1. Introduzione
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Gree 18,000 BTU Multi21+ Dual-Zone Wall Mount Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before installation and operation, and retain it for future reference. This system is designed to provide both cooling and heating for two separate zones, utilizing Gree's G10 inverter-driven compressor technology for energy efficiency and consistent comfort.

Figura 1.1: Sopraview of the Gree Multi21+ Dual-Zone Mini Split System. This image displays the complete system, including two indoor wall-mounted units, two remote controls for individual zone management, and a single outdoor condenser unit, illustrating the multi-zone capability.
2. Informazioni sulla sicurezza
Always adhere to the following safety precautions to prevent injury, damage to property, or damage to the unit. Improper operation due to ignoring instructions may cause harm or damage.
2.1 Avvertenze generali di sicurezza
- Installazione professionale richiesta: Installation, maintenance, and repair of this unit must be performed by qualified and certified HVAC professionals. Incorrect installation can lead to electric shock, fire, or water leakage.
- Sicurezza elettrica: Ensure the power supply matches the unit's specifications (208/230V). Do not operate with wet hands. Always disconnect power before servicing.
- Gestione del refrigerante: This unit uses R410A refrigerant. Handling of refrigerant must be done by certified personnel only.
- Ventilazione: Assicurare una ventilazione adeguata durante l'installazione e la manutenzione.
- Bambini e animali domestici: Tenere bambini e animali domestici lontani dall'unità durante il funzionamento e la manutenzione.
- Materiali infiammabili: Do not place flammable materials or spray aerosols near the unit.
2.2 Requisiti elettrici
The unit requires a 208/230V power supply. All electrical wiring must comply with local and national electrical codes. A dedicated circuit breaker is recommended for the unit.
3. Configurazione e installazione
Proper installation is critical for the performance and longevity of your Gree Mini Split system. It is strongly recommended that installation be performed by a licensed HVAC technician.
3.1 Controlli pre-installazione
- Verificare che tutti i componenti siano presenti e integri.
- Ensure the installation location for both indoor and outdoor units meets clearance requirements and structural integrity.
- Confirm the availability of the required 1/4" x 3/8" line sets (two sets are needed for this dual-zone system), which are not included with the unit.
3.2 Installazione finitaview
- Mounting the Indoor Units: Select appropriate wall locations for each indoor unit, ensuring proper drainage and air circulation.
- Montaggio dell'unità esterna: Choose a stable, level outdoor location with sufficient airflow and clearance from obstructions.
- Collegamento delle linee del refrigerante: Connect the pre-flared refrigerant lines between the indoor and outdoor units. Proper vacuuming of the lines is essential.
- Collegamenti elettrici: Connect the power supply and communication wiring according to the wiring diagram provided in the full installation manual.
- Drenaggio: Installare le linee di scarico della condensa per ogni unità interna, assicurandosi che la pendenza sia adeguata per il drenaggio per gravità.
- Leak Checks and Test Run: After all connections are made, perform a leak check and a test run to ensure proper operation.

Figura 3.1: Dettagliato view of an indoor wall-mounted unit. This image highlights the sleek design and digital display of the indoor unit, which should be mounted securely on an interior wall.

Figura 3.2: Example of an indoor unit installed in a living room setting. This image demonstrates how the compact design of the indoor unit integrates seamlessly into a modern living space.
4. Istruzioni per l'uso
Your Gree Multi21+ system offers various modes to ensure year-round comfort. Each indoor unit can be controlled independently for dual-zone climate control.
4.1 Modalità operative di base
- Modalità fredda: For cooling the room. Set desired temperature using the remote control.
- Modalità di calore: For heating the room. The heat pump efficiently provides warmth.
- Modalità ventola: Fa circolare l'aria senza riscaldare o raffreddare. La velocità della ventola è regolabile.
- Modalità di asciugatura (deumidificazione): Riduce l'umidità nella stanza.
- Modalità automatica: Seleziona automaticamente il raffreddamento o il riscaldamento in base alla temperatura impostata e alla temperatura ambiente attuale.
4.2 Utilizzo del telecomando
Each indoor unit comes with its own remote control. Point the remote directly at the indoor unit when operating. Common functions include:
- Pulsante ON/OFF: Accende o spegne l'unità.
- Pulsante MODE: Passa attraverso le modalità operative (Raffreddamento, Riscaldamento, Ventilatore, Deumidificazione, Auto).
- Pulsanti di regolazione della temperatura: Aumenta o diminuisce la temperatura impostata.
- Pulsante velocità ventola: Regola la velocità della ventola (Auto, Bassa, Media, Alta).
- Pulsante oscillante: Controlla la direzione delle alette per una distribuzione ottimale dell'aria.
- Funzione timer: Imposta l'unità in modo che si accenda o si spenga automaticamente a un orario specificato.

