1. Introduzione
This manual provides essential information for the safe and correct installation, operation, and maintenance of the Truma Ignition Safety Valve Set, designed for use with Truma S 3002 and S 5002 heaters. Please read these instructions thoroughly before installation and use to ensure proper function and safety.
2. Informazioni sulla sicurezza
AVVERTENZA: installazione, regolazione, alterazione, assistenza o manutenzione non corrette possono causare danni materiali, lesioni o morte. Leggere attentamente le istruzioni di installazione, funzionamento e manutenzione prima di installare o sottoporre a manutenzione questa apparecchiatura.
- L'installazione e la manutenzione devono essere eseguite da un installatore qualificato, da un'agenzia di assistenza o da un fornitore di gas.
- Always shut off the gas supply before performing any maintenance or service.
- Assicurare una ventilazione adeguata durante l'uso di apparecchi a gas.
- Check for gas leaks after installation or service using an approved leak detection solution.
- Non utilizzare fiamme libere per verificare eventuali perdite di gas.
3. Contenuto della confezione
Prima di procedere con l'installazione, verificare che tutti i componenti siano presenti e integri.
- Ignition protection valve
- Guarnizione di tenuta
- Noce
- Anello di taglio
- Associated wiring and mounting brackets (as pictured)

Figura 1: Components of the Truma Ignition Safety Valve Set. This image displays the main valve assembly with attached wiring, a flexible hose, an O-ring, a nut, a cutting ring, and two metal mounting brackets.
4. Configurazione e installazione
This ignition safety valve set is designed for specific Truma S 3002 and S 5002 heaters. Refer to your heater's primary manual for detailed instructions on accessing the valve area.
- Preparazione: Ensure the gas supply to the heater is completely shut off and the system has cooled down. Disconnect any electrical power to the heater.
- Rimuovere la vecchia valvola (se applicabile): Carefully disconnect the gas lines and electrical connections from the existing safety valve. Note the orientation and connections for proper reassembly.
- Installare la nuova valvola:
- Attach the new ignition safety valve to the heater using the provided mounting brackets. Ensure it is securely fastened.
- Connect the gas inlet and outlet lines. Use the new O-ring, nut, and cutting ring for a secure, leak-free connection. Tighten connections to manufacturer specifications, but do not overtighten.
- Connect the electrical wiring from the valve to the heater's control system. Ensure correct polarity and secure connections.
- Prova di tenuta: After installation, slowly turn on the gas supply. Apply an approved gas leak detection solution to all gas connections. Bubbles indicate a leak. If a leak is detected, immediately shut off the gas supply and re-tighten the connection. Repeat the leak test until no bubbles appear.
- Electrical Test: Restore electrical power to the heater and perform a functional test according to the heater's operating instructions.
Nota: If you are unsure about any step of the installation process, consult a qualified gas appliance technician.
5. Funzionamento
The Truma Ignition Safety Valve is an integral component of your Truma S 3002/5002 heater's safety system. It operates automatically to ensure safe gas flow.
- When the heater is switched on and an ignition signal is present, the safety valve opens to allow gas to flow to the burner.
- If the flame extinguishes unexpectedly (e.g., due to wind or gas supply interruption), the safety valve will automatically close the gas supply within a specified timeframe, preventing unburnt gas from accumulating.
- This valve does not require manual operation during normal use. Its function is entirely automatic and safety-critical.
6. Manutenzione
Regular maintenance of your Truma heater system, including the ignition safety valve, is crucial for safe and efficient operation. While the safety valve itself requires minimal direct user maintenance, periodic checks are recommended.
- Ispezione annuale: It is recommended to have your entire Truma heating system, including the gas lines and safety valve, inspected annually by a qualified technician.
- Controllo visivo: Periodically inspect the valve and its connections for any signs of corrosion, damage, or loose fittings.
- Pulizia: Keep the area around the valve clean and free from dust or debris. Do not use harsh chemicals or abrasive cleaners.
- Sostituzione dei componenti: If any part of the safety valve set appears damaged or worn, it must be replaced with genuine Truma spare parts by a qualified technician.
7. Risoluzione Dei Problemi
If your Truma heater is not functioning correctly, and you suspect an issue with the ignition safety valve, consider the following:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Heater does not ignite or repeatedly fails to ignite. | No gas supply, faulty ignition, or safety valve not opening. |
|
| Heater ignites but flame extinguishes quickly. | Insufficient gas pressure, faulty thermocouple/flame sensor, or safety valve closing prematurely. |
|
| Odore di gas. | Perdita di gas. |
|
Importante: Do not attempt repairs on gas components unless you are a qualified and certified technician. Always prioritize safety.
8. Specifiche
- Tipo di prodotto: Ignition Safety Valve Set
- Marca: Truma
- Compatibilità del modello: Truma S 3002, Truma S 5002 heaters
- Numero parte: FRA309492
- Materiale: Plastic (valve body may contain metal components)
- Dimensioni (L x P x A): Circa 2.76 x 6.3 x 2.76 pollici (7 x 16 x 7 cm)
- Peso dell'articolo: Circa 14.8 once (420 g)
- Finitura esterna: Dipinto
- Dimensioni della connessione di ingresso: 1.6E+2 Millimeters (160mm)
- Tipo di collegamento di ingresso: Cutting Ring
- Dimensioni della connessione di uscita: 16 millimetri
- Tipo di collegamento della presa: Cutting Ring
- Numero di porte: 2
- Specifiche soddisfatte: CE
9. Informazioni sulla garanzia
Specific warranty terms for the Truma Ignition Safety Valve Set are provided by the manufacturer, Truma. Please refer to the warranty documentation included with your original purchase or visit the official Truma websito per informazioni dettagliate sulla copertura della garanzia, sulla durata e sulle procedure di reclamo.
Retain your proof of purchase for warranty purposes.
10. Assistenza clienti
For technical assistance, spare parts, or service inquiries, please contact Truma customer support or an authorized Truma service center.
You can find contact information and a list of authorized service partners on the official Truma websito: http://www.truma.com
When contacting support, please have your product model number (FRA309492) and purchase details ready.