1. Introduzione
This manual provides detailed instructions for the installation, operation, and maintenance of your Knightsbridge IP44 180° Mini PIR Sensor, Model OS0014. This passive infrared (PIR) sensor is designed to detect motion and automatically control connected lighting or other devices, offering convenience and energy efficiency. Please read this manual thoroughly before installation and use to ensure proper function and safety.
2. Informazioni sulla sicurezza
- L'installazione deve essere effettuata da un elettricista qualificato, nel rispetto delle normative nazionali in materia di cablaggio.
- Prima di iniziare qualsiasi lavoro di installazione o manutenzione, assicurarsi che l'alimentazione principale sia disattivata.
- This product is rated IP44, making it suitable for outdoor use where protection against splashing water is required.
- Do not exceed the maximum load ratings specified for this device.
- Keep the sensor lens clean and free from obstructions to ensure optimal performance.
3. Prodotto finitoview
The Knightsbridge OS0014 is a compact, white, wall-mountable or ceiling-mountable PIR sensor. It features a 180° detection angle and adjustable settings for time delay and light sensitivity (LUX).

Figura 1: Angolato frontale view of the Knightsbridge IP44 Mini PIR Sensor.

Figura 2: Fronte diretto view of the sensor, highlighting the detection lens.

Figura 3: lato view of the sensor, illustrating its compact design and wall mounting bracket.

Figura 4: In basso view of the sensor, showing the 'TIME' and 'LUX' adjustment dials.
4. Installazione e configurazione
4.1 Posizione di montaggio
Choose a suitable location for mounting the sensor. It can be wall-mounted or ceiling-mounted. For optimal performance, consider the following:
- Avoid mounting near heat sources (e.g., air conditioning vents, heaters) that could cause false triggers.
- Assicurarsi che l'area di rilevamento sia libera da grandi ostacoli.
- Mount at a height that allows for effective detection within the 4-meter range and 180° angle.
4.2 Cablaggio
Avvertimento: Electrical installation should only be performed by a qualified electrician.
- Switch off the main power supply at the consumer unit.
- Carefully open the sensor housing to access the wiring terminals.
- Connect the live, neutral, and switched live wires according to the wiring diagram provided inside the sensor or on its packaging.
- Assicurarsi che tutti i collegamenti siano sicuri e correttamente isolati.
- Close the sensor housing securely, ensuring the IP44 rating is maintained.
5. Istruzioni per l'uso
After installation and power restoration, the sensor will enter a warm-up period (typically 30-60 seconds) during which it may cycle on and off. Once warmed up, you can adjust the settings using the dials located on the sensor (refer to Figure 4).
5.1 Regolazione del TEMPO
The 'TIME' dial controls how long the connected light or device remains on after motion is detected and then ceases. The adjustable range is approximately 10 seconds to 15 minutes. Rotate the dial clockwise to increase the duration and counter-clockwise to decrease it.
5.2 Regolazione LUX
The 'LUX' dial determines the ambient light level at which the sensor will activate. This allows the sensor to operate only when it is dark enough. The adjustable range is approximately 3 LUX (dark) to 300 LUX (daylight). Rotate the dial towards the 'sun' symbol for activation in brighter conditions or towards the 'moon' symbol for activation only in darker conditions.
Funzionamento automatico: Once configured, the sensor will automatically detect motion within its 180° field of view and 4-meter range, activating the connected load according to the set TIME and LUX levels.
6. Manutenzione
The Knightsbridge Mini PIR Sensor requires minimal maintenance. To ensure continued optimal performance:
- Pulire periodicamente la lente del sensore con un panno morbido eamp cloth to remove dust, dirt, or debris that may obstruct detection. Do not use abrasive cleaners.
- Ensure the sensor is free from physical damage.
7. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Sensor does not activate. | No power; LUX setting too high; TIME setting too low; obstructed sensor. | Check power supply; adjust LUX dial towards 'moon'; adjust TIME dial; clear obstructions from sensor lens. |
| La luce rimane costantemente accesa. | Constant motion in detection area; wiring error; sensor fault. | Ensure no continuous motion; verify wiring connections; if problem persists, consult a qualified electrician. |
| Sensor activates without apparent motion. | Heat sources; small animals; strong air currents; sensor fault. | Relocate sensor away from heat sources or drafts; adjust detection angle if possible; if problem persists, consult a qualified electrician. |
| Il raggio di rilevamento è scarso. | Incorrect mounting height; obstructions; extreme temperatures. | Verify mounting height; remove obstructions; ensure operating within specified temperature range. |
8. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Numero di modello | OS0014 |
| Marca | Ponte di Knightsbridge |
| Colore | Bianco |
| Fonte di alimentazione | AC |
| Peso dell'articolo | 0.1 chilogrammi (circa 3.52 once) |
| Portata massima di rilevamento | 4 metri |
| Angolo di rilevamento | 180° |
| Tipo di montaggio | Montaggio a parete / montaggio a soffitto |
| Dimensioni del prodotto (P x L x A) | 2.76" x 3.05" x 2.13" |
| Materiale | Policarbonato |
| Caratteristiche speciali | Adjustable (TIME and LUX) |
| Grado di protezione IP | Grado di protezione IP44 |
| Capacità di commutazione | Max. 2000W Incandescent / Max. 1000W LED |
| Sono necessarie batterie? | NO |
9. Garanzia e supporto
For warranty information or technical support, please refer to the documentation provided with your purchase or contact Knightsbridge customer service directly. Keep your proof of purchase for any warranty claims.