This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Prity FGW15 wood-burning stove with oven and back boiler. This appliance is designed to provide both room heating and hot water for central heating systems, while also offering a functional oven for cooking. Please read this manual thoroughly before using the appliance and retain it for future reference.

The Prity FGW15 stove complies with European standards EN 13240:2001 and EN 13299:2001, ensuring its quality and safety for domestic use.

2. Informazioni sulla sicurezza

Installazione professionale richiesta: This appliance requires professional installation by a qualified technician to ensure safe and correct operation, as well as compliance with local building codes and regulations. Improper installation can lead to fire hazards, carbon monoxide poisoning, and other serious risks.

2.1 Avvertenze generali di sicurezza

2.2 Minimum Clearances to Combustible Materials

Per prevenire rischi di incendio, mantenere le seguenti distanze minime dai materiali combustibili:

These distances are critical for safety. Consult your installer for specific requirements based on your installation.

2.3 Permissible Fuel

Utilizzare solo dry firewood as fuel. The wood moisture content should be 16 ± 4% according to EN 13240:2006, EN 13229:2006, EN 12815:2006 Annex B, Table B.1. Do not burn treated wood, plastics, coal, or any other materials not specified for wood-burning stoves, as this can damage the appliance, create hazardous emissions, and void your warranty.

3. Componenti del prodotto

The Prity FGW15 is a versatile appliance combining a wood-burning firebox, an oven, and a back boiler for central heating. Key components include:

Davanti view of Prity FGW15 wood-burning stove with oven and back boiler, showing the firebox, oven, and ash drawer.

Figura 3.1: Fronte view of the Prity FGW15 stove, highlighting the firebox, oven, and ash drawer.

Posteriore view of Prity FGW15 wood-burning stove, showing the back boiler connections and flue outlet.

Figura 3.2: Posteriore view of the Prity FGW15 stove, illustrating the cold and hot water connections for the back boiler and the flue pipe outlet.

4. Specifiche tecniche

Below are the detailed technical specifications for the Prity FGW15 wood-burning stove:

Prity FGW15 wood-burning stove dimensions: 93 cm height, 57 cm width, 53 cm depth.

Figure 4.1: Key dimensions of the Prity FGW15 stove.

CaratteristicaSpecificazione
ModelloFGW15
Marcaprity
Dimensioni del prodotto (P x L x A)Dimensioni: 53 x 57 x 93 cm
Peso136 kg
MaterialeGhisa
Nominal Room Heating Power5 kW
Nominal Water Heating Power15 kW
Total Nominal Heat Output19.8 kW
Capacità della caldaia15 litri
Cold Water Inlet / Hot Water Outlet2.5 cm (1 pollici)
Diametro del tubo di scarico130 millimetri
Efficienza76.5%
Approximate Heating Surface Area114 m² (for room heating)
Firebox Dimensions (W x D x H)Dimensioni: 465 x 240 x 430 mm
Oven Dimensions (W x D x H)Dimensioni: 380 x 400 x 200 mm
Pressione massima di esercizio (acqua)1.25 barre
Temperatura dei gas di combustione192 °C
CO in Flue Gas1031.3 mg/Nm³ (0.0985 %)
Dust Content26.4mg/Nm³
NOx Content102.7mg/Nm³
CxHy Content43.8mg/Nm³

5. Requisiti di installazione

Installation of the Prity FGW15 stove must be carried out by a certified professional in accordance with all national and local building and fire safety regulations. This includes proper chimney connection, flue pipe installation, and integration with your central heating system.

5.1 Chimney and Flue Pipe

5.2 Water Connections for Back Boiler

The back boiler requires connection to a closed or open central heating system. The cold water inlet and hot water outlet connections are 2.5 cm (1 inch). A qualified plumber must perform these connections, ensuring proper pressure relief valves, expansion tanks, and circulation pumps are installed according to system requirements and local codes.

5.3 Positioning and Clearances

Refer to Section 2.2 for minimum clearances to combustible materials. The stove must be placed on a non-combustible hearth extending beyond the appliance as required by local regulations.

6. Istruzioni per l'uso

Before operating, ensure all installation checks are complete and the central heating system (if connected) is filled and vented.

6.1 Starting the Fire

  1. Aprire entrambe le prese d'aria anterioriamper e il fumo dampcompletamente.
  2. Place a small amount of kindling and firelighters on the cast iron grate in the firebox.
  3. Light the kindling. Once it is burning well, add small pieces of dry firewood.
  4. Close the firebox door securely.
  5. Allow the fire to establish fully before adding larger logs.

