This manual provides essential information for the installation, operation, and maintenance of your IHP OEM FMI ODS Pilot Assembly - LP (J3830). This component is a genuine, certified OEM part designed for use with FMI vent-free gas logs, stoves, fireplaces, and inserts that utilize propane (LP) fuel. It is crucial to read and understand all instructions before proceeding with installation or use to ensure safe and proper function.

IHP OEM FMI ODS Pilot Assembly - LP (J3830)

Image: The IHP OEM FMI ODS Pilot Assembly, showing the pilot tube, thermocouple, and mounting bracket with associated wiring.

Informazioni sulla sicurezza

Always ensure that gas supply is turned off before attempting any installation or maintenance. Installation should only be performed by a qualified service technician. Refer to your appliance's main instruction manual for specific safety warnings and procedures.

Configurazione e installazione

This pilot assembly is a direct replacement part. Before installation, verify that the part number LPG8414 (stamped on the bracket) matches your existing assembly. The thermocouple is soldered onto the pilot tube and is not replaceable separately.

  1. Turn off the gas supply to the appliance and ensure it is completely disconnected.
  2. Carefully disconnect the old pilot assembly, noting the connections for the thermocouple, pilot tube, and igniter wire.
  3. Remove the old assembly from its mounting bracket.
  4. Mount the new IHP OEM FMI ODS Pilot Assembly using the existing bracket and hardware. Ensure it is securely fastened.
  5. Connect the thermocouple, pilot tube, and igniter wire to their respective ports on the gas valve, ensuring all connections are tight and leak-free.
  6. Perform a leak test on all gas connections using an approved leak detection solution.
  7. Restore gas supply and test the pilot light ignition and operation.

For detailed diagrams and specific appliance instructions, consult the original appliance manual.

Istruzioni per l'uso

The pilot assembly is an integral part of the appliance's ignition system. Its operation is typically automatic once installed correctly and the gas supply is on. Refer to your appliance's main operating manual for instructions on lighting the pilot and operating the appliance.

Manutenzione

Regular inspection of the pilot assembly is recommended to ensure proper function and safety. This should be done annually by a qualified technician.

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
Pilot light will not stay lit after releasinpulsante g.Faulty thermocouple or ODS sensor.This pilot assembly is designed with the thermocouple soldered to the pilot tube. If this issue occurs, the entire pilot assembly typically needs replacement. (Refer to Configurazione e installazione).
Pilot light ignites but is weak or yellow.Pilot orifice partially clogged; low gas pressure.Clean pilot orifice. Verify proper gas pressure. Consult a qualified technician.
No pilot ignition.No gas supply; faulty igniter; clogged pilot tube.Check gas supply valve. Inspect igniter for spark. Clean pilot tube. Consult a qualified technician.

For issues not listed, or if troubleshooting steps do not resolve the problem, contact a qualified service technician.

Specifiche

Informazioni sulla garanzia

Specific warranty details for this OEM part are not provided in the product information. Please refer to the original appliance manufacturer's warranty documentation or contact IHP directly for warranty inquiries.

Supporto

For technical assistance or replacement part inquiries, please contact your appliance manufacturer or a certified HVAC/fireplace technician. Always ensure that any service or repair is performed by qualified personnel.

Documenti correlati - J3830

Preview Guida all'installazione del kit di montaggio per esterni del gateway Internet 5G | LV55IHP
Guida all'installazione ufficiale per il kit di montaggio per esterni del gateway Internet 5G Verizon (modello LV55IHP). Scopri come installare, collegare e configurare il tuo dispositivo con istruzioni e specifiche dettagliate.
Preview Catalogo dei componenti di ventilazione TPI Corporation
Un catalogo completo di componenti per la ventilazione offerti da TPI Corporation, tra cui varie serie di circolatori, ventole e soffianti con numeri di parte e prezzi dettagliati.
Preview Manuale del proprietario e guida all'installazione dei camini Superior DRI3030TEN e DRI2530TEN
Questo manuale completo del proprietario e la guida all'installazione forniscono dettagli essenziali per gli inserti per caminetti a gas a ventilazione diretta Superior Fireplaces DRI3030TEN e DRI2530TEN, coprendo installazione, funzionamento, sicurezza e manutenzione.
Preview Manuale di installazione e funzionamento del telecomando RC-S-TOUCH di Innovative Hearth Products
Guida completa per l'installazione e il funzionamento del sistema di controllo remoto RC-S-TOUCH di Innovative Hearth Products per apparecchi di riscaldamento a gas, che comprende configurazione, funzioni, programmazione e risoluzione dei problemi.
Preview Manuale di installazione e funzionamento del camino elettrico da 27" di Innovative Hearth Products
Questo manuale fornisce istruzioni complete per l'installazione, il funzionamento e la sicurezza dei caminetti elettrici da 27" di Innovative Hearth Products, inclusi i modelli Capella 27, ERT3027, Spark 27 e MPE-27-2. ...
Preview Guida all'installazione del kit di conversione PC-DVF32TMHSTPN di Innovative Hearth Products
Istruzioni di installazione dettagliate per il kit di conversione PC-DVF32TMHSTPN di Innovative Hearth Products, che consente la conversione dei caminetti decorativi ventilati serie DVF32TMHST e DVF32TMH PN da gas naturale a gas propano/GPL. Include componenti, utensili, procedure dettagliate e avvertenze di sicurezza.