Wilo 4190420

Wilo Star S 33 FC Circulating Pump User Manual

Modello: 4190420

1. Introduzione

The Wilo Star S 33 FC 4190420 is a three-speed hydronic radiant floor circulating pump designed for efficient water circulation in various heating applications. Its robust cast iron housing and built-in motor protection ensure long life and reliable performance. This pump is suitable for closed-loop radiant heating, snow melting systems, baseboard, radiator, and fan coil heating applications.

Le caratteristiche principali includono:

2. Informazioni sulla sicurezza

AVVERTIMENTO: To reduce the risk of electric shock, consult the instruction manual for proper installation and operation. Always disconnect power before servicing the pump.

ATTENZIONE: The pump surface can become CALDO during operation. Avoid direct contact to prevent burns. Allow the pump to cool before handling or performing maintenance.

3. Prodotto finitoview e componenti

Wilo Star S 33 FC Circulating Pump, green cast iron body with black electrical box and control dial.

Figure 1: Wilo Star S 33 FC Circulating Pump. This image shows the main body of the pump, its electrical connection box, and the speed selection dial. The green cast iron housing is visible, along with the product label detailing specifications and warnings.

The Wilo Star S 33 FC pump consists of several key components:

4. Installazione e configurazione

Proper installation is crucial for the pump's performance and longevity. Refer to local plumbing and electrical codes.

  1. Montaggio: Securely mount the pump using its fixed flanges in the designated location within your hydronic system. Ensure the pump is installed in a horizontal position with the motor shaft horizontal to prevent air pockets.
  2. Collegamenti idraulici: Connect the system piping to the pump's flanges. Use the provided gaskets (O-rings) to ensure a watertight seal. Avoid overtightening connections.
  3. Cavi elettrici:
    • Prima di procedere al cablaggio, assicurarsi che l'alimentazione sia scollegata.
    • Connect the pump to a 115-Volt (AC), 60Hz power supply. The pump draws a maximum of 1.5A.
    • Follow the wiring diagram provided inside the electrical connection box.
    • Garantire una messa a terra adeguata per evitare rischi elettrici.
  4. System Filling and Purging: After installation, fill the hydronic system with water and thoroughly purge any air from the system. Air in the system can cause noise and reduce pump efficiency.

5. Istruzioni per l'uso

The Wilo Star S 33 FC features a three-speed motor, allowing you to adjust the pump's performance to match your system's requirements.

  1. Accensione: Once installed and the system is filled, restore power to the pump.
  2. Selezione della velocità: Locate the speed selection dial on the front of the pump (refer to Figure 1). The dial has settings for "max", "3", "2", "1", and "eco".
    • Velocità 3 (massima): Provides the highest flow rate and pressure. Power consumption is approximately 202W.
    • Velocità 2: Medium flow rate and pressure. Power consumption is approximately 143W.
    • Velocità 1 (Eco): Lowest flow rate and pressure, designed for energy efficiency. Power consumption is approximately 98W.
    Rotate the dial to select the desired speed setting. The optimal speed depends on your specific heating system's design and heat load requirements. Start with a lower speed and increase if insufficient circulation is observed.
  3. Valvola di ritegno: The built-in check valve can be removed if not required by your system design. Consult your HVAC professional if unsure.

6. Manutenzione

The Wilo Star S 33 FC pump is designed for minimal maintenance. However, periodic checks can ensure optimal performance and extend its lifespan.

7. Risoluzione Dei Problemi

Per i problemi più comuni e le possibili soluzioni, fare riferimento alla tabella seguente.

ProblemaPossibile causaSoluzione
La pompa non si avviaNessuna alimentazione; sovraccarico del motore; girante bloccata.Check power connection and circuit breaker; Allow motor to cool; Disconnect power and check for obstructions in impeller.
Flusso insufficienteAir in system; Incorrect speed setting; Clogged filter/piping.Purge air from system; Increase speed setting; Check and clean filters or piping.
Funzionamento rumorosoAir in system; Cavitation; Loose mounting.Purge air from system; Ensure adequate system pressure; Check mounting bolts for tightness.
La pompa perdeLoose connections; Damaged gaskets/seals.Tighten connections; Replace gaskets or seals.

If the problem persists after attempting these solutions, contact a qualified service technician or Wilo customer support.

8. Specifiche

AttributoDettaglio
Numero di modello4190420
MarcaVillo
MaterialeGhisa
Voltage115 Volt (CA)
FrequenzaFrequenza 60 Hz
Assorbimento di corrente massimo1.5 Amps
Power Consumption (Speed 3)202 Watt
Power Consumption (Speed 2)143 Watt
Power Consumption (Speed 1/Eco)98 Watt
Peso dell'articolo9.46 libbre (4.3 chilogrammi)
Dimensioni del pacco7.4 x 7.24 x 5.12 pollici
Classe di custodiaAllegato CSA 2
Classe di isolamentoClasse F
Massimo Temperatura dell'acqua230°F (110°C)
Pressione massima di esercizio145 PSI (10 bar)
CertificazioniCertificato UL/CSA

9. Garanzia e supporto

Wilo products are manufactured to high standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Wilo websito.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Wilo customer service. Contact information can typically be found on the Wilo websito o sulla ricevuta d'acquisto.

Funzionario Wilo Websito: www.wilo.com

Documenti correlati - 4190420

Preview Istruzioni per l'installazione e l'uso di Wilo-Star RS, RSD, ST, RSG, AC
Guida completa per l'installazione, il funzionamento e la manutenzione delle pompe di circolazione Wilo-Star RS, RSD, ST, RSG e AC. Include informazioni su sicurezza, specifiche tecniche, montaggio, collegamento elettrico, funzionamento, risoluzione dei problemi e ricambi.
Preview Istruzioni per l'installazione e l'uso della pompa di circolazione Wilo-Star RS, RSD, ST, RSG, AC
Istruzioni complete di installazione e funzionamento per le pompe di circolazione Wilo-Star serie RS, RSD, ST, RSG e AC. Include informazioni generali, norme di sicurezza, trasporto, stoccaggio, descrizione della pompa, accessori, montaggio, collegamento elettrico, funzionamento, manutenzione, risoluzione dei problemi e ricambi.
Preview Istruzioni per l'installazione e l'uso della pompa di circolazione Wilo-Star RS, RSD, ST, RSG, AC
Istruzioni complete di installazione e funzionamento per le pompe di circolazione Wilo-Star RS, RSD, ST, RSG, AC, che coprono informazioni generali, sicurezza, trasporto, descrizione, montaggio, installazione, collegamento elettrico, funzionamento, manutenzione e risoluzione dei problemi.
Preview Wilo-Yonos PICO: Istruzioni per l'installazione e l'uso
Guida rapida per l'installazione e il funzionamento della pompa di circolazione Wilo-Yonos PICO. ...
Preview Istruzioni di installazione e funzionamento Wilo-Star-Z 15
Questo documento fornisce istruzioni complete per l'installazione, il funzionamento e la manutenzione della pompa di circolazione Wilo-Star-Z 15. Include avvertenze di sicurezza, specifiche tecniche, uso previsto, procedure per la risoluzione dei problemi e informazioni di contatto per Wilo USA e Wilo Canada.
Preview Circolatori a rotore bagnato residenziali Wilo Star: istruzioni per l'installazione e l'uso
Istruzioni complete di installazione e funzionamento per i circolatori a rotore bagnato Wilo Star Residential. Riguardano sicurezza, dati tecnici, installazione, collegamento elettrico, avviamento, manutenzione e risoluzione dei problemi.