The PEDROLLO Presscontrol Easy Press II is an advanced electronic device designed to automate the operation of single-phase electric pumps up to 2 HP. It manages the pump's start and stop functions based on water demand, activating the pump when a tap is opened and deactivating it when the tap is closed.

Equipped with microprocessor logic, the Easy Press II offers crucial protection features. It safeguards the pump against dry running, automatically or manually resetting the system after a dry-run event. Furthermore, it prevents excessively frequent pump starts, which can occur due to minor leaks in the water system, thereby extending the pump's lifespan and ensuring stable water pressure.

PEDROLLO Presscontrol Easy Press II Electronic Pressure Regulator

Figura 1: Fronte view of the PEDROLLO Presscontrol Easy Press II.

This image shows the compact design of the Easy Press II, featuring a pressure gauge, status indicators (Power, Out of Service, Dry, Running, Frequent Start-up), and the Pedrollo branding. The device is primarily white and blue with orange accents.

2. Caratteristiche principali

  • Automatic Pump Control: Starts and stops single-phase electric pumps based on water demand.
  • Protezione contro il funzionamento a secco: Microprocessor logic prevents pump damage from operating without water, with automatic or manual reset.
  • Protezione dalle perdite: Protects the pump from frequent starts caused by small system leaks.
  • Manometro integrato: Allows for easy monitoring of system pressure.
  • Grado di protezione elevato: IP 65 rated for dust and water resistance, suitable for various environments.
  • Design robusto: Realizzato in materiale plastico resistente.

3. Specifiche

AttributoValore
ProduttorePEDROLLO
ModelloEasy Press II
Portata massima200 litri al minuto (12 m³/h)
Pressione di esercizio10 barre
Pressione di avvio1.5 barre
Liquid Temperature LimitFino a +65 °C
Ambient Temperature LimitFino a +40 °C
Pressione di scoppio> 40 bar
Grado di protezioneTipo di protezione IP65
Voltage230 Volt
FrequenzaFrequenza 50/60 Hz
Max corrente16 A (for Easy Press II)
Peso dell'articolo2 chilogrammi
ColoreArancia
MaterialePlastica
Fonte di alimentazioneCavo elettrico

4. Informazioni sulla sicurezza

Always read and understand all safety warnings and instructions before installing, operating, or maintaining the PEDROLLO Presscontrol Easy Press II. Failure to follow these instructions could result in electric shock, fire, serious injury, or property damage.

  • Ensure the power supply matches the device's specifications (230V, 50/60Hz).
  • Tutti i collegamenti elettrici devono essere eseguiti da un elettricista qualificato e conformi alle normative elettriche locali.
  • Scollegare l'alimentazione prima di eseguire qualsiasi installazione, manutenzione o risoluzione dei problemi.
  • Do not operate the device if it is damaged or if the power cable is frayed.
  • Tenere i bambini e il personale non autorizzato lontani dall'area di installazione.
  • Garantire una messa a terra adeguata per evitare rischi elettrici.

5. Installazione e configurazione

The Easy Press II is designed for easy integration into single-phase electric pump systems. Proper installation is crucial for optimal performance and safety.

  1. Montaggio: Install the Easy Press II vertically, ensuring the flow direction matches the arrows on the device. It should be mounted between the pump and the first point of water consumption.
  2. Collegamento idraulico: Connect the inlet of the Easy Press II to the pump's discharge and the outlet to the system's piping. Ensure all connections are watertight using appropriate sealants (e.g., PTFE tape).
  3. Collegamento elettrico:
    • Connect the power supply cable to the Easy Press II's input terminals.
    • Connect the pump's power cable to the Easy Press II's output terminals.
    • Ensure all connections are secure and properly insulated. Refer to the wiring diagram provided in the technical documentation (Figure 2).
  4. Preparazione del sistema: Before starting the pump, ensure the pump and the Easy Press II are fully primed with water to prevent dry running.
  5. Avvio iniziale: Once all connections are secure and the system is primed, restore power. The Easy Press II will initiate the pump when water demand is detected.
PEDROLLO Presscontrol Easy Press II Technical Diagram and Dimensions

Figure 2: Technical diagram and dimensions of the PEDROLLO Easy Press II.

This image provides detailed technical specifications, performance curves, and dimensional drawings for the Easy Press II. It illustrates various models (Easy Press 1, Easy Press 2) and their electrical characteristics, as well as typical installation setups and physical dimensions.

6. Funzionamento

The PEDROLLO Easy Press II operates automatically once installed and powered. It functions as an electronic flow and pressure switch.

  • Pump Start: When a tap or valve in the system is opened, causing a drop in pressure and flow, the Easy Press II detects this demand and automatically starts the connected electric pump.
  • Pump Stop: When all taps or valves are closed, and water flow ceases, the Easy Press II detects the absence of flow and stops the pump after a short delay, maintaining system pressure.
  • Indicatori di stato: The device features LED indicators (Power, Out of Service, Dry, Running, Frequent Start-up) to provide visual feedback on its operational status. Refer to the device's front panel for specific indicator meanings.

