1. Introduzione

Thank you for choosing the DXQ FL-40 High Pressure Diaphragm Pump. This manual provides essential information for the proper installation, operation, and maintenance of your pump. Please read it thoroughly before use to ensure safe and efficient performance.

DXQ FL-40 High Pressure Diaphragm Pump with clear filter housing

Figure 1: DXQ FL-40 High Pressure Diaphragm Pump

Caratteristiche principali:

  • Materiale durevole: Constructed from high-strength cast iron with powder coating, ensuring waterproof and rust-resistant properties for long-term use.
  • Potente pompa di pressione automatica: A fully automatic self-priming pump with a maximum flow rate of 17 L/min and an inlet PSI set to Max 40PSI (2.76Bar). Operates on 12V AC power.
  • Protezione di sicurezza: Features built-in thermal protection and automatic pressure protection. Designed for long service life with quiet operation and no leakage.
  • Installazione rapida: Compact size, lightweight design, and stable performance facilitate instant assembly.
  • Applicazioni versatili: Suitable for various uses including food and beverage filling, liquid transfer, clean machine requirements, road work, and cooling systems.
Collage of various applications for the pump including kitchen sink, water heater, soda dispenser, agricultural drone, pressure washing, and solar water heater

Figure 2: Wide range of applications for the FL-40 pump

2. Istruzioni di sicurezza

Per evitare lesioni o danni alla pompa, osservare sempre le seguenti precauzioni di sicurezza.

  • Assicurarsi che l'alimentazione corrisponda al volume della pompatage requisiti (12V).
  • Do not operate the pump with damaged wiring or connections.
  • Evitare di far funzionare la pompa a secco per periodi prolungati, poiché ciò potrebbe danneggiarla.
  • Ensure proper ventilation around the pump during operation.
  • Do not use the pump for flammable liquids or in explosive atmospheres.
  • Tenere le mani e gli indumenti larghi lontani dalle parti in movimento.
  • Scollegare l'alimentazione prima di eseguire qualsiasi operazione di manutenzione o risoluzione dei problemi.
  • The pump features built-in thermal protection to prevent overheating. If the pump stops unexpectedly, allow it to cool down before restarting.
Diagram showing the internal motor of the pump with an arrow indicating thermal protection

Figure 3: Thermal Protection feature of the pump

3. Componenti inclusi

The DXQ FL-40 High Pressure Diaphragm Pump package typically includes the following components:

  • 1 x Diaphragm Water Pump
  • 1 x Filtro
  • 3 x Raccordi (vari tipi per il collegamento)
Avvicinamento view of the included filter and various hose fittings

Figure 4: Included filter and fittings

Labeled diagram of the pump showing water outlet connector, stable bracket, pump wire, and water inlet connector

Figure 5: Key components and connections of the pump

4. Configurazione e installazione

Follow these steps for quick and proper installation of your diaphragm pump:

  1. Montaggio: Securely mount the pump in a dry, well-ventilated area using the stable bracket. Ensure it is on a flat, stable surface to minimize vibration.
  2. Collegamento in ingresso: Connect the water inlet hose to the designated inlet port (often labeled 'Inlet' or indicated by an arrow pointing towards the pump). It is recommended to install the included filter on the inlet line to prevent debris from entering the pump.
  3. Collegamento della presa: Connect the water outlet hose to the designated outlet port (often labeled 'Outlet' or indicated by an arrow pointing away from the pump).
  4. Collegamento elettrico: Connect the pump's power wires to a 12V DC power source. Ensure correct polarity (red wire to positive, black wire to negative). It is advisable to install an inline fuse for protection.
  5. Adescamento della pompa (se necessario): While this is a self-priming pump, ensuring the inlet line is filled with water before the first use can aid in faster priming.
  6. Controllare eventuali perdite: After all connections are made, slowly introduce water into the system and check for any leaks at the fittings. Tighten connections as needed.
Diagram showing the pump connected to inlet and outlet hoses with a filter on the inlet, and an arrow indicating water flow direction

Figure 6: Fast assembly and water flow direction

5. Funzionamento

Once installed, operating the DXQ FL-40 pump is straightforward:

  • Avvio della pompa: Ensure all connections are secure and the power source is ready. Apply 12V DC power to the pump. The pump will begin to operate and self-prime.
  • Funzionamento automatico: The pump is designed to automatically turn on when water is demanded (e.g., a faucet is opened) and turn off when the demand stops and pressure builds up in the system.
  • Flusso e pressione: The pump delivers a maximum flow of 17 L/min and maintains pressure up to 40 PSI.
  • Monitoraggio: Periodically check the pump for unusual noises, vibrations, or leaks during operation.

