This manual provides essential information for the installation, operation, maintenance, and troubleshooting of the IHP OEM Superior Pilot Assembly, model H2328, designed for natural gas (NG) fireplaces, stoves, and inserts. This is an original equipment manufacturer (OEM) part, ensuring compatibility and performance with specified IHP and Lennox models.

IHP OEM Superior Pilot Assembly - NG (H2328)

An image showing the IHP OEM Superior Pilot Assembly for natural gas fireplaces and stoves. The assembly includes the pilot burner, thermocouple, and igniter, with copper tubing coiled above.

Caratteristiche principali:

Compatibilità

The IHP OEM Superior Pilot Assembly (H2328) is a direct replacement for Lennox part number 901047 and is compatible with the following Lennox / IHP Gas Fireplace Models:

Always verify compatibility with your specific appliance model before installation.

Configurazione e installazione

Installation of gas appliance components should only be performed by a qualified service technician. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

Fasi generali di installazione (per tecnici qualificati):

  1. La sicurezza prima di tutto: Ensure the gas supply to the appliance is turned off and the appliance is completely cool. Disconnect electrical power if applicable.
  2. Access the Pilot Assembly: Carefully remove any panels or components necessary to access the existing pilot assembly within the fireplace or stove.
  3. Scollegare il vecchio gruppo: Disconnect the gas line, thermocouple, and igniter wires from the old pilot assembly. Note their positions for reinstallation.
  4. Rimuovere il vecchio assieme: Unfasten and remove the old pilot assembly from its mounting bracket.
  5. Installa nuovo assieme: Mount the new IHP OEM Superior Pilot Assembly (H2328) into the designated position, ensuring it is securely fastened.
  6. Collegare i componenti: Reconnect the gas line, thermocouple, and igniter wires to the new assembly. Ensure all connections are tight and secure. Use new gaskets if provided.
  7. Prova di tenuta: After reassembly, turn on the gas supply and perform a leak test on all connections using an approved leak detection solution.
  8. Operazione di prova: Restore electrical power (if applicable) and test the appliance's ignition and pilot light operation according to the appliance's specific instructions.

Refer to your specific fireplace or stove's service manual for detailed, model-specific installation instructions and safety precautions.

Principi operativi

The pilot assembly is a critical component in the ignition and safety system of your natural gas fireplace or stove. While it does not have direct user controls, understanding its function is important.

Proper operation of the pilot assembly ensures safe and reliable ignition of your gas appliance.

Manutenzione

Regular inspection and maintenance of your pilot assembly can help ensure the longevity and safe operation of your gas appliance. Maintenance should be performed by a qualified service technician.

Manutenzione consigliata:

Always ensure the appliance is cool and the gas supply is off before any inspection or cleaning.

Risoluzione dei problemi

If your gas appliance is experiencing issues related to ignition or pilot light operation, the pilot assembly may be a factor. Always consult a qualified service technician for diagnosis and repair.

Problemi comuni e potenziali cause:

ProblemaCausa potenzialeAction (for qualified technician)
Pilot light won't light.No gas supply, clogged pilot orifice, faulty igniter, faulty gas valve.Check gas supply, clean orifice, test/replace igniter, inspect gas valve.
Pilot light lights but won't stay lit.Weak pilot flame, faulty thermocouple/thermopile, loose connections.Adjust pilot flame, test/replace thermocouple, tighten connections.
Main burner won't ignite after pilot lights.Faulty main gas valve, insufficient pilot flame to ignite main burner.Test main gas valve, adjust pilot flame, ensure proper pilot alignment.
Soot or carbon buildup around pilot.Improper air/gas mixture, dirty pilot orifice.Clean pilot, adjust air shutter (if applicable), check gas pressure.

Do not attempt to repair gas components yourself. Always contact a certified gas technician for any troubleshooting or repairs.

Specifiche

AttributoDettaglio
Numero di modelloH2328
Tipo di partePilot Assembly (OEM)
Tipo di carburanteGas naturale (NG)
MarcaIHP (Innovative Hearth Products)
Sostituisce il numero di parteLennox 901047
Peso dell'articolo2 libbre
Dimensioni del pacco8 x 5 x 4 pollici
ColoreBlack (referring to components, not overall assembly color)

Informazioni sulla garanzia

As an OEM (Original Equipment Manufacturer) part, this IHP pilot assembly is typically covered by the original manufacturer's warranty for replacement parts. Warranty terms can vary based on the manufacturer and the point of purchase.

For specific warranty details, please refer to the documentation provided with your original fireplace or stove, or contact IHP (Innovative Hearth Products) directly. Keep your proof of purchase for any warranty claims.

Assistenza clienti

For technical assistance, installation questions, or service, it is highly recommended to contact a qualified HVAC or gas appliance technician. They have the expertise and tools to safely diagnose and repair issues related to gas components.

You may also visit the official IHP (Innovative Hearth Products) website for product information and authorized service provider locators. When contacting support, please have your appliance model number and the pilot assembly model number (H2328) ready.

Avviso importante sulla sicurezza: Never attempt to modify or repair gas components if you are not a qualified professional. Doing so can result in serious injury, property damage, or death.

Documenti correlati - H2328

Preview Manuale del proprietario e guida all'installazione dei camini Superior DRI3030TEN e DRI2530TEN
Questo manuale completo del proprietario e la guida all'installazione forniscono dettagli essenziali per gli inserti per caminetti a gas a ventilazione diretta Superior Fireplaces DRI3030TEN e DRI2530TEN, coprendo installazione, funzionamento, sicurezza e manutenzione.
Preview Guida all'installazione del kit di montaggio per esterni del gateway Internet 5G | LV55IHP
Guida all'installazione ufficiale per il kit di montaggio per esterni del gateway Internet 5G Verizon (modello LV55IHP). Scopri come installare, collegare e configurare il tuo dispositivo con istruzioni e specifiche dettagliate.
Preview Stufe a gas senza sfiato Superior: Manuale di installazione e funzionamento
Guida completa per l'installazione e l'uso di stufe a gas senza sfiato (senza sfiato) di marca Superior, comprese avvertenze di sicurezza, specifiche del modello e suggerimenti per la risoluzione dei problemi.
Preview Catalogo dei componenti di ventilazione TPI Corporation
Un catalogo completo di componenti per la ventilazione offerti da TPI Corporation, tra cui varie serie di circolatori, ventole e soffianti con numeri di parte e prezzi dettagliati.
Preview Manuale di installazione e funzionamento del telecomando RC-S-TOUCH di Innovative Hearth Products
Guida completa per l'installazione e il funzionamento del sistema di controllo remoto RC-S-TOUCH di Innovative Hearth Products per apparecchi di riscaldamento a gas, che comprende configurazione, funzioni, programmazione e risoluzione dei problemi.
Preview Manuale di installazione e funzionamento del camino elettrico da 27" di Innovative Hearth Products
Questo manuale fornisce istruzioni complete per l'installazione, il funzionamento e la sicurezza dei caminetti elettrici da 27" di Innovative Hearth Products, inclusi i modelli Capella 27, ERT3027, Spark 27 e MPE-27-2. ...