7. Manutenzione

The PEDROLLO Easy Press II is designed for minimal maintenance. However, regular checks can help ensure its longevity and reliable operation.

  • Ispezione regolare: Periodically check the device and its connections for any signs of leaks, damage, or corrosion.
  • Pulizia: Keep the exterior of the device clean and free from dust or debris. Do not use abrasive cleaners.
  • Preparazione per l'inverno (se applicabile): In areas subject to freezing temperatures, ensure the device and connected piping are drained or protected from frost to prevent damage.
  • Controllo del manometro: Monitor the pressure gauge regularly to ensure it is functioning correctly and providing accurate readings.

Always disconnect power to the device before performing any maintenance or inspection.

8. Risoluzione Dei Problemi

The Easy Press II incorporates intelligent features to protect the pump and indicate operational issues. Here are common scenarios and their resolutions:

  • Pump Not Starting / "Dry" Indicator On:
    • Causa: Dry running detected (no water in the pump or suction line).
    • Soluzione: Ensure the pump is primed with water. The Easy Press II may attempt an automatic reset after a period. If not, manually reset the device by pressing the "START/STOP" button or by cycling the power.
  • Pump Cycling Frequently / "Frequent Start-up" Indicator On:
    • Causa: Small leaks in the system (e.g., dripping tap, faulty toilet fill valve) or a non-return valve issue.
    • Soluzione: Inspect all plumbing fixtures and connections for leaks. Repair any leaks found. Check the non-return valve in the system for proper operation.
  • Pump Not Stopping:
    • Causa: Continuous water flow (e.g., open tap, major leak) or a sensor malfunction.
    • Soluzione: Close all taps and check for significant leaks. If the pump continues to run without demand, disconnect power and contact a qualified technician.
  • No Power / "Power" Indicator Off:
    • Causa: No electrical supply to the device.
    • Soluzione: Check the circuit breaker, fuses, and power connections. Ensure the power outlet is functional.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact a qualified technician or the manufacturer's support.

9. Garanzia e supporto

Information regarding the specific warranty period and terms for the PEDROLLO Presscontrol Easy Press II is typically provided at the point of purchase or within separate documentation accompanying the product. Please retain your proof of purchase for warranty claims.

For technical support, spare parts, or service inquiries, please contact your authorized PEDROLLO dealer or the manufacturer directly. Information on spare parts availability was not provided in the product details.

Manufacturer: PEDROLLO

Documenti correlati - Easy Press II

Preview Scheda tecnica del dispositivo di controllo automatico Pedrollo PRESFLO MULTI
Scheda tecnica del dispositivo elettronico Pedrollo PRESFLO MULTI per il controllo e la protezione di elettropompe monofase per uso domestico. Dettagli su caratteristiche, specifiche, installazione e regolazione per impianti di approvvigionamento idrico e irrigazione.
Preview Pedrollo EP Electronic Pump Protector: Guida all'installazione e al funzionamento
Guida completa al protettore elettronico per pompe Pedrollo EP, che descrive in dettaglio le sue funzioni per la marcia a secco, la sovracorrente e la tensionetage protezione, insieme alle istruzioni di installazione e funzionamento.
Preview Pedrollo PRESFLO MULTI Dispositivo di Controllo Automatico - Specifiche Tecniche
Specifiche tecniche dettagliate, guida all'installazione e caratteristiche del dispositivo automatico di controllo della pressione elettronico Pedrollo PRESFLO MULTI per l'approvvigionamento idrico domestico e l'aumento della pressione.
Preview Dispositivo di protezione elettronico Pedrollo EP - Manuale utente e scheda tecnica
Guida completa al dispositivo di protezione elettronica Pedrollo EP, che ne descrive in dettaglio le caratteristiche, le specifiche tecniche, l'installazione e il funzionamento. Protegge le pompe da funzionamento a secco, sovracorrente e sovratensione.tage, e sottovoltage. Adatto all'uso domestico.
Preview Quadro elettronico di controllo EVOLUTION per elettropompe - Manuale d'uso PEDROLLO
Manuale d'uso completo per il quadro di controllo elettronico PEDROLLO EVOLUTION, che descrive in dettaglio installazione, funzionamento, programmazione, specifiche tecniche e risoluzione dei problemi per elettropompe monofase e trifase.
Preview Quadri elettrici elettronici per pompe Pedrollo E1-E2
Guida completa ai quadri di controllo elettronici Pedrollo E1 ed E2, progettati per la gestione di sistemi a pompa singola o doppia in ambienti residenziali, commerciali e industriali. Le caratteristiche includono modalità di funzionamento selezionabili, protezione contro la marcia a secco e interfacce utente intuitive per un funzionamento efficiente della pompa.