6.2 Air Control and Flame Intensity

La stufa è dotata di due comandi manualiamppersone:

Regola entrambi i dampers to achieve a steady, efficient burn. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or poor draft.

6.3 Utilizzo del forno

The oven utilizes heat from the firebox below. The oven temperature will vary depending on the intensity of the fire. Monitor the oven temperature gauge and adjust the fire's intensity as needed for cooking. Preheat the oven thoroughly before placing food inside.

7. Manutenzione

Regular maintenance is crucial for the safe and efficient operation of your Prity FGW15 stove.

7.1 Rimozione della cenere

Remove ash from the ash drawer regularly, ideally before each use or when the ash bed becomes thick. Allow the stove to cool completely before removing ash. Dispose of ash in a metal container with a tight-fitting lid, away from combustible materials.

7.2 Pulizia del vetro

Clean the ceramic glass on the firebox and oven doors as needed. Use a specialized stove glass cleaner or a damp cloth dipped in fine ash (when cold) to remove soot. Avoid abrasive cleaners or tools that could scratch the glass.

7.3 Pulizia del condotto fumario e del camino

The flue pipe and chimney must be inspected and cleaned by a qualified chimney sweep at least once a year, or more frequently if heavy use or creosote buildup is observed. Blockages can lead to dangerous chimney fires and carbon monoxide accumulation.

7.4 Ispezione generale

Periodically check all seals, hinges, and dampers for wear or damage. Ensure water connections for the back boiler are free from leaks. Replace any worn parts promptly.

8. Risoluzione Dei Problemi

This section addresses common issues you might encounter with your Prity FGW15 stove.

ProblemaPossibile causaSoluzione
Fumo che entra nella stanzaBlocked chimney/flue, insufficient draft, door opened too quickly, wet fuel.Check chimney/flue for blockages. Ensure dampers are open. Use dry fuel. Open door slowly.
Bassa emissione di caloreInsufficient air supply, wet fuel, small fire, poor insulation.All'aria aperta dampers. Use dry, seasoned wood. Build a larger fire. Check room insulation.
Il fuoco brucia troppo velocementeExcessive air supply, door not sealed properly.Chiudere l'aria dampers partially. Check door seals and replace if necessary.
Il vetro si annerisce rapidamenteWet fuel, insufficient air for combustion, low burning temperature.Use dry fuel. Increase air supply. Ensure fire burns hot enough.
Central heating not heating effectivelyLow fire intensity, air in system, pump malfunction, system blockage.Increase fire intensity. Bleed radiators. Check circulation pump. Consult a plumber.

If you encounter persistent problems that cannot be resolved using this guide, contact a qualified technician or your seller for assistance.

9. Conformità e certificazioni

The Prity FGW15 wood-burning stove is manufactured and tested to meet stringent European standards.

9.1 European Standards

This appliance complies with:

9.2 Energy Efficiency Label

The Prity FGW15 has an energy efficiency rating of A. This label provides information on the energy performance of the appliance.

Energy efficiency label for Prity FGW15 stove, showing an A rating and heat outputs.

Figure 9.1: Energy Efficiency Label for Prity FGW15.

9.3 Dichiarazione di prestazione

A Declaration of Performance (DoP) is available, confirming the essential characteristics and performance of the product in accordance with Regulation (EU) No 305/2011.

Declaration of Performance document for Prity FGW15, detailing compliance and technical data.

Figure 9.2: English Declaration of Performance for Prity FGW15.

10. Garanzia e supporto

For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your seller directly. In case of technical issues, questions, or the need for spare parts, please contact the retailer from whom you purchased the Prity FGW15 stove. Ensure you have your purchase details and the product model number (FGW15) available when contacting support.

Documenti correlati - FGW15

Preview Prity Fireplaces and Fireboxes: Installation and Operation Manual
Comprehensive guide for Prity fireplaces and fireboxes, covering technical specifications, installation procedures, operation instructions, maintenance, and warranty information. Ensure safe and efficient use of your Prity heating appliance.
Preview Caldaie Prity: descrizione tecnica, manuale di installazione e funzionamento
Guida completa per le caldaie residenziali Prity, che comprende specifiche tecniche, procedure di installazione, istruzioni per l'uso, manutenzione e risoluzione dei problemi per i modelli a combustibile solido e a pellet.