1. Introduzione
This user manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope. This advanced instrument is designed for precise signal analysis, offering high resolution and versatile measurement capabilities for various applications, including embedded systems, power electronics, and automotive electronics.

Figura 1: Fronte view of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope, showcasing its large touchscreen display, multiple input channels, and control knobs. The device features a blue handle for portability.
2. Installazione e configurazione iniziale
2.1 Disimballaggio e ispezione
Carefully remove the oscilloscope from its packaging. Inspect the unit for any signs of physical damage that may have occurred during transit. Retain the original packaging for future transportation or storage.
2.2 Collegamento di alimentazione
- Assicurarsi che l'interruttore di alimentazione dell'oscilloscopio sia in posizione OFF.
- Collegare il cavo di alimentazione in dotazione all'ingresso CA sul pannello posteriore dell'oscilloscopio.
- Collegare l'altra estremità del cavo di alimentazione a una presa di corrente CA dotata di messa a terra.
2.3 Accensione iniziale
Press the power button located on the front panel. The oscilloscope will perform a self-test and boot up. The display will show the Tektronix logo followed by the main measurement interface.
2.4 Connecting Probes and Inputs
The MSO44 features FlexChannels, which can be configured as analog or digital inputs.
- For analog signals, connect BNC probes to the input connectors on the front panel.
- For digital signals, use the appropriate digital probe accessories (sold separately) and connect them to the dedicated digital input ports.
- Ensure all connections are secure to prevent signal degradation.
3. Istruzioni per l'uso
3.1 Interfaccia utente terminataview
The oscilloscope features a 13.3-inch HD capacitive touchscreen display for intuitive operation. Key controls are also available via physical knobs and buttons on the right side of the display.
3.2 Misurazioni di base
- Configurazione del canale: Press the channel button corresponding to the input you wish to configure. Use the touchscreen or vertical scale knob to adjust vertical sensitivity (Volts/Div).
- Base temporale: Use the horizontal scale knob to adjust the time base (Seconds/Div) to view il numero di cicli desiderato.
- Attivazione: The trigger system stabilizes repetitive waveforms. Use the trigger level knob to set the trigger threshold. Select trigger type (Edge, Pulse, Runt, etc.) from the trigger menu on the screen.
- Misure: Access the 'Measure' menu to add automatic measurements such as frequency, peak-to-peak voltage, RMS, ecc.
3.3 Funzionalità avanzate
- FlexChannel Technology: Each FlexChannel input can be configured as one analog channel or eight digital logic channels. This is configured through the channel setup menu.
- Modalità ad alta risoluzione: The oscilloscope offers 12-bit ADC resolution, which can be enhanced to 16 bits in High Resolution Mode for more precise measurements. Enable this mode via the display settings.
- Lunghezza del record: The MSO44 features a 31.25 M record length, allowing for capture of long signal durations at high sample rates. Adjust record length settings in the acquisition menu.
- Strumenti di analisi: Utilize built-in analysis tools such as FFT (Fast Fourier Transform) for frequency domain analysis, cursors for precise point measurements, and waveform math functions.
4. Manutenzione
4.1 Pulizia dello strumento
Per mantenere le prestazioni e l'aspetto del tuo oscilloscopio:
- Esterno: Utilizzare un morbido, damp cloth with a mild detergent to clean the exterior surfaces. Avoid abrasive cleaners or solvents.
- Display: Use a soft, lint-free cloth specifically designed for cleaning electronic displays. Do not spray cleaning solutions directly onto the screen.
- Connettori: Keep input connectors clean and free of dust. Use compressed air if necessary, but avoid inserting objects into the connectors.
4.2 Calibrazione
The MSO44 is factory calibrated. For optimal performance, periodic calibration by a qualified service center is recommended. Refer to the Tektronix website or contact support for calibration services.
4.3 Conservazione
When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a suitable protective case.
5. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun display dopo l'accensione | Cavo di alimentazione non collegato; problema con la presa di corrente; guasto interno | Check power cord connection; Verify power outlet functionality; Contact Tektronix support |
| Nessuna forma d'onda visualizzata | Probe not connected; Incorrect channel settings; Trigger not set correctly; Signal too small or large | Ensure probe is connected and functional; Check channel voltage/division settings; Adjust trigger level and type; Adjust vertical scale or input signal |
| Forma d'onda instabile | Improper trigger settings; Noise in signal; Grounding issue | Adjust trigger source, level, and slope; Use averaging or bandwidth limit; Ensure proper grounding of the oscilloscope and circuit |
| Il touchscreen non risponde | Problema software temporaneo; necessaria la calibrazione dello schermo | Restart the oscilloscope; Refer to the full manual for touchscreen calibration procedures |
6. Specifiche
The following table outlines the key technical specifications for the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope.
| Caratteristica | Specificazione |
|---|---|
| Number of FlexChannels | 4 |
| Bandwidth (all analog channels) | 200 MHz |
| Sample Rate (all analog/digital channels) | 6.25 GS/s (real-time) |
| Risoluzione verticale | 12 bits ADC (16 bits in High Resolution Mode) |
| Display | 13.3 in. color HD (1920 x 1080) capacitive touchscreen |
| Lunghezza del record | 31.25 milioni di punti |
| Dimensioni del prodotto | 2.76 x 0.79 x 10.24 pollici |
| Peso dell'articolo | 48.75 libbre |
7. Garanzia e supporto
7.1 Informazioni sulla garanzia
Tektronix products are backed by a standard warranty. For detailed information regarding the warranty period and terms for your MSO44 4-BW-200 oscilloscope, please refer to the warranty card included with your product or visit the official Tektronix websito.
7.2 Supporto tecnico
Should you encounter any issues or require technical assistance, please contact Tektronix customer support.
- Risorse online: Visit the official Tektronix support website for FAQs, drivers, software updates, and additional documentation.
- Informazioni sui contatti: Refer to the Tektronix websito per i numeri di contatto regionali e il supporto via e-mail.
- When contacting support, please have your product model number (MSO44 4-BW-200) and serial number ready.