Introduzione
This manual provides detailed instructions for the installation, operation, and maintenance of the Trane KIT18110 OEM Upgraded Furnace Control Board Kit. This kit is designed as an American Standard / Trane OEM component for furnace units built after 1995. It includes the control board (CNT07541), ignitor, wire harness, and bracket.
Nota importante: For downflow units built in 1999 and earlier, use KIT18109. For all other units built after 1995, use KIT18110.
Informazioni sulla sicurezza
AVVERTIMENTO: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment.
- Always disconnect all power to the furnace before installing or servicing the control board. Failure to do so can result in electrical shock, personal injury, or death.
- Assicurare la corretta messa a terra della fornace e di tutti i componenti elettrici.
- Indossare adeguati dispositivi di protezione individuale (DPI), tra cui occhiali e guanti di sicurezza.
- Verify all wiring connections are secure and correct according to the furnace manufacturer's specifications and local electrical codes.
- Non bypassare alcun dispositivo di sicurezza.
Contenuto della confezione
The Trane KIT18110 kit typically includes the following components:
- Integrated Furnace Control Board (CNT07541)
- Ignitor
- Cablaggio
- Staffa di fissaggio
- Istruzioni per l'installazione

Image: The Trane KIT18110 furnace control board kit, showing the main circuit board, ignitor, and mounting hardware.
Compatibilità
This kit is an OEM replacement for various American Standard and Trane units built after 1995. It supersedes several older control board models. Always verify compatibility with your specific furnace model before installation.
Replaces / Supersedes Part Numbers:
- CNT-2854 / CNT02854
- CNT-3076 / CNT03076
- CNT-3798 / CNT03798
- CNT-5164 / CNT05164
- CNT-5165 / CNT05165
- CNT-5995 / CNT05995
- BAF00359 / BAF0359 / BAF-0359
- CNT05885 / CNT-5885
- CNT03604 / CNT-3604
- CNT07541 / CNT7541 / CNT-7541
- 50A65-475 / 50A65-475-07
- D341396P05 / D341396P03 / D341213P01 / D341396P01
- 50A65-120 / 50A65-143 / 50A65-288
- And many others.
Commonly Found in Models:
This kit is commonly found in the following A/TDX and A/TUX Gas Furnace Models:
- AUH1B040A9241AA, AUH1B040A9241AB
- AUH1B060A9361AA, AUH1B060A9361AB
- AUH1B080A9421AA, AUH1B080A9421BA, AUH1B080A9421BB
- AUH1C080A9601AA, AUH1C100A9481AA
- AUH1D100A9601AA, AUH1D120A9601AA
- TUH1B040A9241AA, TUH1B040A9241AB
- TUH1B060A9361AA, TUH1B060A9361AB
- TUH1B080A9421AA, TUH1B080A9421BA, TUH1B080A9421BB
- TUH1C080A9601AA, TUH1C100A9481AA
- TUH1D100A9601AA, TUH1D120A9601AA

Image: A stamp indicating "Trane OEM Component," signifying genuine parts.
Installazione / Configurazione
This procedure is intended for qualified technicians. Refer to your furnace's specific service manual for detailed wiring diagrams and safety precautions.
- Disconnessione dell'alimentazione: Locate the main power switch for your furnace and turn it OFF. Additionally, turn off power at the circuit breaker or fuse box. Verify power is off using a voltage metro.
- Scheda di controllo degli accessi: Aprire il pannello di accesso alla fornace per esporre la scheda di controllo esistente.
- Cablaggio del documento: Before disconnecting any wires, take clear photographs of all existing wiring connections to the old control board. Label wires if necessary to ensure correct re-connection.
- Scollegare i fili: Scollegare con attenzione tutti i cavi dalla vecchia scheda di controllo.
- Rimuovere la vecchia scheda: Unscrew or unclip the old control board from its mounting location.
- Installa la nuova scheda: Mount the new Trane KIT18110 control board using the provided bracket and screws. Ensure it is securely fastened.
- Collegare il cablaggio: Refer to your photographs and the wiring diagram in your furnace manual to connect all wires to the new control board. Pay close attention to terminal markings (e.g., R, W, Y, G, C).
- Install Ignitor: Replace the old ignitor with the new one provided in the kit, ensuring proper seating and connection to the control board via the wire harness.
- Pannelli protetti: Chiudere e fissare tutti i pannelli di accesso alla caldaia.
- Ripristina alimentazione: Restore power to the furnace at the circuit breaker or fuse box, then turn on the main power switch for the furnace.
- Operazione di prova: Initiate a heating cycle to verify proper furnace operation, including ignition, fan operation, and temperature control. Observe for any error codes or unusual behavior.
Operazione
The Trane KIT18110 control board is an integrated furnace control that manages the sequence of operation for your furnace. Once correctly installed, it will automatically control the ignition, fan, and safety functions based on signals from the thermostat and internal sensors. No direct user interaction with the control board is required for normal operation.
Refer to your furnace's user manual for instructions on setting your thermostat and general furnace operation.
Manutenzione
The control board itself typically requires no routine maintenance. However, regular maintenance of your furnace system is crucial for its longevity and efficient operation. This includes:
- Sostituzione del filtro: Replace or clean your furnace air filter regularly (monthly or as recommended by your furnace manufacturer).
- Ispezioni annuali: Schedule annual professional inspections and tune-ups for your furnace.
- Prese d'aria trasparenti: Assicurarsi che tutte le prese d'aria di mandata e di ritorno siano libere da ostruzioni.
- Clean Burners: Keep burner areas clean and free of debris.
Always disconnect power before performing any maintenance on the furnace.
Risoluzione dei problemi
The control board features diagnostic LED indicators that can help identify system faults. Consult your furnace's service manual for a detailed list of error codes and their meanings. Common issues and initial checks include:
- No Heat / No Power:
- Check if the furnace power switch is ON.
- Verify the circuit breaker for the furnace has not tripped.
- Ensure the thermostat is set to "Heat" and the temperature is above the ambient room temperature.
- Check for a blown fuse on the control board (if applicable).
- Furnace Not Igniting:
- Check the ignitor for cracks or damage.
- Assicurarsi che la valvola di alimentazione del gas sia aperta.
- Verify the flame sensor is clean and properly positioned.
- La ventola non funziona:
- Check if the thermostat fan setting is on "Auto" or "On".
- Ensure the air filter is not excessively dirty, restricting airflow.
- Codici di errore: Observe the diagnostic LED on the control board. Count the flashes or refer to the specific pattern to identify the fault code. Consult your furnace manual for the corresponding issue and recommended solution.
If you are unable to resolve an issue, contact a qualified HVAC technician.
Specifiche
| Numero modello articolo | KIT18110 |
| Produttore | Trane |
| Compatibilità | American Standard / Trane units built after 1995 |
| Il kit include | Control Board (CNT07541), Ignitor, Wire Harness, Bracket |
| Dimensioni del pacco | 12.09 x 7.2 x 5.08 pollici |
| Peso dell'articolo | 15.17 once |
Informazioni sulla garanzia
Specific warranty details for the Trane KIT18110 control board kit are typically provided by the point of purchase or Trane directly. It is recommended to retain your purchase receipt and consult the official Trane warranty documentation for your specific product. Generally, OEM parts carry a limited warranty against manufacturing defects.
Supporto