6. Manutenzione

Una manutenzione regolare garantisce la longevità e le prestazioni ottimali della pompa:

  • Pulizia del filtro: Regularly inspect and clean the inlet filter to prevent clogging and maintain optimal flow. Disconnect power, remove the filter housing, clean the mesh screen, and reassemble.
Comparison image showing the included metal filter on the left and a different type of filter on the right

Figure 7: The included metal filter for debris prevention

  • Verifica della connessione: Periodically check all hose and electrical connections for tightness and signs of wear.
  • Preparazione per l'inverno (se applicabile): If the pump is used in an environment where temperatures drop below freezing, ensure it is drained completely or protected with RV antifreeze to prevent damage from freezing water.
  • Pulizia generale: Mantenere la parte esterna della pompa pulita e libera da sporco e detriti.

7. Risoluzione Dei Problemi

Per i problemi più comuni e le relative soluzioni, fare riferimento alla tabella sottostante:

ProblemaPossibile causaSoluzione
La pompa non funzionaNo power; Loose wiring; Blown fuse; Motor faultCheck power supply; Secure connections; Replace fuse; Contact support
Bassa portata o pressioneClogged inlet filter; Kinked or restricted hose; Air in system; Low voltageClean filter; Straighten hose; Bleed air from system; Check power supply
La pompa funziona continuamenteLeak in system; Pressure switch malfunction; Open faucetCheck for leaks and repair; Contact support for pressure switch; Close all faucets
La pompa è rumorosaAir in system; Loose mounting; Debris in pumpBleed air; Secure mounting; Disconnect power and inspect pump (if safe)
Perdite d'acqua dalla pompaLoose fittings; Damaged seals/diaphragmTighten fittings; Contact support for seal replacement

8. Specifiche tecniche

Detailed specifications for the DXQ FL-40 Diaphragm Pump:

SpecificazioneValore
ProduttoreBananaB (DXQ)
Numero di modelloFL-40GMB12V000001
Dimensioni del prodotto36 x 12 x 10 cm (circa 14.2 x 4.7 x 3.9 pollici)
Peso2.4 kg (circa 5.3 libbre)
ColoreNero
StileDiaframma
MaterialeGhisa
Fonte di alimentazione12V CC
Voltage12 Volt
Portata massima17 litri al minuto
Pressione massima40 PSI (2.76 bar)
Altezza massima di sollevamento2 metri
Batterie incluse?NO
Sono necessarie batterie?NO
Image showing the dimensions of the pump: 10 inches long, 4.3 inches wide, and 4.3 inches high

Figure 8: Pump dimensions

Close-up of the pump highlighting its cast iron material construction

Figure 9: Durable Cast Iron Material

9. Informazioni sulla garanzia

For specific warranty terms and conditions, please refer to the product packaging or contact the seller/manufacturer directly. Keep your proof of purchase for any warranty claims.

10. Assistenza clienti

If you encounter any issues not covered in this manual or require further assistance, please contact the seller or manufacturer through the platform where you purchased the product. Provide your model number and a detailed description of the issue for faster service.

Documenti correlati - FL-40GMB12V000001

Preview Manuale di installazione e funzionamento del misuratore di portata serie OMEGA FL-800
Guida completa per il misuratore di portata serie OMEGA FL-800, che comprende installazione, funzionamento, manutenzione, suggerimenti sulla precisione, specifiche, avvertenze di sicurezza, garanzia e informazioni di contatto.
Preview Manuale di assistenza del sistema di alimentazione Nissan Frontier 2007
Manuale di assistenza completo per la Nissan Frontier del 2007, che descrive in dettaglio le procedure per il sistema di alimentazione, comprese precauzioni, preparazione, serbatoio del carburante, pompa del carburante, filtro del carburante e unità sensore. Copre rimozione, installazione, smontaggio, montaggio e specifiche.
Preview Guida e specifiche per la regolazione della rotazione dell'innesto dell'obiettivo Fujinon
Guida dettagliata su come regolare la rotazione degli innesti degli obiettivi delle fotocamere Fujinon, con istruzioni dettagliate e un elenco completo dei modelli di obiettivi con le relative dimensioni del sensore e specifiche di coppia.
Preview Manuale utente Phoenix Contact FL SWITCH serie 1000
Questo manuale utente fornisce una guida completa per la serie FL SWITCH 1000 di switch Ethernet stretti non gestiti di Phoenix Contact. Fornisce informazioni essenziali su sicurezza, installazione, funzionamento, dati tecnici e modalità di ordinazione per vari modelli, garantendone la corretta distribuzione e utilizzo nelle applicazioni di rete industriale.
Preview Manuale utente e specifiche dell'illuminazione intelligente GLEDOPTO RGB+CCT
Istruzioni per l'utente complete e specifiche tecniche per i prodotti di illuminazione intelligente GLEDOPTO RGB+CCT, inclusi telecomandi, proiettori e luci da giardinoamps. Scopri di più su caratteristiche, compatibilità, installazione e funzionamento.
Preview Manuale di installazione e funzionamento del diffusore lineare architettonico Titus FlowBar
Manuale completo di installazione e funzionamento per i diffusori lineari architettonici Titus FlowBar, modelli FL-10, FL-15, FL-20, FL-25 e FL-30. Descrive le procedure per controsoffitti rigidi, controsoffitti acustici e taglio in opera.