1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the CISA Serie 604 Rack and Pinion Door Closer, model 60450.03.97. This door closer is designed to provide effective and reliable door control for both residential and commercial applications, ensuring smooth and secure door closure.

The CISA Serie 604 features adjustable closing force (EN 2-4) and is suitable for doors weighing up to 85 kg and up to 1100 mm in width. It offers independent adjustments for closing speed and final latching action, ensuring optimal performance in various environments. Its compact design allows for seamless integration with diverse architectural styles.

2. Informazioni sulla sicurezza

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in injury or damage to the product or property.

  • Prima di iniziare l'installazione, assicurarsi che tutti i componenti siano presenti e integri.
  • Durante l'installazione utilizzare sempre utensili e dispositivi di sicurezza adeguati.
  • Do not attempt to modify the door closer. Any modifications will void the warranty and may compromise safety.
  • Tenere bambini e animali domestici lontani dall'area di installazione.
  • Ensure the door closer is securely fastened to prevent accidental detachment.
  • Adjustments should only be made by qualified personnel to prevent improper operation or damage.

3. Prodotto finitoview e componenti

The CISA Serie 604 door closer consists of the main body, an arm assembly, and adjustment valves. It is supplied with all necessary fixing screws and a mounting template for straightforward installation.

Avvicinamento view of the CISA Serie 604 door closer showing the adjustment screws for closing speed and final latching.

Figura 1: Avvicinamento view of the CISA Serie 604 door closer, highlighting the two adjustment screws for precise control over closing speed and final latching action. The CISA logo is visible at the bottom left.

I componenti chiave includono:

  • Corpo principale: Contains the rack and pinion mechanism and hydraulic fluid.
  • Assemblaggio del braccio: Connects the door closer to the door frame or door.
  • Adjustment Valves: Two independent valves for controlling closing speed and final latching.
  • Mounting Plate/Template: For accurate positioning during installation.
  • Viti di fissaggio: For secure attachment.

4. Configurazione e installazione

The CISA Serie 604 door closer is designed for quick installation and can be mounted on both right-hand and left-hand doors, for both pull-side and push-side applications. A mounting template is provided to simplify the process.

4.1. Controlli pre-installazione

  • Verify the door weight and width are within the specified limits (max 85 kg, max 1100 mm).
  • Determine the mounting position (door or frame) and orientation (pull-side or push-side) based on your door type and desired opening angle.
  • Ensure the mounting surface is strong enough to support the door closer.

4.2. Passaggi di montaggio

  1. Posizionamento: Use the provided mounting template to mark the drilling points on the door or door frame.
  2. Perforazione: Praticare dei fori pilota nelle posizioni contrassegnate.
  3. Collegare il corpo principale: Securely fasten the main body of the door closer using the supplied fixing screws.
  4. Montare il braccio: Attach the arm assembly to the door closer and the door frame/door, following the specific instructions for your chosen mounting type (pull-side or push-side). Ensure all connections are tight.
Technical drawing of the CISA Serie 604 door closer with detailed dimensions in millimeters.

Figura 2: Technical drawing illustrating the dimensions and mounting points of the CISA Serie 604 door closer. All measurements are in millimeters, providing precise guidance for installation.

5. Istruzioni per l'uso e regolazioni

The CISA Serie 604 door closer allows for independent adjustment of two key functions: closing speed and final latching action. These adjustments are crucial for optimal door performance and safety.

5.1. Adjustment Valves

The door closer features two adjustment valves, typically labeled '1' and '2' or similar, as shown in Figure 1. These valves control different phases of the door's closing cycle:

  • Valve 1 (Closing Speed): Controls the speed of the door from its fully open position until approximately 15 degrees from closure. Turning the valve clockwise decreases the speed (slower closing), and counter-clockwise increases the speed (faster closing).
  • Valve 2 (Final Latching Action / Backcheck): Controls the speed of the door for the final 15 degrees of closure, ensuring the door latches securely without slamming. It can also provide a backcheck function to prevent the door from opening too quickly or forcefully. Turning clockwise decreases the latching speed/increases backcheck, counter-clockwise increases latching speed/decreases backcheck.
Diagram showing the adjustment sectors for closing speed (green) and final latching action (red) on the CISA Serie 604 door closer.

Figura 3: This diagram illustrates the two distinct adjustment sectors. The green sector (up to 80 degrees) represents the main closing speed, while the red sector (final 15 degrees) indicates the final latching action, both independently adjustable.

5.2. Making Adjustments

  • Use a suitable screwdriver to turn the adjustment valves.
  • Make small adjustments (quarter turns) at a time and test the door's closing action after each adjustment.
  • Do not overtighten or loosen the valves excessively, as this can damage the hydraulic mechanism.
  • Aim for a smooth, controlled closing action that allows the door to latch without excessive force or speed.

