Trane VAL12000

Trane VAL12000 OEM Thermostatic Expansion Valve

Modello: VAL12000 / VAL-12000

Marca: Trane

1. Prodotto finitoview

The Trane VAL12000 / VAL-12000 is an Original Equipment Manufacturer (OEM) thermostatic expansion valve designed for use in various Trane chiller systems. This component plays a crucial role in the refrigeration cycle by controlling the amount of refrigerant flowing into the evaporator, ensuring efficient heat exchange and system performance.

It is a direct replacement for or supersedes models VAL-12000, VAL012000, VAL08573, VAL-8573, and VAL8573.

Componente OEM Trane Stamp

Figure 1: Illustrative stamp indicating Trane OEM Component. Actual product appearance may vary.

Commonly Used In:

  • Various Trane Chillers: Rotary Chillers, RTAC Chillers, BCVC Chillers
  • Specific Rotary Chiller Models: RTAC120, RTAC135, RTAC140, and others.

2. Specifiche

ProduttoreTrane
Numero di parteVAL12000
Numero modello articoloVAL12000
Tipo di valvolaValvola di espansione termostatica (TXV)
Connessioni1.387 ODS (Outlet Diameter Size) x 2.125 OD (Overall Diameter); M12 Input
Peso dell'articoloCirca 5 libbre
Quantità del pacchetto dell'articolo1
ASINB07ZWHPJS6
Data prima disponibilità1 novembre 2019

Nota: le specifiche sono soggette a modifiche senza preavviso. Fare sempre riferimento all'etichetta del prodotto per informazioni più accurate.

3. Linee guida per l'installazione

Installation of the Trane VAL12000 expansion valve should only be performed by qualified HVAC technicians. Improper installation can lead to system malfunction, refrigerant leaks, and potential safety hazards. Always follow industry best practices and local codes.

3.1 Precauzioni di sicurezza

  • Ensure the system is de-energized and depressurized before beginning any work.
  • Wear appropriate Personal Protective Equipment (PPE), including safety glasses and gloves.
  • Handle refrigerants with care, following all safety guidelines.
  • Garantire un'adeguata ventilazione nell'area di lavoro.

3.2 Fasi di installazione (generali)

  1. Preparazione del sistema: Isolate the section of the refrigeration system where the valve is to be installed. Recover any refrigerant according to environmental regulations.
  2. Rimuovere la vecchia valvola: Carefully disconnect and remove the existing expansion valve, noting its orientation and connections.
  3. Preparare la nuova valvola: Inspect the new VAL12000 valve for any damage. Ensure all connection points are clean and free of debris.
  4. Valvola di collegamento: Install the new valve, ensuring proper alignment and secure connections. Use appropriate brazing or flaring techniques as required by the system design. Pay close attention to the M12 input and ODS connections.
  5. Thermal Bulb Placement: Securely attach the thermal bulb to the suction line in the correct location, typically just after the evaporator outlet, ensuring good thermal contact. Insulate the bulb to prevent ambient temperature interference.
  6. Controllo perdite: Dopo l'installazione, eseguire un controllo approfondito delle perdite utilizzando un metodo di rilevamento delle perdite appropriato.
  7. Evacuazione e ricarica: Evacuate the system to a deep vacuum to remove non-condensables and moisture. Recharge the system with the correct type and amount of refrigerant as specified by the chiller manufacturer.
  8. Avvio del sistema: Slowly bring the system back online and monitor its performance to ensure proper operation of the expansion valve.

For detailed, system-specific installation instructions, refer to the service manual of the Trane chiller unit in which this valve is being installed.

4. Funzionamento

The Trane VAL12000 is a thermostatic expansion valve (TXV) that automatically regulates the flow of liquid refrigerant into the evaporator based on the superheat of the refrigerant vapor leaving the evaporator. Its primary function is to maintain a constant superheat, ensuring the evaporator is fully utilized without allowing liquid refrigerant to return to the compressor.

The thermal bulb, sensing the temperature of the suction line, transmits pressure to the diaphragm within the valve. This pressure, balanced against the evaporator pressure and spring pressure, modulates the valve's opening. This dynamic control optimizes system efficiency and protects the compressor from liquid slugging.

5. Manutenzione

The Trane VAL12000 expansion valve is a robust component designed for long-term reliability. While it generally requires minimal direct maintenance, its optimal performance is dependent on the overall health and cleanliness of the refrigeration system.

