Crown DP-60F

Crown DP-60F Direct Steam Stationary Kettle User Manual

Modello: DP-60F

1. Introduzione

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Crown DP-60F Direct Steam Stationary Kettle. Please read this manual thoroughly before operating the equipment to ensure proper usage and to prevent injury or damage.

The Crown DP-60F is a robust 60-gallon capacity stationary kettle designed for commercial food service applications. It features direct steam heating, a full jacket for even heat distribution, a 2-inch draw-off valve, and a durable 316 stainless steel interior liner. The unit is mounted on a pedestal base and includes a perforated strainer, a spring-assisted hinged cover, and a faucet cover for convenience and hygiene. It operates at 35 psi and is NSF certified.

2. Istruzioni di sicurezza

Always adhere to the following safety precautions to prevent personal injury or damage to the equipment.

3. Configurazione e installazione

Installation of the Crown DP-60F kettle should only be performed by certified professionals in accordance with local codes and regulations.

3.1 Disimballaggio

Carefully remove the kettle from its packaging. Inspect for any shipping damage. Report any damage to the carrier immediately.

3.2 Requisiti di posizione

Place the kettle on a level, stable surface capable of supporting its weight when full. Ensure adequate clearance for operation, cleaning, and maintenance. Provide proper ventilation.

3.3 Steam and Condensate Connections

Connect the kettle to a direct steam supply line with a maximum pressure of 35 psi. Install appropriate steam traps and condensate return lines as per manufacturer guidelines and local plumbing codes.

3.4 Electrical Connections (if applicable)

While primarily steam-operated, ensure any auxiliary electrical components (e.g., controls, indicators) are connected to a grounded power source as specified on the unit's data plate.

Crown DP-60F Direct Steam Stationary Kettle

Figure 1: Crown DP-60F Direct Steam Stationary Kettle. This image shows the stainless steel kettle with its pedestal base, hinged cover, and draw-off valve. The kettle has a smooth, polished finish.

4. Istruzioni per l'uso

4.1 Lista di controllo pre-operatoria

4.2 Riempimento del bollitore

Add desired ingredients to the kettle. Do not overfill; leave adequate headspace to prevent boil-overs.

4.3 Funzionamento a vapore

  1. Slowly open the main steam supply valve to the kettle.
  2. Monitor the pressure gauge to ensure it does not exceed 35 psi.
  3. Allow the kettle to heat to the desired temperature. The full jacket design ensures even heating.
  4. Adjust the steam supply valve as needed to maintain temperature.

4.4 Draining the Kettle

Once cooking is complete, close the steam supply valve. Carefully open the 2-inch draw-off valve to dispense contents. Use caution as contents will be hot.

4.5 Post-operatorio

After draining, close the draw-off valve. Allow the kettle to cool before cleaning.

5. Manutenzione e pulizia

Regular cleaning and maintenance are crucial for the longevity and hygienic operation of your Crown DP-60F kettle.

5.1 Pulizia giornaliera

5.2 Manutenzione periodica

Istruzioni per la cura del prodotto: Hand wash, Wipe clean.

6. Risoluzione Dei Problemi

This section provides solutions to common issues. For problems not listed, contact a qualified service technician.

ProblemaPossibile causaSoluzione
Kettle not heating or heating slowlyInsufficient steam pressure; Clogged steam trap; Steam supply valve closedVerify steam supply pressure; Inspect and clean steam trap; Open steam supply valve fully
Steam leaking from connectionsLoose fittings; Worn gasketsTighten fittings; Replace worn gaskets
Draw-off valve leakingWorn seal; ObstructionInspect and replace seal; Clear any obstruction

7. Specifiche

CaratteristicaDettaglio
Numero di modelloDP-60F
Capacità60 galloni
Tipo di riscaldamentoDirect Steam, Full Jacket
Materiale internoAcciaio inossidabile 316
Materiale esternoAcciaio inossidabile
Draw-off Valve Size2 pollici
Pressione massima di esercizio35 psi
CertificazioniNon vincolante
Tipo di basePiedistallo
Accessori inclusiPerforated strainer, Spring-assisted hinged cover, Faucet cover

8. Garanzia e supporto

For specific warranty information regarding your Crown DP-60F kettle, please refer to the warranty card included with your purchase or contact Crown customer service directly. Warranty terms typically cover manufacturing defects under normal use.

For technical support, parts, or service inquiries, please contact Crown customer service. Ensure you have your model number (DP-60F) and serial number ready when contacting support.

Produttore: Corona

Data prima disponibilità: 24 aprile 2019

Documenti correlati - DP-60F

Preview Manuale di installazione e funzionamento dei bollitori Crown Direct Steam Power inclinabili o fissi
Manuale di installazione e funzionamento per i bollitori Crown Direct Steam Power, inclinabili o fissi (serie DMT/DMS). ...
Preview Manuale di installazione e funzionamento dei bollitori fissi Crown Direct Steam (DL-80F, DL-125, DL-150, DP-80F)
Manuale ufficiale di installazione e funzionamento per i bollitori fissi Crown Direct Steam, modelli DL-80F, DL-125, DL-150 e DP-80F. Include precauzioni di sicurezza, collegamenti di servizio, dimensioni, specifiche, istruzioni per l'uso, procedure di pulizia, linee guida per la manutenzione e suggerimenti per la risoluzione dei problemi.
Preview Manuale di installazione e funzionamento del fornello a convezione Crown Electric Cabinet Base con bollitore/i a vapore diretto
Questo manuale fornisce una guida completa all'installazione, al funzionamento, alla pulizia, alla manutenzione e alla risoluzione dei problemi per i forni a vapore a convezione Crown Electric Cabinet Base con bollitore/i a vapore diretto, inclusi i modelli ECX-2-(6, 10), ECX-2-6-6, ECX-10-(6, 10) ed ECX-10-6-6.
Preview Manuale di installazione e funzionamento dei bollitori a vapore inclinabili a gas della serie Crown GLT
Manuale di installazione, funzionamento e manutenzione per i bollitori a gas a vapore inclinabili Crown GLT-20, GLT-30, GLT-40 e GLT-60. ...
Preview Manuale di installazione e funzionamento dei vaporizzatori a convezione Crown SCX-16 e SCX-24 con base a serpentina a vapore
Manuale completo di installazione e funzionamento per i forni a vapore a convezione Crown SCX-16 e SCX-24 con base a serpentina. Fornisce informazioni dettagliate su sicurezza, procedure di installazione, linee guida operative, manutenzione periodica, pulizia, regolazioni e risoluzione dei problemi per gli ambienti di cucina commerciale.
Preview Carrello elevatore retrattile per corsie strette Crown RD 5700 Series: specifiche e informazioni tecniche
Specifiche dettagliate, caratteristiche e informazioni tecniche per il carrello elevatore retrattile per corsie strette Crown serie RD 5700, tra cui dimensioni, dati sulle prestazioni, dettagli sul vano operatore e caratteristiche di sicurezza.