Paradox 307-USB-modul

Manuale utente del modulo Paradox 307-USB

Your comprehensive guide to the Paradox 307-USB Module for direct PC-to-panel connection.

1. Introduzione

The Paradox 307-USB Module is an essential interface designed for direct communication between your personal computer (PC) and Paradox security control panels. This module simplifies the process of programming, configuring, and managing your security system by providing a reliable USB connection.

It features a USB port and a serial port (DB-9), along with three LED indicators for PC, Central, and RX/TX status, offering clear visual feedback on the communication link.

Paradox 307-USB Module, a white rectangular device with a USB port, a DB-9 serial port, and a cable with a white connector.

Figure 1: The Paradox 307-USB Module, showing its compact design, USB and serial (DB-9) ports, and the integrated connection cable. This module facilitates direct data exchange between a computer and a Paradox security system panel.

2. Configurazione e installazione

Follow these steps to set up your Paradox 307-USB Module for the first time:

  1. Connetti al PC: Plug the USB end of the 307-USB Module into an available USB port on your computer. The module is generally plug-and-play and often does not require specific driver installation, especially on modern operating systems like Windows 10.
  2. Connect to Control Panel: Connect the serial (DB-9) port of the 307-USB Module to the corresponding serial communication port on your Paradox security control panel. Ensure a secure connection.
  3. Installazione del software: Download and install the necessary Paradox programming software (e.g., WinLoad, BabyWare) from the official Paradox website. This software is crucial for configuring and managing your security system through the module.
  4. Verifica connessione: Once connected, observe the three LED indicators on the module:
    • PC LED: Indicates connection and communication with the PC.
    • Led centrale: Indicates connection and communication with the control panel.
    • LED RX/TX: Flashes during data transmission (Receive/Transmit) between the PC and the control panel.
  5. Comunicazione iniziale: Open the Paradox programming software on your PC. Configure the software to use the correct communication port (usually a virtual COM port assigned to the USB module). Attempt to establish communication with the control panel.

The module supports communication speeds of up to 38.4 K with Digiplex EVO central units and 9.6 K with Magellan and Spectra SP central units.

3. Istruzioni per l'uso

The Paradox 307-USB Module acts as a bridge, facilitating data exchange. Its operation is primarily managed through the Paradox programming software on your PC.

4. Manutenzione

The Paradox 307-USB Module is designed for low maintenance. To ensure its longevity and reliable performance, consider the following:

5. Risoluzione Dei Problemi

If you encounter issues with your Paradox 307-USB Module, refer to the following common troubleshooting steps:

ProblemaPossibile causaSoluzione
PC LED is offModule not connected to PC, or PC USB port issue.Ensure the USB cable is securely plugged into the PC. Try a different USB port. Restart the PC.
Central LED is offModule not connected to control panel, or control panel is off.Verify the DB-9 serial connection to the control panel. Ensure the control panel is powered on.
RX/TX LEDs not flashing during communication attemptNo data transfer, incorrect software settings, or communication error.
  • Check the communication port settings in your Paradox software (e.g., COM port number).
  • Ensure the correct control panel model is selected in the software.
  • Verify the control panel's communication settings.
  • Restart the Paradox software and try again.
Software cannot detect module/panelDriver issue (rare), incorrect COM port, or software conflict.
  • Check Device Manager on your PC to confirm the module is recognized and assigned a COM port.
  • Ensure no other software is using the same COM port.
  • Reinstall the Paradox programming software.

If problems persist, consult the Paradox programming software's help documentation or contact Paradox technical support.

6. Specifiche

Key technical specifications for the Paradox 307-USB Module:

7. Informazioni sulla garanzia

Specific warranty terms for the Paradox 307-USB Module are provided by the manufacturer, Paradox, and may vary based on region and point of purchase. Please retain your proof of purchase for warranty claims.

For detailed warranty information, including coverage period and conditions, please refer to the documentation included with your product or visit the official Paradox website. Any repairs or modifications performed by unauthorized personnel will void the warranty.

8. Supporto tecnico e contatti

For technical assistance, troubleshooting beyond this manual, or inquiries regarding your Paradox 307-USB Module, please contact Paradox technical support.

When contacting support, please have your product model (307-USB Module) and any relevant error messages or observations ready to facilitate a quicker resolution.

Documenti correlati - 307-USB-modul

Preview Visualizza il Paradox Magellan & Spectra SP
Ολοκληρωμένος οδηγός προγραμματισμού για τις σειρές συστημάτων Per Paradox Magellan in Spectra SP, per il download, per l'acquisto προηγμένες λειτουργίες.
Preview Guida all'installazione e alla programmazione del modulo di espansione Paradox PGM4 V3.0
Guida completa per l'installazione e la programmazione del modulo di espansione Paradox PGM4 a 4 uscite (V3.0) con centrali compatibili come Digiplex, EVO, MG/SP, Esprit E55 e Spectra. ...
Preview Manuale di installazione del modulo ripetitore wireless Paradox RPT1+
Manuale di installazione per il modulo ripetitore wireless Paradox RPT1+, che descrive in dettaglio le sue caratteristiche, i passaggi di installazione e le informazioni di programmazione per potenziare i sistemi di allarme Magellan e Spectra SP.
Preview Paradox Magellan & Spectra Series: Manuale di riferimento e installazione
Guida completa di riferimento e installazione per le centrali di allarme Paradox serie Magellan e Spectra, che illustra caratteristiche, specifiche, programmazione e risoluzione dei problemi per gli installatori.
Preview Guida alla programmazione Digiplex EVO192: sistema di sicurezza e accesso elevati
Guida completa alla programmazione del sistema di accesso e sicurezza Paradox Digiplex EVO192 (V7.11), che descrive in dettaglio la configurazione, la programmazione delle zone e le impostazioni del sistema.
Preview Manuale utente del sistema di allarme Paradox Magellan e Spectra SP
Manuale utente completo per i sistemi di allarme Paradox Magellan (MG5000, MG5050) e Spectra SP (SP65, SP4000, SP5500, SP6000, SP7000), che illustra funzionamento, caratteristiche e programmazione.