Figura 4.1: Visual representation of the cooling and heating capabilities. This image illustrates the system's ability to provide both cool air during warmer periods and warm air during colder periods, ensuring year-round comfort.
4.3 Controllo Wi-Fi (facoltativo)
The Gree Multi21+ system offers an option to upgrade with a field-installed Wi-Fi kit accessory (sold separately). This allows you to remotely control the unit using your smartphone via a dedicated application. Consult the Wi-Fi kit's instructions for pairing and setup.

Figura 4.2: Users interacting with their smartphones, suggesting remote control capabilities. This image implies the convenience of controlling the air conditioning system from a mobile device, a feature available with the optional Wi-Fi kit.
5. Manutenzione
Regular maintenance ensures optimal performance, energy efficiency, and extends the lifespan of your unit. Always disconnect power before performing any maintenance.
5.1 Pulizia del filtro dell'aria
- Frequenza: Clean air filters every two weeks or more frequently depending on usage and air quality.
- Procedura:
- Aprire il pannello frontale dell'unità interna.
- Rimuovere i filtri dell'aria.
- Pulire i filtri con un aspirapolvere o lavarli con acqua tiepida e un detergente delicato.
- Lasciare asciugare completamente i filtri prima di reinserirli.
5.2 Manutenzione dell'unità esterna
- Frequenza: Inspect and clean the outdoor unit coils and fins annually, or more often if located in a dusty environment.
- Procedura:
- Assicurarsi che l'unità esterna sia spenta.
- Remove any debris (leaves, dirt, etc.) from around the unit.
- Gently clean the coil fins with a soft brush or water hose. Avoid bending the fins.
- Ensure the drainage holes at the base of the unit are clear.
5.3 Assistenza professionale
It is recommended to have a qualified HVAC technician perform a comprehensive service check on your system annually. This includes checking refrigerant levels, electrical connections, and overall system performance.
6. Risoluzione Dei Problemi
Prima di contattare l'assistenza clienti, fai riferimento ai seguenti problemi comuni e alle loro possibili soluzioni.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'unità non si accende. | Nessuna alimentazione; interruttore automatico scattato; batterie del telecomando scariche. | Controllare il collegamento elettrico; ripristinare l'interruttore automatico; sostituire le batterie del telecomando. |
| Raffreddamento/riscaldamento insufficiente. | Dirty air filters; blocked outdoor unit; low refrigerant; wrong mode selected. | Clean air filters; clear obstructions from outdoor unit; contact technician for refrigerant check; select correct operating mode. |
| Perdita d'acqua dall'unità interna. | Tubo di scarico intasato; installazione non corretta. | Clear drain pipe; contact technician for inspection. |
| Rumore insolito. | Loose parts; foreign objects in fan; compressor issue. | Check for loose parts; remove foreign objects; contact technician if noise persists. |
If the problem persists after attempting these solutions, please contact a qualified HVAC technician or Gree customer support.
7. Specifiche
Key technical specifications for the Gree 18,000 BTU Multi21+ Dual-Zone Mini Split Air Conditioner Heat Pump.
| Caratteristica | Dettaglio |
|---|---|
| Numero di modello | MULTI18CLIV200 |
| Capacità | 18,000 BTU (1.5 tonnellate) |
| Zone | Dual-Zone (9K, 9K) |
| SEER (rapporto di efficienza energetica stagionale) | 22.00 |
| EER (Indice di efficienza energetica) | 12.50 |
| Voltage | 208/230 Volt |
| Tipo di refrigerante | R410A |
| Livello di rumore (unità esterna) | 56 dB |
| Copertura stimata delle dimensioni della stanza | 600 - 1,000 sq ft |
| Caratteristiche speciali | Air Purification Filter, G10 Inverter Technology, Optional Wi-Fi Control |
| Materiale | Acciaio |
| Colore | Bianco |
| Peso dell'articolo | 40 libbre |
| Dimensioni del prodotto | 10 x 29 x 11 inches (Indoor Unit, typical) |
8. Garanzia e supporto
Gree products are manufactured to high standards and come with a manufacturer's warranty. Specific warranty terms and conditions may vary. Please refer to the warranty card included with your product or visit the official Gree websito per informazioni dettagliate.
8.1 Assistenza clienti
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Gree customer support or your authorized Gree dealer. Ensure you have your model number (MULTI18CLIV200) and purchase date available when contacting support.
Puoi trovare maggiori informazioni e risorse di supporto sul sito ufficiale GREE Store on Amazon.