DAKASON WP-30D-50

DAKASON 30W LED Wall Pack Instruction Manual

Model: WP-30D-50

Introduzione

Thank you for choosing the DAKASON 30W LED Wall Pack. This product is designed to provide efficient and reliable outdoor lighting with features such as a dusk-to-dawn photocell and an adjustable head. This manual provides essential information for safe installation, operation, and maintenance of your LED wall pack. Please read it thoroughly before installation and keep it for future reference.

DAKASON 30W LED Wall Pack with adjustable head installed on a building exterior

Image: DAKASON 30W LED Wall Pack with adjustable head installed on a building exterior, illuminating the area below.

Informazioni sulla sicurezza

Durante l'installazione e il funzionamento, osservare le seguenti precauzioni di sicurezza:

  • AVVERTIMENTO: Rischio di scossa elettrica. Scollegare l'alimentazione dal fusibile o dall'interruttore automatico prima dell'installazione o della manutenzione.
  • L'installazione deve essere eseguita da un elettricista qualificato, nel rispetto di tutti i codici e le ordinanze elettriche locali.
  • Garantire la fornitura voltage is compatible with the fixture's requirements (100-277V AC).
  • Non maneggiare l'apparecchio con le mani bagnate o quando si è in piedi su superfici bagnate o bagnate.amp superfici.
  • This fixture is designed for outdoor use and is IP65 rated for wet locations.
  • Do not attempt to modify or disassemble the fixture beyond what is described in this manual.

Contenuto della confezione

Verificare che tutti i componenti siano presenti prima di iniziare l'installazione:

  • DAKASON 30W LED Wall Pack Fixture (x2 for 2-pack)
  • Photocell (pre-installed)
  • Non-photocell cover (for disabling photocell function)
  • Materiale di montaggio (viti, dadi per cavi)
  • Manuale di istruzioni

Caratteristiche del prodotto

  • Efficienza energetica: Consumes 30 watts, replacing 100-150 watt metal halide lights, saving up to 80% energy.
  • Built-in Photocell: Automatically turns the light on at dusk and off at dawn. Can be converted to non-photocell operation.
  • Testa regolabile: Fixture angle can be adjusted 0-90 degrees for precise light direction.
  • Costruzione durevole: Made of die-cast aluminum housing and tempered glass lens, IP65-rated waterproof and vibration resistant.
  • Lunga durata: Maintenance-free LEDs with 50,000 hours of life.

Configurazione e installazione

Follow these steps for proper installation of your DAKASON LED Wall Pack. Ensure power is disconnected before starting.

1. Montaggio dell'apparecchio

  1. Choose a suitable mounting location on a wall or vertical surface, ensuring it can support the fixture's weight.
  2. Securely attach the mounting plate to the junction box or wall using appropriate screws and anchors (not included, if required for your surface).
  3. Ensure the mounting plate is oriented correctly, typically with 'UP' arrow pointing upwards, to allow proper hinge function.
Diagram showing the junction box mounting process for the LED wall pack

Image: Diagram illustrating the junction box mounting process, showing the fixture opened to reveal wiring and the separate mounting plate.

2. Collegamenti elettrici

  1. Connect the fixture's black wire to the supply's live/hot wire.
  2. Connect the fixture's white wire to the supply's neutral wire.
  3. Connect the fixture's green/ground wire to the supply's ground wire.
  4. Use appropriate wire nuts to secure all connections. Ensure connections are tight and insulated.
  5. Infila con attenzione tutti i cavi nella scatola di giunzione.

3. Fissaggio dell'apparecchio

  1. Attach the fixture body to the mounted plate, ensuring it is securely hinged.
  2. Close the fixture and tighten any securing screws to ensure a watertight seal.
DAKASON LED Wall Pack installed on a building during heavy rain, demonstrating its IP65 waterproof rating

Image: DAKASON LED Wall Pack installed on a building during heavy rain, demonstrating its IP65 waterproof rating for wet locations.

4. Photocell Configuration (Optional)

The fixture comes with a pre-installed photocell for dusk-to-dawn operation. If you prefer to control the light with a wall switch, you can replace the photocell with the included non-photocell cover.

  1. To disable the photocell, carefully disassemble the housing of the lamp to access the photocell.
  2. Pull out the existing photocell.
  3. Screw in the non-photocell cover into the opening.
  4. Rimontare il lamp alloggiamento.
Diagram showing how to convert the LED wall pack from photocell to non-photocell operation

Image: Diagram illustrating the steps to convert the LED wall pack from photocell to non-photocell operation by replacing the sensor with a cover.

Istruzioni per l'uso

Funzionamento delle fotocellule

If the photocell is installed, the fixture will automatically turn on when ambient light levels drop (dusk) and turn off when light levels rise (dawn). Ensure the photocell is not obstructed by objects or other light sources, which could interfere with its operation.

Close-up of the photocell sensor on the DAKASON LED Wall Pack, with an icon indicating automatic on/off at dusk/dawn

Image: Close-up of the photocell sensor on the DAKASON LED Wall Pack, illustrating its function to automatically turn on at dusk and off at dawn.

Regolazione della testa della lampada

The fixture's head can be adjusted to direct light as needed. Loosen the adjustment screw on the side of the fixture, pivot the light head to the desired angle (0-90 degrees), and then securely tighten the screw to lock it in place.

