Elitetech RC-4HC

Manuale di istruzioni del registratore dati di temperatura e umidità USB Elitech RC-4HC

Model: RC-4HC

1. Prodotto finitoview

The Elitech RC-4HC is a USB temperature and humidity data logger designed for monitoring and recording environmental conditions. It features an internal temperature and humidity sensor, with an option for an external temperature sensor. The device has a large storage capacity and allows for data export via USB.

Elitech RC-4HC USB Temperature and Humidity Data Logger with packaging

Image 1: Elitech RC-4HC USB Temperature and Humidity Data Logger with its packaging, showing the device and the '50 PACK' label.

2. Contenuto della confezione

Assicurarsi che tutti gli articoli siano presenti nel pacco:

  • 1 x RC-4HC Data Logger
  • 1 x sensore di temperatura esterno
  • 1 cavo USB
  • 1 x Manuale utente
  • 1 x Validation Certificate
  • 1 x Lithium Metal Battery
Elitech RC-4HC package contents

Image 2: Contents of the Elitech RC-4HC package, including the data logger, external sensor, USB cable, user manual, certificate, and battery.

3. Configurazione e installazione

3.1 Installazione della batteria

Before initial use, install the included Lithium Metal battery.

  1. Individuare il vano batteria sul retro del data logger.
  2. Use a coin or similar tool to twist the battery cover counter-clockwise to open.
  3. Place the battery under the small metal clip with the positive pole (+) facing you.
  4. Richiudere il coperchio della batteria e ruotarlo in senso orario per fissarlo.
Steps for battery installation in Elitech RC-4HC

Image 3: A four-step visual guide demonstrating how to correctly install the battery into the Elitech RC-4HC data logger, showing the positive terminal placement.

3.2 External Sensor Connection (Optional)

If external temperature monitoring is required, connect the external temperature sensor to the designated port on the data logger.

Elitech RC-4HC connected to USB and external sensor

Image 4: The Elitech RC-4HC data logger connected to a computer via USB and also showing the external temperature sensor connected.

3.3 Software Installation and Initial Parameter Setup

To configure the data logger and retrieve data, install the ElitechLog software on your computer (compatible with MAC/WIN). The software allows you to set logging parameters such as interval (e.g., 10 seconds), alarm limits, and temperature units (e.g., ℃ or ℉).

ElitechLog software workflow for data logger setup

Image 5: A flowchart illustrating the workflow for setting up the data logger using ElitechLog software on both Windows and Mac operating systems, from connecting the device to saving parameters and starting recording.

Video: Elitech RC-4HC USB Temperature and Humidity Data Logger How to Use

4. Istruzioni per l'uso

4.1 Avvio della registrazione dei dati

After setting parameters via the software, disconnect the logger from the computer. To start logging, press and hold the button on the logger for more than 4 seconds. A triangle sign firmly lit up on the screen indicates that logging has started.

4.2 Viewing Current Data

Press the button once to light up the screen and view the current temperature. Press again to cycle through humidity, total logged points, time, date, maximum temperature, minimum temperature, and upper/lower temperature limits.

4.3 Data Retrieval and Export

Connect the data logger to your computer using the USB cable. Open the ElitechLog software. The software will automatically read the recorded data. You can then view the data in graph or list format and export it to PDF or Excel files. The software also supports managing and comparing multiple historical data sets.

Elitech RC-4HC data export via software

Image 6: An illustration showing the Elitech RC-4HC data logger connected to a computer, with data being exported to various formats like PDF, Word, Excel, and TXT via ElitechLog software.

