1. Introduzione
This manual provides detailed instructions for the safe and effective use of your ThruNite T10 II EDC Flashlight. Please read this manual thoroughly before operating the device and retain it for future reference.
2. Prodotto finitoview
The ThruNite T10 II is a compact and lightweight Everyday Carry (EDC) flashlight designed for various indoor and outdoor activities. It features a magnetic tailcap for hands-free operation, multiple lighting modes, and is powered by either a 14500 or AA battery.

Image 1: ThruNite T10 II EDC Flashlight, showcasing its compact design and side switch.
3. Contenuto della confezione
Verifica che tutti gli articoli siano presenti nel tuo pacco:
- 1 x ThruNite T10 II Flashlight
- 2 O-ring di ricambio
- 1 clip da tasca

Image 2: Contents of the ThruNite T10 II package, including the flashlight, spare O-rings, and pocket clip.
4. Impostazione
4.1 Installazione della batteria
The ThruNite T10 II can be powered by one 14500 rechargeable battery or one AA battery (not included). For optimal performance and maximum output, a 14500 battery is recommended.
- Svitare la testa della torcia in senso antiorario per aprire il vano batteria.
- Inserire la batteria con il polo positivo (+) rivolto verso la testa della torcia.
- Riavvitare la testa in senso orario fino a quando non è ben serrata.
Nota: Assicurarsi che la polarità della batteria sia corretta per evitare danni alla torcia.
5. Istruzioni per l'uso
The ThruNite T10 II features a side switch for all operations.
- Attiva/disattiva: Basta un solo clic sull'interruttore laterale per accendere o spegnere la luce.
- Modalità Lucciola: When the light is off, press and hold the switch to activate Firefly mode.
- Cycle Modes (Low/Medium): When the light is on, press and hold the switch to cycle through Low and Medium modes.
- Modalità alta: Double click the switch from any mode to activate High mode.
- Modalità strobo: Double click again from High mode to activate Strobe mode.
Nota: The flashlight does not have mode memory and will always start in Medium mode when turned on with a single click, unless Firefly mode is activated by a long press from off. To reset the mode order to Medium, leave the light off for approximately 1.5 to 2 seconds.

Image 3: Visual guide to operating the ThruNite T10 II, showing the side switch and mode activation.
6. Caratteristiche e specifiche
6.1 Caratteristiche principali
- Compatto e leggero: Designed for easy portability and everyday carry.
- Terminale magnetico: Consente il fissaggio a mani libere su superfici metalliche.
- Modalità versatili: Includes Firefly, Low, Medium, High, and Strobe modes for various lighting needs.
- Compatibilità con doppia batteria: Operates with either a 14500 or AA battery.
- Elevata potenza: Up to 550 lumens when powered by a 14500 battery.
- Costruzione durevole: Made from aluminum for robust performance.
- Resistenza all'acqua: Grado di protezione IPX8 contro l'immersione in acqua.
6.2 Specifiche
| Attributo | Dettaglio |
|---|---|
| Marca | Attraverso la notte |
| Modello | T10 II |
| Sorgente luminosa | LED CREE XP-G2 |
| Max Output (14500) | 550 lumen |
| Max Output (AA) | 160 lumen |
| Fonte di alimentazione | 1x 14500 or 1x AA Battery |
| Materiale | Alluminio |
| Peso | 40 grammi (senza batteria) |
| Dimensioni | Approximately 87mm (length) x 19mm (head diameter) |
| Resistenza all'acqua | IPX8 (sommergibile fino a 2 metri) |

Image 4: The ThruNite T10 II demonstrating its 550 lumens output.

Image 5: The compact size of the ThruNite T10 II, showing its 87mm length and 19mm head diameter.

Image 6: The ThruNite T10 II demonstrating its IPX8 water resistance.

Image 7: The magnetic tailcap feature of the ThruNite T10 II, allowing for hands-free use.
7. Manutenzione
- Pulizia: Pulire regolarmente le filettature e gli O-ring con un panno pulito.
- Lubrificazione: Applicare periodicamente grasso al silicone sugli O-ring per mantenerne la resistenza all'acqua.
- Cura della batteria: Rimuovere le batterie se la torcia non verrà utilizzata per un periodo prolungato per evitare perdite.
- Cura delle lenti: Pulisci la lente con un panno morbido e privo di lanugine. Evita materiali abrasivi.
8. Risoluzione Dei Problemi
If your flashlight is not functioning correctly, please refer to the following common issues and solutions:
- La luce non si accende:
- Controllare che la batteria sia inserita correttamente, con il polo positivo (+) rivolto verso la testa.
- Ensure the head is screwed on tightly.
- Replace the battery with a new or fully charged one.
- La luce è fioca o tremolante:
- The battery may be low. Replace or recharge the battery.
- Pulire i contatti e le filettature della batteria.
Se il problema persiste dopo aver provato questi passaggi, contatta l'assistenza clienti.
9. Garanzia e supporto
ThruNite products are manufactured to high-quality standards. For warranty information or technical support, please visit the official ThruNite webo contattare direttamente il servizio clienti. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.





