Introduzione
This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Informazioni sulla sicurezza
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Questo prodotto è progettato esclusivamente per uso interno.
- Non collegare più prese multiple tra loro.
- Assicurarsi che la ciabatta sia correttamente messa a terra.
- Non aprire o modificare il dispositivo. Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato.
- Tenere lontano dall'acqua e da ambienti ad alta umidità.
- Ensure proper ventilation when installed in a rack.
Contenuto della confezione
Verificare che tutti gli articoli siano presenti e integri:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Manuale d'uso
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Prodotto finitoview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Immagine: Un completo view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Caratteristiche principali:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Immagine: Un dettaglio view of the angled Schuko power plug, which connects the power strip to the main power source.
Configurazione e installazione
- Disimballare la ciabatta: Estrarre con cautela la ciabatta dalla confezione. Verificare che non presenti segni di danneggiamento.
- Scegli la posizione di montaggio: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Connetti alla fonte di alimentazione: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Connetti dispositivi: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Immagine: Una parziale view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Operazione
- Accensione: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Protezione da sovraccarico: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Spegni: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Manutenzione
- Pulizia: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Ispezione: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Ventilazione: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| No power to outlets. | L'interruttore di circuito è scattato. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| No power to outlets. | Ciabatta non collegata. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti.
Specifiche
- Modello: I-CASE STRIP-12SH
- Marca: Techly Professional
- Punti vendita: 12 x Schuko (Type F) 45° angled with earth
- Spina di ingresso: Angled Schuko (Type F)
- Cavo: H05VV-F 3G 2.5 mm²
- Lunghezza del cavo: 3 metri
- Valutazione elettrica: 16 A, 250 V CA
- Capacità di carico massima: 3.5 kW
- Dimensioni (L x P x A): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Peso: 1795 grammi
- Materiale: Aluminum (body), Black (finish)
- Caratteristica speciale: Mountable (vertical rack installation)
- Certificazioni: CE, RAEE
Informazioni sulla garanzia
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Politica di ritorno: Il vincitore della Buybox indica una politica di reso di 30 giorni (rimborso/sostituzione).
Assistenza clienti
For technical assistance or further inquiries, please visit the official Techly websito o contattare il rivenditore.
Produttore: TECHLY PROFESSIONAL
Websito: www.techly.com (Hypothetical link, as not provided in JSON)