5. Caratteristiche e specifiche

  • Sensori: Internal 1 temperature sensor and 1 humidity sensor, 1 optional external temperature sensor.
  • Intervallo di temperatura: -40℃ to +85℃ (-22℉ to 185℉).
  • Gamma di umidità: Dal 10% al 99% di umidità relativa.
  • Precisione della temperatura: ±0.5℃/±0.9℉ (-20℃ to +40℃); ±1℃/±1.8℉ (others).
  • Risoluzione: 0.1℃/℉.
  • Punti dati: 16,000.
  • Intervallo registro: Regolabile da 10 secondi a 24 ore.
  • Unità di temperatura: Selectable between ℉ and ℃.
  • Allarme: LCD alarm indication, buzzer alarm.
  • Connettività: USB for PC connection.
  • Esportazione dati: PDF/EXCEL via data management software.
  • Batteria: 1 Lithium Metal battery (included).
  • Dimensioni: Width: 44mm, Height: 84mm, Thickness: 20mm.
Elitech RC-4HC specifications

Image 7: A visual representation of the Elitech RC-4HC data logger's key specifications, including temperature and humidity measurement ranges, accuracy, resolution, and data capacity.

Elitech RC-4HC dimensions and buzzer alarm

Image 8: The Elitech RC-4HC data logger showing its dimensions (width 44mm, height 84mm, thickness 20mm) and highlighting the buzzer alarm feature.

6. Manutenzione

To ensure optimal performance and longevity of your Elitech RC-4HC data logger:

  • Pulizia: Pulisci il dispositivo con un panno morbido e asciutto. Evita di utilizzare detergenti abrasivi o solventi.
  • Sostituzione della batteria: Replace the Lithium Metal battery when the low battery indicator appears on the display.
  • Magazzinaggio: Quando non viene utilizzato per lunghi periodi, conservare il dispositivo in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.

7. Risoluzione Dei Problemi

If you encounter issues with your Elitech RC-4HC data logger, consider the following:

  • Dispositivo non avviato: Ensure the battery is correctly installed with the positive pole facing up and is not depleted.
  • No Data on Software: Verify the USB connection to the computer. Ensure the ElitechLog software is running and the device is recognized.
  • Letture errate: Check if the external sensor is properly connected (if used). Ensure the device is placed in an environment suitable for its operating range.
  • Problemi software: Ensure you have the latest version of ElitechLog software installed. Refer to the software's help documentation for specific error messages.

8. Garanzia e supporto

For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. using the details below:

Documenti correlati - RC-4HC

Preview Guida rapida all'avvio del data logger Elitech RC-4/RC-4HA/RC-4HC | Installazione e configurazione
Guida rapida per i data logger Elitech RC-4, RC-4HA e RC-4HC. Scopri come installare le batterie, configurare il software, configurare le impostazioni, avviare/interrompere la registrazione e risolvere i problemi più comuni. Include specifiche tecniche dettagliate per il monitoraggio di temperatura e umidità.
Preview Guida rapida all'avvio del data logger Elitech RC-4/RC-4HA/RC-4HC
Una guida rapida e concisa per i data logger Elitech RC-4, RC-4HA e RC-4HC, che fornisce istruzioni essenziali sull'installazione della batteria, la configurazione del software, il funzionamento del data logger, la configurazione e la risoluzione dei problemi.
Preview Manuale utente Elitech RC-4 / RC-4HC
Manuale utente per i data logger di temperatura e umidità Elitech RC-4 e RC-4HC. Include specifiche, funzionamento, indicazione di stato e sostituzione della batteria.
Preview Registratore dati di temperatura e umidità serie Elitech RC-4 - Manuale utente e specifiche
Manuale utente completo e specifiche tecniche per i data logger di temperatura e umidità Elitech serie RC-4 e RC-4HC. Scopri di più su funzionamento, configurazione, registrazione dei dati e funzionalità per la gestione della catena del freddo.
Preview Registratori di dati di temperatura e umidità serie Elitech RC-4 - Manuale utente
Manuale utente completo per i data logger di temperatura e umidità Elitech serie RC-4 e RC-4HC. Include specifiche, funzionamento, configurazione e risoluzione dei problemi per il monitoraggio della catena del freddo.
Preview Manuale utente del data logger di temperatura e umidità Elitech RC-4/RC-4HC
Questo manuale utente fornisce istruzioni complete per il funzionamento e la manutenzione dei data logger di temperatura e umidità Elitech RC-4 e RC-4HC. Copre le caratteristiche del prodotto, il funzionamento, la configurazione dei parametri, i dati viewing ed esportazione, sostituzione della batteria, specifiche, precauzioni e informazioni sulla garanzia.