Diagram showing the 0-90 degree adjustable head feature of the LED wall pack

Image: Diagram illustrating the 0-90 degree adjustable head feature of the LED wall pack, showing the range of motion.

Manutenzione

The DAKASON LED Wall Pack is designed for minimal maintenance. However, periodic cleaning can help maintain optimal performance.

  • Pulizia: Ensure the power is off before cleaning. Wipe the exterior of the fixture with a soft, damp panno. Non utilizzare detergenti abrasivi o solventi, poiché potrebbero danneggiare la finitura o la lente.
  • Ispezione: Periodically check the fixture for any signs of damage, loose connections, or wear. Address any issues promptly.
  • I LED sono integrati e non sostituibili dall'utente.

Risoluzione dei problemi

If you encounter issues with your LED Wall Pack, refer to the following common problems and solutions:

ProblemaPossibile causaSoluzione
La luce non si accendeNessuna alimentazione
Cablaggio difettoso
Photocell malfunction (if installed)
Controllare l'interruttore automatico e i collegamenti di alimentazione.
Verificare che i collegamenti elettrici siano saldi.
Ensure photocell is not obstructed or try replacing it with the non-photocell cover to test.
La luce rimane accesa durante il giornoPhotocell obstructed or receiving insufficient light
Malfunzionamento della fotocellula
Clear any obstructions from the photocell. Ensure it is exposed to natural daylight.
Test with the non-photocell cover.
La luce tremolaCollegamento del cablaggio allentato
Voltage fluttuazioni
Controllare e fissare tutti i collegamenti elettrici.
Consult a qualified electrician to check power supply stability.

Specifiche

Dimensions diagram for the DAKASON 30W LED Wall Pack, showing length, width, and height measurements

Image: Dimensions diagram for the DAKASON 30W LED Wall Pack, showing length, width, and height measurements.

AttributoValore
MarcaDAKASON
Numero di modelloWP-30D-50
Cosatage30 Watt
Luminosità3300 lumen
Temperatura del colore5000 Kelvin (bianco freddo)
Voltage100-277 Volt (CA)
MaterialeAlluminio pressofuso, vetro temperato
Dimensioni (L x P x A)6.6" x 7.9" x 4.3"
Peso dell'articolo4 libbre
Grado di protezione IPIP65 (impermeabile)
Caratteristiche specialiDusk-to-Dawn Photocell, Adjustable Head, Full Cut-Off, Instant On, Not Dimmable, Shatter Resistant
CertificazioniETL quotato
Codice UPC766832159971

Informazioni sulla garanzia

This DAKASON LED Wall Pack comes with a Garanzia di 5 anno. The warranty is provided by the seller. Please retain your proof of purchase for any warranty claims.

Assistenza clienti

For any questions, concerns, or issues regarding your DAKASON LED Wall Pack, please contact us through the Amazon Buyer-Seller Messaging Service. Our support team is available to assist you.

Documenti correlati - WP-30D-50

Preview Sunco Lighting LED Mini Wall Pack 26W - Specifiche e guida all'installazione
Detailed product information for the Sunco Lighting LED Mini Wall Pack (26W, 5000K). Includes features like built-in photocell, 0-10V dimming, durable construction, and comprehensive installation instructions. Suitable for commercial and industrial applications.
Preview Lampada da parete a LED - Illuminazione per esterni ad alta efficienza e durevole
Specifiche dettagliate, caratteristiche, guida all'installazione e dati di prova per le luci da parete a LED del produttore di luci a LED, disponibili da 60 W a 150 W con CCT regolabile e watttage. Presenta un grado di impermeabilità IP65 e una garanzia di 5 anni.
Preview LED Parking Lot Light Installation Instructions and Wiring Guide
Comprehensive installation guide for LED Parking Lot Lights, covering safety, electrical connections, wiring diagrams, and mounting procedures for pole or cobra head and round pole installations. Includes input cable specifications and dimming function details.
Preview Guida all'installazione del pacchetto parete GKOLED Full Cutoff
Questa guida all'installazione fornisce istruzioni dettagliate per il montaggio e il cablaggio del GKOLED Full Cutoff Wall Pack, comprese avvertenze di sicurezza, procedure di montaggio della scatola di giunzione e del condotto, installazione della fotocellula, suggerimenti per la risoluzione dei problemi e schemi elettrici.
Preview Olympia Electronics GR-490/WP Series - Apparecchi di illuminazione di emergenza stagni - Manuale utente e guida all'installazione
Questo documento fornisce specifiche tecniche dettagliate, istruzioni di installazione, indicazioni di montaggio, dettagli operativi e informazioni sulla garanzia per le serie GR-490/WP, GR-491/WP, GR-492/WP e GR-493/WP di apparecchi di illuminazione di emergenza da soffitto, impermeabili, autodiagnostici e non soggetti a manutenzione.
Preview Guida all'installazione e alla manutenzione della trappola per grassi Wells WP-GT-50
Guida completa per la trappola per grassi Wells WP-GT-50, che copre installazione, manutenzione e dimensionamento. Le caratteristiche includono una capacità di 50 GPM, una capacità di grasso di 100 libbre, una struttura in acciaio al carbonio e la certificazione PDI.