1. Introduzione
This manual provides essential information for the safe and efficient operation, installation, and maintenance of the TRANE 4TTA3060D4000DA ACC-12247 Commercial Central Air Conditioner Condenser. This unit is a 5-ton commercial condenser designed for specific applications. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures.
Informazioni sulla sicurezza:
- Scollegare sempre l'alimentazione prima di eseguire interventi di manutenzione sull'unità.
- Installation and service should only be performed by qualified, licensed HVAC technicians.
- Assicurare la corretta messa a terra e i collegamenti elettrici secondo le normative elettriche locali e nazionali.
- This unit operates on 460 Volt, 3-phase power. Incorrect voltage can cause severe damage or injury.
- Refrigerant R-410A is used in this system. Handle with care and follow all safety guidelines for refrigerants.
2. Configurazione e installazione
The TRANE 4TTA3060D4000DA ACC-12247 condenser unit requires professional installation due to its commercial nature and specific electrical requirements. This unit has been previously installed but never started, indicating it is in 'as new' condition but requires proper commissioning.
2.1 Selezione del sito
Choose a location that allows for adequate airflow around the unit and provides sufficient space for maintenance access. Ensure the mounting surface is level and capable of supporting the unit's weight.
2.2 collegamenti elettrici
This unit requires a 460 Volt, 3-phase electrical supply. All wiring must comply with local and national electrical codes. Incorrect voltage or phase connection will damage the unit and void the warranty. A dedicated circuit breaker is required.
2.3 Tubazioni del refrigerante
Connect the refrigerant lines (liquid and suction) to the appropriate ports on the condenser. Ensure all connections are leak-free. The unit is shipped with a dry gas charge for testing and shipping purposes; it must be properly evacuated and charged with R-410A refrigerant by a certified technician during installation.

An image showing the exterior of the TRANE 4TTA3060D4000DA ACC-12247 commercial central air conditioner condenser unit. The unit is gray, rectangular with rounded corners, and features louvered panels on its sides for airflow. A fan grille is visible on the top surface, indicating the fan's location. The Trane logo is visible on one side.
3. Istruzioni per l'uso
The TRANE 4TTA3060D4000DA ACC-12247 is a condenser unit, which is part of a larger central air conditioning system. It works in conjunction with an indoor evaporator coil and a thermostat to provide cooling. Operation is typically controlled by the building's central thermostat or building management system.
3.1 Avvio iniziale
- Ensure all electrical and refrigerant connections are secure and verified by a qualified technician.
- Verify the system has been properly evacuated and charged with the correct amount of R-410A refrigerant.
- Restore power to the unit at the main disconnect.
- Set the thermostat to a cooling mode and a temperature below the ambient temperature to initiate a cooling cycle.
- Monitor the unit for proper operation, including fan rotation and compressor engagement.
3.2 Funzionamento normale
Once started, the condenser unit will cycle on and off as dictated by the thermostat's demand for cooling. The outdoor fan will draw air over the condenser coil to dissipate heat from the refrigerant.
4. Manutenzione
Regular maintenance is crucial for the longevity and efficient operation of your TRANE condenser unit. All maintenance should be performed by a qualified HVAC technician.
4.1 Routine Checks (Monthly/Quarterly)
- Bobine pulite: Inspect and clean the outdoor condenser coils to remove dirt, leaves, and debris. Blocked coils reduce efficiency.
- Rimozione detriti: Ensure the area around the unit is free of obstructions, vegetation, and debris that could impede airflow.
- Ispezionare le pale del ventilatore: Check for any damage or imbalance in the fan blades.
4.2 Professional Service (Annually)
- Controllo del livello del refrigerante: Verify proper refrigerant charge. Low or high charge can impact performance and damage the compressor.
- Collegamenti elettrici: Inspect all electrical connections for tightness and signs of wear.
- Compressor Health: Check compressor operation, including voltage e ampera.
- Controllo del condensatore: Test the start and run capacitors.
- Drenaggio: Ensure proper condensate drainage from the indoor evaporator coil (part of the overall system).
5. Risoluzione Dei Problemi
This section provides general troubleshooting guidance. For complex issues or repairs, always contact a qualified HVAC technician.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'unità non si avvia | No power; Thermostat setting incorrect; Blown fuse/tripped breaker; Safety switch tripped | Check power supply; Adjust thermostat; Reset breaker/replace fuse; Consult technician for safety switch |
| Unit runs but no cooling | Low refrigerant; Dirty coils; Compressor issue; Fan motor issue | Contact technician for refrigerant charge; Clean coils; Consult technician for compressor/fan motor repair |
| Loud noises from unit | Loose fan blades; Compressor issue; Debris in fan | Inspect fan; Contact technician for compressor diagnosis; Remove debris |
| High energy bills | Dirty coils; Low refrigerant; Improper sizing; Poor insulation | Perform routine maintenance; Consult technician for system optimization |
6. Specifiche
Detailed specifications for the TRANE 4TTA3060D4000DA ACC-12247 Commercial Condenser Unit:
- Modello: 4TTA3060D4000DA
- Numero di magazzino: ACC-12247
- Tipo di apparecchiatura: Condensatore
- Cooling Size: 5 tonnellate
- Tipo di refrigerante: R-410A
- Elettrica: 460 Volt, 3-Phase
- Anno di fabbricazione: 2017
- Tipo di condensatore: Straight Cool
- Equipment Condition: As New (previously installed but never started)
- Produttore: TRANANTE
- Peso del prodotto: 260 libbre (117.93 kg)
- Tipo di applicazione: Commerciale
- ASIN: B07L392HFM
7. Garanzia e supporto
For specific warranty information regarding your TRANE 4TTA3060D4000DA ACC-12247 Commercial Condenser Unit, please refer to the documentation provided at the time of purchase or contact your authorized Trane dealer or the seller directly. Warranty terms typically cover manufacturing defects and may vary based on installation and registration.
For technical support, service, or to locate an authorized Trane service provider, please visit the official Trane website or contact their customer service line. Always provide your model and serial number when seeking support.