6. Manutenzione

The CISA Serie 604 door closer is designed for long-term, maintenance-free operation. However, periodic checks can help ensure its continued performance and extend its lifespan.

  • Ispezione annuale: Annually inspect the door closer and its mounting screws for any signs of loosening, wear, or damage.
  • Pulizia: Keep the door closer clean from dust and debris. Use a soft, damp panno per la pulizia. Evitare detergenti abrasivi o solventi.
  • Lubrificazione: No internal lubrication is required. Do not attempt to lubricate any part of the hydraulic mechanism.
  • Assemblaggio del braccio: Check the arm assembly for any bending or damage. Ensure all pivot points move freely without excessive play.

If any significant wear or damage is observed, contact a qualified technician for inspection and repair or replacement.

7. Risoluzione Dei Problemi

This section addresses common issues you might encounter with your CISA Serie 604 door closer.

ProblemaPossibile causaSoluzione
La porta sbatteClosing speed or final latching speed is too fast.Adjust Valve 1 (closing speed) and/or Valve 2 (final latching) clockwise in small increments until desired speed is achieved.
La porta si chiude troppo lentamenteClosing speed is too slow.Adjust Valve 1 (closing speed) counter-clockwise in small increments.
Door does not latch properlyFinal latching speed is too slow or insufficient.Adjust Valve 2 (final latching) counter-clockwise in small increments to increase latching force/speed.
Perdita di olioGuarnizioni o componenti interni danneggiati.This indicates a serious issue. The unit cannot be repaired by the user. Contact a qualified technician or replace the unit.
Door closer makes unusual noisesLoose mounting screws or damaged internal components.Check and tighten all mounting screws. If noise persists, contact a qualified technician.

8. Specifiche

CaratteristicaDettaglio
Numero di modello60450.03.97
MarcaCISA
TipoRack and Pinion Door Closer
Adjustable Closing ForceNorma EN 2-4
massimo Peso della porta85 kg
Larghezza massima della porta1100 millimetri
Uso consigliatoResidential and Commercial Doors
Dimensioni (L x P x A)Dimensioni: 18 cm x 4 cm x 6 cm
Peso1.44 kg
MaterialeAluminum (Body), Steel (Arm)
FineGrigio alluminio
Tipo di installazioneMontaggio in superficie

9. Garanzia e supporto

For information regarding warranty coverage, please refer to the documentation provided at the time of purchase or contact your retailer. CISA products are manufactured to high-quality standards, and proper installation and maintenance ensure long-lasting performance.

For technical support, spare parts, or service inquiries, please contact CISA customer service or your authorized dealer. Ensure you have your product model number (60450.03.97) and purchase details available when contacting support.

Documenti correlati - 60450.03.97

Preview Sensore CISA Mito: Manuale di installazione e utilizzo
Guida completa per la serratura CISA Mito Sensor, che descrive in dettaglio installazione, funzionamento, manutenzione, sicurezza e risoluzione dei problemi. Include specifiche tecniche e accessori.
Preview Guida all'installazione del microinterruttore a pressione CISA - Modello 06A95060
Istruzioni di installazione ufficiali per il microinterruttore a pulsante CISA (modello 06A95060), un componente per dispositivi antipanico. Include le fasi di fissaggio alla staffa e di verifica del funzionamento.
Preview Guida all'installazione del microinterruttore touch CISA
Istruzioni ufficiali di installazione per il microinterruttore CISA Touch (art. 06A95050), che descrivono dettagliatamente lo smontaggio del supporto del braccio, il montaggio del microinterruttore e i controlli operativi.
Preview Guida all'Installazione CISA: Comandi Esterni per Maniglioni Antipanico (Art. 07A78.xx)
Istruzioni dettagliotagliate per l'installazione dei comandi esterni CISA per maniglioni antipanico, modello Art. 07A78.xx. Includi capacità, luntaggio e specifiche tecniche.
Preview Guida all'installazione delle coperture per serrature elettriche CISA
Foglio di istruzioni per le coperture degli incontri elettrici CISA (art. 06A98120.XX), che descrive le configurazioni di installazione e le procedure di montaggio per diverse tipologie di bordo porta. Include indicazioni sulla scelta delle piastre e delle viti appropriate.
Preview CISA 06A98910 Adattatore per dispositivi di accesso rapido Retrofit - Guida all'installazione
Questo documento fornisce le istruzioni di installazione per l'adattatore CISA 06A98910 per dispositivi di accesso rapido retrofit. ...