Modello XPOWER FM-48

XPOWER Misting Fan FM-48

Manuale di istruzioni

Modello: FM-48

Introduzione

Thank you for choosing the XPOWER FM-48 Misting Fan. This heavy-duty, high-velocity fan is designed to provide effective outdoor cooling by lowering ambient temperatures, while also helping to keep dust, pollen, and flying insects at bay. It can also be used indoors as a powerful air circulator without the misting feature. Please read this manual thoroughly before operation to ensure safe and efficient use.

Impostare

The XPOWER FM-48 Misting Fan is designed for quick and easy setup. Follow these steps to get your fan ready for use:

  1. Posizionamento: Position the fan on a stable, level surface in the desired outdoor area. Ensure it is away from direct sunlight and any obstructions that might block airflow or mist distribution.
  2. Collegamento idrico: Connect a standard garden hose to the fan's water inlet. Ensure the connection is secure to prevent leaks. The fan requires only a garden hose for its misting function.
  3. Collegamento elettrico: Plug the fan's three-pronged AC power plug into a grounded electrical outlet. The unit is ETL/CETL safety certified.
  4. Controllo iniziale: Before turning on, ensure all connections are tight and the fan is positioned safely.
XPOWER FM-48 Misting Fan connected to a garden hose

Image: The XPOWER FM-48 Misting Fan with a garden hose connected, illustrating the water input setup.

Video: Official XPOWER video demonstrating the setup and features of the FM-48 Misting Fan. This video provides a visual guide to connecting the unit and its initial operation.

Istruzioni per l'uso

The FM-48 Misting Fan offers versatile operation for various cooling and air circulation needs:

  • Accensione/spegnimento e controllo della velocità: Use the 3-speed control switch located on the unit to turn the fan on and select your desired airflow speed (Low, Medium, High).
  • Funzione di nebulizzazione: To activate misting, ensure the water hose is connected and the water supply is turned on. The fan will begin to produce a fine mist. The misting intensity is dependent on the water pressure and fan speed.
  • Directional Cooling: The fan features a 135-degree rotational stand, allowing you to adjust the angle of the airflow and mist for precise directional cooling.
  • Non-Misting Use: The FM-48 can be used as a powerful air circulator without the misting feature. Simply do not connect a water hose or turn off the water supply while the fan is running.
XPOWER FM-48 Misting Fan control panel with speed dial and mist nozzles

Image: Close-up of the FM-48's control panel, showing the 3-speed dial and the mist nozzles, highlighting key operational features.

XPOWER FM-48 Misting Fan demonstrating 135-degree directional cooling

Image: An illustration showing the 135-degree rotational capability of the FM-48, allowing for flexible directional cooling.

Manutenzione

Regular maintenance ensures optimal performance and longevity of your XPOWER FM-48 Misting Fan:

  • Pulizia degli ugelli: To prevent mineral buildup and clogging, it is recommended to remove the mist nozzles after each use and soak them in a descaling solution (e.g., CLR) or a vinegar-water mixture. Rinse thoroughly before reattaching.
  • Pulizia generale: Pulisci l'esterno della ventola con l'annuncioamp cloth. The sealed motor design protects internal components from water and debris, but external cleanliness is still important.
  • Magazzinaggio: When not in use, especially during off-season, ensure the fan is clean and dry. The durable housing features a convenient wrap-around design to keep the power cord and water hose neat for easy storage.
XPOWER FM-48 Misting Fan showing compact design for storage

Image: The FM-48 Misting Fan showcasing its compact and durable design, ideal for easy storage when not in use.

Risoluzione dei problemi

If you encounter issues with your FM-48 Misting Fan, refer to the following common problems and solutions:

ProblemaPossibile causaSoluzione
La ventola non si accende.Nessuna corrente, presa difettosa, cavo danneggiato.Check power connection, try a different outlet, inspect power cord for damage. If damaged, contact customer service.
Nessuna nebbia o nebbia debole.Water supply off, low water pressure, clogged nozzles.Ensure water hose is connected and water supply is on. Check water pressure. Clean mist nozzles as per maintenance instructions.
Perdita d'acqua dai collegamenti.Loose hose connection, damaged O-ring/seal.Tighten all hose connections. Inspect O-rings and seals for wear or damage and replace if necessary.
La ventola è rumorosa.Obstruction in fan blades, unit not on a stable surface.Turn off and unplug the fan. Check for any debris obstructing the fan blades. Ensure the unit is placed on a flat, stable surface.

