1. Introduzione
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the ABB ACS580-01-026A-4 Drive. This industrial drive is designed for various applications requiring precise motor control, offering a robust solution for 400V systems with an 11KW power rating and 25A current capacity, housed in an IP21 rated frame size R2.
Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and to prevent damage to the equipment or injury to personnel.
2. Informazioni sulla sicurezza
AVVERTIMENTO: Electrical shock hazard. Only qualified personnel should perform installation, commissioning, and maintenance of this equipment. Disconnect all power before servicing.
- Ensure proper grounding of the drive and motor.
- Non utilizzare l'unità con cavi o componenti danneggiati.
- Rispettare sempre le normative elettriche locali e nazionali.
- Proteggere l'unità da umidità, polvere e temperature estreme.
3. Configurazione e installazione
The ABB ACS580-01-026A-4 Drive is designed for DIN Rail mounting. Ensure adequate ventilation around the unit.
3.1. Montaggio
Mount the drive vertically on a DIN rail in an enclosure that provides the specified IP21 protection. Allow sufficient clearance for cooling air flow above and below the unit.

Figura 3.1: Fronte view of the ABB ACS580-01-026A-4 Drive, showing its compact design and control panel area. This image illustrates the overall physical appearance of the drive unit.
3.2. Cablaggio
Connect the main power supply (400V AC) to the designated input terminals. Connect the motor to the output terminals. Ensure all connections are secure and correctly phased. Refer to the wiring diagram provided with the drive for detailed terminal assignments.
- Potenza in ingresso: L1, L2, L3 (400V AC)
- Uscita motore: U, V, W
- Messa a terra: Connect to protective earth (PE) terminal.
- Cablaggio di controllo: Connect control signals (e.g., start/stop, speed reference) as per application requirements.
4. Istruzioni per l'uso
Once installed and wired, the drive can be configured and operated. The ACS580 series features an intuitive control panel for parameter setting and monitoring.
4.1. Accensione iniziale
- Verificare che tutti i collegamenti elettrici siano corretti e sicuri.
- Apply main power to the drive. The control panel should illuminate.
- Follow the quick setup wizard on the control panel to configure basic motor parameters (e.g., motor nominal voltage, current, frequency, speed).
4.2. Funzionamento di base
- Avvio/Arresto: Use the designated control input (e.g., digital input) or the control panel buttons to start and stop the motor.
- Controllo della velocità: Adjust the motor speed using the analog input, fieldbus, or control panel potentiometer, depending on configuration.
- Monitoraggio: The control panel displays operational data such as motor speed, current, voltage, e codici di errore.
5. Manutenzione
Regular maintenance ensures the longevity and reliable operation of the ABB ACS580-01-026A-4 Drive.
- Pulizia: Periodically clean the drive's exterior and cooling fins to prevent dust accumulation, which can impede heat dissipation. Use a soft, dry cloth.
- Controllo della ventola: Inspect the cooling fan for proper operation and cleanliness. Replace if noisy or not functioning correctly.
- Verifica della connessione: Annually, or as needed, verify that all electrical connections are tight and free from corrosion.
- Condizioni ambientali: Assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.
6. Risoluzione Dei Problemi
This section provides guidance for common issues encountered during the operation of the drive.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'unità non si accende | No input power; Blown fuse; Incorrect wiring | Check main power supply; Inspect fuses; Verify wiring connections. |
| Il motore non si avvia | Control signal missing; Parameter misconfiguration; Motor fault | Check control wiring; Review drive parameters; Inspect motor for issues. |
| Guasto di sovracorrente | Sovraccarico del motore; Cortocircuito nel motore/cavi; Tempo di accelerazione errato | Reduce load; Check motor and cables; Increase acceleration time. |
| Sovravoltage colpa | Alto volume di ingressotage; Frenata rigenerativa senza resistenza di frenatura | Verificare il volume immessotage; Install braking resistor if needed. |
For detailed fault codes and advanced troubleshooting, refer to the complete technical manual available on the ABB website or contact ABB technical support.
7. Specifiche
Key technical specifications for the ABB ACS580-01-026A-4 Drive:
- Numero modello: ACS580-01-026A 4
- Marca: FIGURA
- Ingresso volumetage: 400 V CA
- Potenza nominale: 11 kW
- Valutazione attuale: 25 Amps
- Grado di protezione IP: Grado di protezione IP21
- Dimensioni della cornice: R2
- Tipo di montaggio: Montaggio su guida DIN
- Produttore: Azionamenti ABB
8. Garanzia e supporto
This ABB drive comes with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official ABB websito.
For technical support, service, or spare parts, please contact your local ABB representative or visit the ABB support portal: