The MSA ALTAIR 4XR Multigas Detector is a robust, handheld, portable gas monitor designed for critical safety applications. It is capable of simultaneously detecting up to four gases: Lower Explosive Limit (LEL), Oxygen (O2), Hydrogen Sulfide (H2S), and Carbon Monoxide (CO). Engineered for durability, this device features a tough over-molded rubber armor, is MIL-STD-810G drop protected, and boasts an IP68 rating for dust and water resistance, ensuring reliable performance in demanding environments.

MSA ALTAIR 4XR Multigas Detector front view

Figura 1: Fronte view of the MSA ALTAIR 4XR Multigas Detector, showing the display and control buttons.

Caratteristiche principali

Impostazione e calibrazione

Before initial use or after prolonged storage, it is essential to perform a fresh air setup (zero calibration) and a span calibration to ensure accurate readings. Always perform these procedures in a clean, fresh air environment free from contaminants.

Attrezzatura richiesta:

Zero Calibration (Fresh Air Setup):

  1. Power on the ALTAIR 4XR detector by pressing and holding the middle button. Allow it to complete its startup sequence and warm-up procedure.
  2. When prompted for a "Fresh Air Setup" (FAS), select "No" to proceed to normal operating mode. This ensures a high-quality zero calibration.
  3. Once in normal operating mode, press and hold the right button until the display shows "ZERO CAL?".
  4. Press the middle button to confirm "Zero Cal". The unit will enter "SENSOR REFRESH" mode. Ensure the detector is in a clean air environment, free from any gas sources or residual gas.
  5. Allow the unit to complete the zero calibration. The display will indicate when it's complete.

Calibrazione Span:

  1. Ensure the calibration gas cylinder has the correct gas mixture and is not expired. The standard MSA calibration gas mixture includes: Hydrogen Sulfide (20 ppm), Carbon Monoxide (60 ppm), Pentane Simulant (58% LEL), Oxygen (15.0%), and Nitrogen (Balance).
  2. Attach the 0.25 L/min Regulator to the calibration gas cylinder. Ensure the regulator's valve is open slightly to purge any residual air before fully tightening it onto the cylinder. This prevents moisture from entering the cylinder.
  3. Connect the tubing from the regulator to the calibration adapter.
  4. Attach the calibration adapter to the MSA ALTAIR 4XR detector. The adapter should securely cover the sensor inlets.
  5. From the normal operating mode, press and hold the right button until the display shows "SPAN CAL?".
  6. Press the middle button to confirm "Span Cal". The unit will prompt for gas application.
  7. Immediately turn on the gas flow from the cylinder by opening the regulator valve. The detector will begin to read the gas concentrations.
  8. Monitor the display. The values for each gas (LEL, O2, H2S, CO) should stabilize near the concentrations listed on your calibration gas cylinder. The unit will indicate "SPAN PASS" when calibration is successful.
  9. Once "SPAN PASS" is displayed, turn off the gas flow and remove the calibration adapter and tubing from the detector.
Worker using MSA ALTAIR 4XR Multigas Detector in a confined space

Figure 2: The MSA ALTAIR 4XR Multigas Detector in use, demonstrating its compact size and clear display for field applications.

Operazione

After successful calibration, the ALTAIR 4XR is ready for use. The large, clear display shows real-time gas concentrations. The unit continuously monitors the environment and will activate audible, visual (LEDs), and vibrating alarms if gas levels exceed predefined thresholds or if a man-down event is detected via MotionAlert.

Manutenzione

Regular maintenance is crucial for the longevity and accuracy of your MSA ALTAIR 4XR. Keep the device clean and free from debris. Periodically inspect the sensor inlets for blockages. The unit is compatible with MSA GALAXY GX2 Automated Test System for simplified and automated bump testing and calibration, which also helps in managing data and records.

Sensors are designed for long life but may require replacement over time. The device will provide an "end-of-sensor-life" warning. Replacement MSA XCell Sensors are available and can be easily installed in the plug-and-play slots.

Risoluzione dei problemi

If the device fails a bump test or calibration, first ensure that the calibration gas cylinder is not expired and contains the correct mixture. Check all connections for leaks. If sensor readings are erratic or consistently off, the sensor may be poisoned or at the end of its life and require replacement. For persistent issues, refer to the comprehensive troubleshooting guide in the full product manual or contact MSA support.

Specifiche

SpecificazioneValore
MarcaMSA
StileO2, H2S, CO
Fonte di alimentazioneAlimentato a batteria
ColoreNERO
Dimensioni del prodotto1.37"P x 3"L x 4.4"A
Peso dell'articolo0.51 libbre (8.1 once)
AllarmeUdibile, visivo
Umidità di esercizio95 percento
Valutazione della temperatura superiore50 gradi Celsius
Tipo di sensoreCatalytic, Electrochemical
Numero di articoli1
ProduttoreMSA
Numero di parte10178557
Numero modello articolo10178557
Data prima disponibilità25 gennaio 2018

Garanzia e supporto

This product is covered by a 4-year warranty. For more information regarding warranty claims or technical support, please visit the official MSA website or contact their customer service. Ensure to register your product to activate the warranty and receive important updates.

For additional assistance, you may also refer to the comprehensive product manual provided with your device or contact a certified MSA service center.

Documenti correlati - 10178557

Preview Manuale operativo del rilevatore multigas MSA ALTAIR 4XR
Manuale operativo completo per il rilevatore multigas MSA ALTAIR 4XR, che comprende norme di sicurezza, descrizione del dispositivo, funzionamento, manutenzione, dati tecnici e informazioni per l'ordinazione.
Preview Sistema di prova automatizzato MSA GALAXY GX2 per rilevatori di gas
Il sistema di test automatizzato MSA GALAXY GX2 offre test e calibrazione semplici e intelligenti per i rilevatori monogas MSA ALTAIR e ALTAIR PRO e per i rilevatori multigas ALTAIR 4XR e ALTAIR 5X. È dotato di un'interfaccia intuitiva, test automatizzati e funzionalità complete di gestione della flotta.
Preview Manuale operativo del rilevatore multigas MSA ALTAIR 5X e 5XIR
Manuale operativo completo per i rilevatori multigas MSA ALTAIR 5X e ALTAIR 5XIR, che copre le norme di sicurezza, il funzionamento, la manutenzione, le specifiche tecniche e la risoluzione dei problemi per il rilevamento di gas in ambienti industriali.
Preview Sonda per pompa MSA ALTAIR: rilevatore di gas durevole per ambienti pericolosi
Scopri la sonda per pompa MSA ALTAIR, uno strumento di rilevamento gas robusto e affidabile. Scopri le sue caratteristiche principali, le specifiche tecniche, le certificazioni e le informazioni per l'ordine per applicazioni di sicurezza industriale.
Preview Manuale operativo del sistema di test automatizzato MSA Galaxy GX2
Manuale operativo per il sistema di test automatizzato MSA Galaxy GX2, che descrive in dettaglio installazione, configurazione, funzionamento, manutenzione e risoluzione dei problemi per i test dei rilevatori di gas.
Preview Manuale operativo del rilevatore di gas singolo MSA ALTAIR Pro - Guida alla sicurezza e all'uso
Questo manuale operativo fornisce istruzioni dettagliate, linee guida di sicurezza, procedure di calibrazione e risoluzione dei problemi per il rilevatore di gas singolo MSA ALTAIR Pro. Scopri come utilizzare e manutenere efficacemente il tuo strumento di rilevamento gas.