring diagram provided inside the sensor or on its packaging.
  4. Assicurarsi che tutti i collegamenti siano sicuri e correttamente isolati.
  5. Close the sensor housing securely, ensuring the IP44 rating is maintained.

5. Istruzioni per l'uso

After installation and power restoration, the sensor will enter a warm-up period (typically 30-60 seconds) during which it may cycle on and off. Once warmed up, you can adjust the settings using the dials located on the sensor (refer to Figure 4).

5.1 Regolazione del TEMPO

The 'TIME' dial controls how long the connected light or device remains on after motion is detected and then ceases. The adjustable range is approximately 10 seconds to 15 minutes. Rotate the dial clockwise to increase the duration and counter-clockwise to decrease it.

5.2 Regolazione LUX

The 'LUX' dial determines the ambient light level at which the sensor will activate. This allows the sensor to operate only when it is dark enough. The adjustable range is approximately 3 LUX (dark) to 300 LUX (daylight). Rotate the dial towards the 'sun' symbol for activation in brighter conditions or towards the 'moon' symbol for activation only in darker conditions.

Funzionamento automatico: Once configured, the sensor will automatically detect motion within its 180° field of view and 4-meter range, activating the connected load according to the set TIME and LUX levels.

6. Manutenzione

The Knightsbridge Mini PIR Sensor requires minimal maintenance. To ensure continued optimal performance:

7. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Sensor does not activate.No power; LUX setting too high; TIME setting too low; obstructed sensor.Check power supply; adjust LUX dial towards 'moon'; adjust TIME dial; clear obstructions from sensor lens.
La luce rimane costantemente accesa.Constant motion in detection area; wiring error; sensor fault.Ensure no continuous motion; verify wiring connections; if problem persists, consult a qualified electrician.
Sensor activates without apparent motion.Heat sources; small animals; strong air currents; sensor fault.Relocate sensor away from heat sources or drafts; adjust detection angle if possible; if problem persists, consult a qualified electrician.
Il raggio di rilevamento è scarso.Incorrect mounting height; obstructions; extreme temperatures.Verify mounting height; remove obstructions; ensure operating within specified temperature range.

8. Specifiche

CaratteristicaDettaglio
Numero di modelloOS0014
MarcaPonte di Knightsbridge
ColoreBianco
Fonte di alimentazioneAC
Peso dell'articolo0.1 chilogrammi (circa 3.52 once)
Portata massima di rilevamento4 metri
Angolo di rilevamento180°
Tipo di montaggioMontaggio a parete / montaggio a soffitto
Dimensioni del prodotto (P x L x A)2.76" x 3.05" x 2.13"
MaterialePolicarbonato
Caratteristiche specialiAdjustable (TIME and LUX)
Grado di protezione IPGrado di protezione IP44
Capacità di commutazioneMax. 2000W Incandescent / Max. 1000W LED
Sono necessarie batterie?NO

9. Garanzia e supporto