1. Prodotto finitoview
The Sygonix SY-RSL-R3 SY-3523486 is a recessed RSL switch designed for controlling electrical devices wirelessly. It offers a maximum switching power of 2000 W and operates with a maximum range of 70 meters in open field conditions. This device is suitable for integration into existing electrical installations.

Figura 1: Fronte view of the Sygonix SY-RSL-R3 SY-3523486 Recessed RSL Switch. This image shows the compact white housing with the Sygonix logo and two pre-attached wires.
Caratteristiche principali:
- Recessed installation for discreet integration.
- Maximum switching power of 2000 W.
- Wireless operation with a range of up to 70 meters (open field).
- Compact design (25 x 49 x 49 mm).
- Durable plastic material.
2. Istruzioni di sicurezza
Please read these safety instructions carefully before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Sicurezza elettrica: Installation and maintenance must only be performed by a qualified electrician. Ensure the main power supply is disconnected before any installation or wiring work.
- Uso previsto: This device is designed for controlling electrical loads up to 2000 W. Do not exceed the maximum load capacity.
- Ambiente: The device has an IP67 rating, indicating protection against dust and temporary immersion in water. However, avoid exposing it to extreme temperatures, direct sunlight, or corrosive environments.
- Bambini: Keep the device and packaging materials out of reach of children.
- Danno: Do not operate the device if it appears damaged. Contact support for assistance.
3. Configurazione e installazione
This section provides instructions for the proper installation and initial setup of your Sygonix RSL switch.
3.1 Cablaggio
- Scollegare l'alimentazione: Before beginning any wiring, ensure the main power supply to the circuit is turned off at the circuit breaker. Verify with a voltagetester.
- Identificare i fili: Identify the live (L), neutral (N), and load wires for the device you intend to control.
- Connetti ingresso: Connect the incoming live and neutral wires to the corresponding input terminals on the switch. Refer to the wiring diagram on the device or in Figure 2.
- Uscita di connessione: Connect the load wire (to the device) and the neutral wire to the output terminals of the switch.
- Connessioni sicure: Assicurarsi che tutti i collegamenti dei cavi siano sicuri e adeguatamente isolati.

Figura 2: Indietro view of the Sygonix SY-RSL-R3 SY-3523486 Recessed RSL Switch, showing the wiring terminals. The terminals are clearly labeled for input and output connections.
3.2 Recessed Installation
- After wiring, carefully place the switch into the recessed box or cavity.
- Ensure there is adequate space and no wires are pinched or damaged.
- Secure the switch in place if necessary, following local electrical codes.
- Ripristina alimentazione: Una volta completata l'installazione e verificati tutti i collegamenti, ripristinare l'alimentazione tramite l'interruttore automatico.
3.3 Pairing with RSL Remote Control (if applicable)
To operate the switch wirelessly, it must be paired with a compatible RSL remote control (sold separately). Refer to your RSL remote control's manual for specific pairing instructions. Generally, the process involves:
- Put the RSL switch into pairing mode (often by pressing a small button on the device or cycling power).
- Activate the pairing function on your RSL remote control.
- Confirm successful pairing (e.g., the connected light flashes).
4. Istruzioni per l'uso
Once installed and paired, the Sygonix RSL switch can be operated using a compatible RSL remote control.
- Funzione di accensione/spegnimento: Use the designated ON/OFF buttons on your RSL remote control to switch the connected device on or off.
- Allineare: The effective operating range is up to 70 meters in open field conditions. Obstacles such as walls, ceilings, and other electronic devices can reduce this range.
- Modalità operativa: The switch supports an On-off-on operational mode, allowing for simple toggling of connected devices.
5. Manutenzione
The Sygonix RSL switch requires minimal maintenance.
- Pulizia: Disconnect power before cleaning. Use a soft, dry cloth to wipe the surface of the device. Do not use abrasive cleaners or solvents.
- Ispezione: Periodically inspect the wiring and connections for any signs of wear or damage. If any damage is found, disconnect power immediately and consult a qualified electrician.
6. Risoluzione Dei Problemi
If you encounter issues with your Sygonix RSL switch, refer to the following common problems and solutions:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Device does not respond to remote control. |
|
|
| Il dispositivo connesso non si accende/spegne. |
|
|
7. Specifiche tecniche
| Caratteristica | Specificazione |
|---|---|
| Numero di modello | Codice articolo: SY-3523486 |
| Marca | Sygonix |
| Dimensioni del prodotto (LxWxH) | Dimensioni: 25 x 49 x 49 mm |
| Peso | 40 grammi |
| Potenza di commutazione massima | 2000 L |
| Portata massima | 70 m (campo aperto) |
| Materiale | Plastica |
| Modalità operativa | Acceso-spento-acceso |
| Valutazione internazionale di protezione | Grado di protezione IP67 |
8. Garanzia e supporto
Sygonix products are manufactured with quality and reliability in mind. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Sygonix websito.
For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact Sygonix customer service or visit the Sygonix Brand Store.