SECUKEY SF2

SECUKEY SF2 Biometric and PIN Access Control System User Manual

Modello: SF2

1. Introduzione

Thank you for choosing the SECUKEY SF2 Biometric and PIN Access Control System. This device is designed to provide secure and reliable access management for various environments, featuring advanced biometric fingerprint recognition and PIN code entry. Its robust, anti-vandal design and IP66 rating make it suitable for outdoor installations. This manual provides essential information for the proper installation, configuration, operation, and maintenance of your SF2 system. Please read it thoroughly before use.

Caratteristiche principali

2. Informazioni sulla sicurezza

3. Prodotto finitoview

3.1 Front View

SECUKEY SF2 Biometric Access Control System Front View
Figura 1: Davanti view of the SECUKEY SF2 access control system, showing the numeric keypad, fingerprint sensor, and the 'Secukey' brand logo.

3.2 Indietro View e connessioni

SECUKEY SF2 Biometric Access Control System Back View con cablaggio
Figura 2: Indietro view of the SECUKEY SF2, illustrating the wiring cable exit point, model number (SF2), input voltage (12V DC), and CE certification mark.

3.3 Caratteristiche fisiche

4. Installazione

4.1 Montaggio

The SECUKEY SF2 should be mounted on a flat, stable surface at an appropriate height for user access. Ensure the mounting location is secure and allows for proper cable routing. Use appropriate screws and anchors for the wall material.

4.2 Cablaggio

The SF2 supports two primary working modes: standalone and as a slave reader. Proper wiring is crucial for correct operation. Refer to the detailed wiring diagram provided in the product packaging or the manufacturer's official documentation for specific connections.

SECUKEY SF2 Two Working Modes Wiring Diagram
Figura 5: Diagram illustrating the two working modes of the SECUKEY SF2: standalone operation (left) and slave reader operation integrated with a controller via Wiegand (right). This image also shows the operating temperature range and the higher security PIN input method.

Modalità autonoma: In this mode, the SF2 directly controls the lock, door sensor, and exit button. It acts as a complete access control unit.

Slave Reader Mode: When operating as a slave reader, the SF2 connects to an external access control panel (controller) via Wiegand 26-44 bit output. The controller then manages the lock and other peripherals.

Ensure all connections are secure and insulated. Incorrect wiring can damage the device or connected components.

5. Impostazione

5.1 Accensione iniziale

  1. After completing all wiring, connect the power supply (12-24V AC/DC).
  2. The device will power on and perform a self-test.
  3. The default administrator PIN is typically 123456 (refer to specific product documentation for confirmation).

5.2 Gestione utenti

The SF2 allows for the registration of up to 3,000 users, including 1,000 fingerprint users and 2,000 PIN users. It also supports two "Authorizer" users who can enable or disable other users.

Aggiungere un amministratore

Follow the on-screen prompts or refer to the detailed programming guide to set up the initial administrator PIN and/or fingerprint. This is crucial for managing other users and system settings.

Registrazione delle impronte digitali

  1. Enter administrator mode.
  2. Select the option to add a new fingerprint user.
  3. Place the user's finger on the sensor multiple times as instructed to ensure accurate registration.
  4. Assign a user ID to the registered fingerprint.

Registering PIN Codes

  1. Enter administrator mode.
  2. Select the option to add a new PIN user.
  3. Enter the desired PIN code (typically 4-6 digits) and confirm it.
  4. Assign a user ID to the registered PIN.

Authorizer Users

The SF2 supports two special "Authorizer" users. These users have the unique ability to enable or disable other standard users without full administrator privileges. This feature is useful for delegated management of user access.

6. Istruzioni per l'uso

6.1 Modalità di accesso

The SECUKEY SF2 offers multiple ways for authorized users to gain access:

6.2 Funzione di interblocco

When two SF2 devices are installed, they can be configured to manage an interlock system between two doors. This ensures that the second door cannot be opened until the first door is securely closed, enhancing security in sensitive areas. Refer to the advanced programming guide for interlock setup instructions.

7. Manutenzione

8. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Nessuna alimentazione o cablaggio errato.Check power connections and ensure the power supply is within 12-24V AC/DC. Verify wiring according to the diagram.
Impronta digitale non riconosciuta.Finger is dirty, wet, or improperly placed; fingerprint not registered; sensor is dirty.Ensure finger is clean and dry. Place the entire pad of the finger firmly on the sensor. Clean the sensor surface. Re-register the fingerprint if necessary.
Codice PIN non accettato.Incorrect PIN entered; PIN not registered.Verify the PIN code. Ensure the '#' key is pressed after entering the PIN. Register the PIN if it's a new user.
La porta non si sblocca dopo l'autenticazione riuscita.Lock wiring issue; relay setting incorrect; lock malfunction.Check wiring to the lock. Verify relay output time and mode (NO/NC). Test the lock independently.
Il dispositivo non risponde.System crash; power fluctuation.Disconnect power for 30 seconds, then reconnect. If the issue persists, contact technical support.

9. Specifiche

ParametroValore
Numero di modelloSF2
Biometric Reader TypeOttico
Risoluzione500DPI
Tempo di identificazione< 1 secondo
FAR (tasso di falsa accettazione)0.001%
FRR (tasso di falsi rifiuti)0.01%
Capacità dell'utente3,000 (1,000 Fingerprint, 2,000 PIN)
Authorizer Users2
Grado di protezioneIP66 (Outdoor, Anti-Vandal)
Uscita relè1 programmable (NO, NC, Common)
Tempo di uscita1 to 99 seconds (Default: 5 seconds)
Modalità di accessoFingerprint, PIN, Card (Wiegand)
Uscita Wiegand26-44 bit
Alimentazione elettrica12-24V AC / DC
Blocco del carico di uscita2 Amp massimo
Temperatura di esercizio-30°C to 60°C (-22°F to 140°F) (Optional -40°C)
Umidità di esercizioDa 10% RH a 99% RH
Casing MaterialeLega di zinco
ColoreArgento
DimensioniDimensioni: 13.7 x 5.8 x 2.6 cm
Peso400 grammi

10. Garanzia e supporto

For warranty information and technical support, please refer to the documentation included with your purchase or visit the official SECUKEY websito. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.

Information regarding spare parts availability and software updates is not explicitly provided in the product details. Please contact SECUKEY customer service for the most current information.