5.1 Pratiche consigliate

  • Pulizia del sistema: Ensure the refrigeration system remains free of contaminants (moisture, acids, debris) which can cause corrosion or blockages within the valve. Regular filter dryer replacement is crucial.
  • Refrigerant Quality: Use only the specified type and quality of refrigerant.
  • Monitoraggio delle prestazioni: Periodically monitor system superheat and subcooling. Deviations can indicate issues with the expansion valve or other system components.
  • Rilevamento perdite: Regularly check for refrigerant leaks around valve connections.

Any adjustments or repairs to the expansion valve or refrigeration system should be performed by certified HVAC professionals.

6. Risoluzione Dei Problemi

Troubleshooting issues related to an expansion valve often involves diagnosing overall system performance. The following are common symptoms that might indicate an issue with the expansion valve, though they can also be caused by other system components.

SintomoPossible Cause (Valve Related)Azione
Elevato surriscaldamento / bassa pressione di aspirazioneValve restricted or stuck closed; thermal bulb lost charge or improperly installed.Check thermal bulb contact and insulation. Inspect valve for blockages. Consider valve replacement if faulty.
Low Superheat / High Suction Pressure (Flooding)Valve stuck open; thermal bulb improperly installed or sensing incorrect temperature.Verify thermal bulb placement. Check for external bulb damage. Consider valve replacement if faulty.
Fluctuating Suction Pressure / SuperheatIntermittent valve operation; moisture in system causing ice formation at valve orifice.Check for system contaminants. Replace filter dryer. Evacuate and recharge system.
Compressor Short CyclingImproper refrigerant flow due to valve issue, leading to low pressure cutout.Diagnose refrigerant charge and valve operation.

Importante: Troubleshooting refrigeration systems requires specialized knowledge and tools. Always consult with or hire a qualified HVAC technician for diagnosis and repair.

7. Garanzia e supporto

As an OEM component, the Trane VAL12000 expansion valve is typically covered under the warranty terms provided by Trane for their chiller systems or by the distributor from whom it was purchased. Specific warranty details, including duration and coverage, may vary.

For warranty claims, technical support, or to order replacement parts (such as MOD02686 for a stepper motor or MOD02688 for a cable, if applicable to your system), please contact your authorized Trane distributor or a certified HVAC service provider.

Produttore: Trane

Contatto: Refer to your local Trane representative or the official Trane website for service and support information.

Documenti correlati - VAL12000

Preview Istruzioni per l'installazione del kit del programma di manutenzione Trane RTWD/RTUD R'newal
Istruzioni di installazione per il kit del programma di assistenza Trane R'newal per refrigeratori RTWD e RTUD, che specificano la posizione dei componenti, le avvertenze di sicurezza, le problematiche ambientali e i guasti dei componenti.
Preview Catalogo completo di progettazione di sistemi ad acqua refrigerata Trane
Catalogo completo di Trane per la progettazione di sistemi avanzati ad acqua refrigerata. Questa guida descrive in dettaglio i componenti del sistema, i principi di progettazione all'avanguardia, le configurazioni e i criteri di selezione per refrigeratori, torri di raffreddamento, pompe e valvole di controllo. Si concentra sul raggiungimento di efficienza, affidabilità ed economicità nelle applicazioni HVAC commerciali e industriali, includendo approfondimenti su Tracer Chiller Plant Control e Trane Design Assist.
Preview Istruzioni per l'installazione retrofit Trane AFDR per refrigeratori RTHD
Guida completa all'installazione del convertitore di frequenza adattivo Trane AFDR Retrofit Air-cooled Adaptive Frequency Drive™ per refrigeratori RTHD. ...
Preview Istruzioni di installazione dell'accenditore Trane KIT03033USA
Istruzioni di installazione dettagliate per Trane Ignitor KIT03033USA, che comprendono avvertenze di sicurezza, considerazioni ambientali e procedure dettagliate per personale qualificato.
Preview Guida di riferimento rapido del sensore di comunicazione wireless Trane Air-Fi™ (WCS)
Questa guida fornisce informazioni di riferimento rapido sul sensore di comunicazione wireless Trane Air-Fi™ (WCS), spiegando nel dettaglio come regolare la temperatura ambiente, le impostazioni di sistema, la velocità della ventola, gestire la presenza e comprendere i codici di errore. Include avvisi di sicurezza e indicatori di durata della batteria.
Preview Trane Building Automation System (BAS) and HVAC Components Price List
Comprehensive price list for Trane Building Automation Systems (BAS), HVAC equipment, and related components, including controllers, sensors, chillers, air handlers, and accessories. Details product codes, model numbers, and pricing for commercial and industrial applications.