Specifiche

CaratteristicaDettaglio
MarcaPotere X
ModelloFM-48
Dimensioni del prodotto12.3"P x 13.3"L x 15.2"A
Peso dell'articolo12 libbre
Fonte di alimentazioneElettrico con cavo
Voltage110 Volt
Cosatage144 watt
Capacità del flusso d'aria600 piedi cubi
Numero di velocità3
Caratteristiche specialiAdjustable Speed, Portable, Rotatable, Lightweight, Durable, Oscillating, Built-In Pump, Water Resistant
Certificazione di sicurezzaCertificato ETL / CETL

Garanzia e supporto

The XPOWER FM-48 Misting Fan comes with a Garanzia limitata di 1 anno. For any product inquiries, technical assistance, or warranty claims, please contact XPOWER's California-based customer service team. They are dedicated to providing comprehensive support and ensuring a first-class customer experience.

For detailed warranty information and additional support resources, please refer to the official XPOWER websito o il manuale utente completo fornito con il prodotto.

Manuale utente ufficiale (PDF): Scarica qui

Documenti correlati - FM-48

Preview Ventilatore nebulizzatore XPOWER FM-48: Manuale di funzionamento, sicurezza e manutenzione
Manuale d'uso ufficiale per il ventilatore nebulizzatore XPOWER FM-48. Fornisce istruzioni dettagliate su funzionamento, precauzioni di sicurezza, procedure di manutenzione, risoluzione dei problemi, elenco dei componenti e specifiche del prodotto. Include informazioni sulla garanzia e altri prodotti XPOWER.
Preview Manuale utente del ventilatore nebulizzatore XPOWER FM-48
Manuale utente completo per il ventilatore nebulizzatore XPOWER FM-48, che illustra funzionamento, istruzioni di sicurezza, manutenzione, risoluzione dei problemi e specifiche del prodotto. Scopri come utilizzare e manutenere il tuo ventilatore nebulizzatore XPOWER per ottenere prestazioni ottimali.
Preview Manuale d'uso del ventilatore nebulizzatore/circolatore d'aria ricaricabile XPOWER
Manuale completo del proprietario per i ventilatori a circolazione d'aria e nebulizzatori ricaricabili XPOWER (modelli FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB), che comprende istruzioni di sicurezza, articoli inclusi, presentazione del prodotto, descrizione dei componenti, installazione, funzionamento, collegamento alla fonte d'acqua, ricarica, manutenzione, risoluzione dei problemi e specifiche tecniche.
Preview Manuale d'uso del ventilatore nebulizzatore/circolatore d'aria ricaricabile XPOWER
Questo manuale fornisce istruzioni complete per il funzionamento, la manutenzione e la risoluzione dei problemi dei circolatori d'aria ricaricabili e dei ventilatori nebulizzatori XPOWER. ...
Preview Manuale d'uso del ventilatore nebulizzatore/circolatore d'aria ricaricabile XPOWER | FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB
Manuale d'uso completo per i ventilatori a circolazione d'aria e nebulizzatori ricaricabili XPOWER (modelli FC-125B, FC-150B, FM-65B, FM-65WB, FT-65WB). Include istruzioni di sicurezza, guide operative, suggerimenti per la manutenzione, risoluzione dei problemi e specifiche tecniche.
Preview Manuale utente del ventilatore nebulizzatore XPOWER: FM-68, FM-68W, FM-88W, FT-68W, FT-88W
Manuale utente completo per i ventilatori nebulizzatori XPOWER, modelli FM-68, FM-68W, FM-88W, FT-68W, FT-88W. Include istruzioni di sicurezza, funzionamento, manutenzione e specifiche tecniche.