Hager CFC225P

Hager CFC225P Residual Current Device (RCD)

Manuale di istruzioni

1. Introduzione

This manual provides essential information for the safe installation, operation, and maintenance of the Hager CFC225P Residual Current Device (RCD). Please read this manual thoroughly before installation or use and retain it for future reference. This device is designed to protect against electric shock by detecting earth leakage currents and rapidly disconnecting the supply.

2. Informazioni sulla sicurezza

AVVERTIMENTO: Electrical installation and maintenance should only be performed by qualified and competent persons in accordance with national wiring regulations and local safety standards. Failure to comply with these instructions may result in electric shock, fire, serious injury, or death.

3. Prodotto finitoview

Hager CFC225P Residual Current Device (RCD)

Figure 1: Hager CFC225P Residual Current Device.

This image shows the Hager CFC225P Residual Current Device. It is a compact, white electrical module designed for DIN rail mounting, featuring screw terminals for wiring connections at the top and bottom. The front panel clearly displays the model number 'CFC 225P', the brand 'hager', and key electrical ratings '25 A / IΔn 0,3 A', indicating a rated current of 25 Amperes and a residual operating current of 300 milliamperes. A prominent blue test button, marked with a 'T', is visible, along with a grey toggle switch for manual operation (ON/OFF). A small green indicator window is present below the model number, indicating the device's status. A clear plastic cover protects the lower part of the switch mechanism. Markings 'N' and '3' are visible near the top terminals, and 'N' and '4' near the bottom terminals, indicating neutral and phase connections respectively, essential for correct wiring.

The CFC225P is a 2-pole, Type AC RCD, suitable for detecting sinusoidal alternating residual currents. It is designed for use in domestic, commercial, and industrial installations to provide protection against indirect contact and additional protection against direct contact.

4. Configurazione e installazione

4.1 Controlli pre-installazione

4.2 Montaggio

The Hager CFC225P is designed for mounting on a standard 35mm DIN rail within an electrical enclosure or consumer unit. Simply clip the device onto the DIN rail until it is securely seated.

4.3 Cablaggio

Refer to the wiring diagram on the device and ensure correct polarity. The terminals are clearly marked:

5. Istruzioni per l'uso

5.1 Accensione/Spegnimento

5.2 Funzione di test

The RCD is equipped with a test button to verify its operational integrity. This test should be performed regularly to ensure the device is functioning correctly.

6. Manutenzione

The Hager CFC225P RCD requires minimal maintenance. However, regular checks are crucial for continued safety.

7. Risoluzione Dei Problemi

If your RCD trips frequently or fails to operate correctly, consider the following:

ProblemaPossibile causaSoluzione
RCD trips frequently.Earth fault in connected appliance/circuit; faulty appliance; dampness; insulation breakdown.Disconnect all appliances from the circuit. Reset the RCD. If it holds, reconnect appliances one by one to identify the faulty one. Check for dampness or damaged wiring. Consult an electrician if the issue persists.
RCD does not trip when test button is pressed.Internal fault in the RCD; no power to the RCD.Ensure power is supplied to the RCD. If power is present and it still doesn't trip, the RCD is faulty and must be replaced by a qualified electrician.
RCD cannot be switched ON.Persistent earth fault; RCD is already tripped and needs full reset; internal damage.Ensure the toggle switch is pushed fully down before attempting to switch ON. Check for persistent earth faults in the circuit. If the problem persists, consult a qualified electrician.

If you are unable to resolve an issue, always contact a qualified electrician for assistance. Do not attempt repairs yourself.

8. Specifiche

ParametroValore
ModelloCFC225P
MarcaHager
TipoAC (corrente alternata)
Poli2P (2 poli)
Corrente nominale (In)25 A
Corrente residua nominale di funzionamento (IΔn)300 mA (0.3 A)
Volume nominaletage(Ue)230/400 V CA
MontaggioGuida DIN (35 mm)
StandardNorma EN 61008-1
ASINB07Y6S71G5
Data prima disponibilità23 settembre 2019
ProduttoreHAGER
Paese di origineFrancia
Barcode (EAN)3250611613237

9. Garanzia

Hager products are manufactured to high standards and come with a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product type. Please refer to the official Hager website or contact your local Hager distributor for detailed warranty information.

10. Supporto

For technical assistance, product inquiries, or support, please visit the official Hager website or contact their customer service department. Contact details can typically be found on the Hager website under 'Contact Us' or 'Support'.

Hager Group Official Websito: www.hager.com

Documenti correlati - CFC225P

Preview Interruttore differenziale Hager RCBO con neutro commutato (6-32 A) - Guida all'installazione e al funzionamento
Questo documento fornisce istruzioni per l'installazione e il funzionamento dell'interruttore differenziale Hager (RCBO) con neutro commutato, coprendo i modelli da 6 a 32 Amperes. Descrive dettagliatamente i collegamenti elettrici, il montaggio, i test e le note applicative specifiche per EVCS.
Preview Hager ADC932R RCBO: Guida all'installazione e all'uso
Questa guida fornisce informazioni essenziali per l'installazione e l'utilizzo dell'interruttore differenziale (RCBO) Hager ADC932R con neutro commutato. ...
Preview Manuale di installazione e guida RCBO Hager
Guida completa per l'installazione e l'utilizzo degli interruttori differenziali Hager (RCBO), inclusi collegamenti elettrici, montaggio, collaudo e indicazioni specifiche per le applicazioni EVCS.
Preview Interruttore di sicurezza Hager (RCCB) 25-100A: Guida all'installazione e all'uso
Guida completa agli interruttori di sicurezza (RCCB) Hager da 25 a 100 A, che comprende installazione, collegamenti elettrici, istruzioni di sicurezza e indicatori di funzionamento. Include specifiche tecniche e note d'uso per elettricisti.
Preview Guida all'installazione e alla sicurezza degli interruttori differenziali Hager RCBO 6-50A
Questo documento fornisce istruzioni di installazione e avvertenze di sicurezza per gli interruttori differenziali Hager RCBO 6-50A. Descrive inoltre informazioni sulla garanzia, schemi elettrici e procedure operative per installatori qualificati.
Preview Note guida all'installazione dell'unità di consumo AFDD di Hager per RCBO e MCB
Comprehensive installation guidance notes from Hager for Consumer Unit AFDD Single Mod, covering RCBO and MCB devices, switch disconnectors, and dual RCCB units. Includes retrofitting information and rating derating guidelines for electrical installations.