ICON 12422

Logo ICON

Manuale di istruzioni per il serbatoio di contenimento ICON 12422

Modello: 12422

1. Introduzione e oltreview

This manual provides detailed instructions for the installation, maintenance, and general use of the ICON 12422 Holding Tank. Proper installation and care are crucial for the longevity and optimal performance of your RV's waste water system. Please read all instructions carefully before beginning any work.

ICON 12422 Holding Tank

Figure 1: ICON 12422 Holding Tank, a 21 US Gallon capacity tank with a left end drain.

2. Configurazione e preinstallazione

2.1 Accessing the Tank

Before replacing or installing a new holding tank, it is often necessary to access the existing tank by disassembling the RV's underbelly. This process exposes all tank fittings, connections, and locations. For units with an outdoor kitchen, be aware that the shallow drain into the gray tank may be concealed, making it difficult to locate. Ensure all necessary cuts and disconnections are made before attempting to remove the tank.

Video 1: This video demonstrates the process of accessing the waste holding tanks by disassembling the RV's underbelly and disconnecting various components like vent pipes and toilet connections.

2.2 Measuring the Tank

Accurate measurements are essential for selecting the correct replacement tank. Measure the overall dimensions of the existing tank, including any flanges. ICON tanks typically feature a 1.25-inch flange. This tank measures approximately 70 inches long by 17.75 inches wide by 7 inches high.

Holding Tank Dimensions

Figure 2: Visual representation of the ICON 12422 Holding Tank with key dimensions highlighted.

2.3 Identifying Fittings

Each holding tank will have at least three fittings: a drain, at least one vent, and one or two inlets for sink/toilet water. This specific tank features four fittings: a drain, a vent, a sink inlet, and a shower inlet. It also includes four level sensors. Note the location and type of each fitting for proper replacement.

3. Installazione

3.1 Installing Fittings (Glue-in vs. Rubber Grommets)

There are two main types of fittings: glue-in and rubber grommets. For glue-in fittings, clean the area with acetone to remove grease. Apply Ebs polymer glue around the fitting and work it in with a slight spin. Allow 24 hours for the glue to cure.

For rubber grommets, drill the hole to the outside inner diameter (ID) of the inside part of the fitting to ensure a proper seal. Collapse the grommet and wedge it into the hole. Rotate it to allow the inside of the seal to seat properly. A little soap can help with insertion. There should be minimal side-to-side play once installed.

Tank Fitting Installation

Figura 3: primo piano view of tank fittings, demonstrating the secure installation of components.

3.2 Installing the Dump Valve

Apply Ebs glue to the dump valve, ensuring no glue gets inside the gate mechanism. Attach the dump valve to the fitting on the tank. Give it a slight twist to work the glue around and position it at a 90-degree angle if required by your setup. Allow it to set.

3.3 Connecting to Termination End

Once the hub is glued on, you have various options for connecting to the termination end, where your flexible hose will attach. Options include hub-to-hub connections or hub-to-spigot connections. ICON's ABS thermoform tanks have spigot ends, requiring a hub-to-hub connection when coming off the tank. The pipe size is the same as the spigot size. It is recommended to perform this step after the tank is already installed in the RV.

4. Specific Tank Considerations: Black Tank

The primary difference between a black tank and a gray tank in this application is the area where the toilet will mount. For black tanks, a glue-in threaded fitting is used for the toilet connection. For a 0.75-inch floor, use a threaded toilet flange. Apply pipe dope around it and thread it down until it is tight. For thicker floors (e.g., 2-inch or 2.25-inch), an adjustable fitting is available. Ensure the toilet flange bolts align perpendicularly with your toilet's orientation.

5. Operating the Holding Tank

Once installed, ensure all connections are secure and leak-free. Familiarize yourself with the location of the dump valve and the termination end for proper waste disposal. Regularly monitor the tank's level using the installed level sensors to prevent overfilling.

6. Manutenzione

Regular maintenance is key to extending the life of your holding tank and preventing odors or clogs. Flush the tank thoroughly after each use, especially the black tank. Use RV-specific tank treatments to break down waste and control odors. Periodically inspect all fittings and connections for any signs of leaks or wear.

7. Risoluzione Dei Problemi

If you experience issues such as slow draining, persistent odors, or inaccurate level readings, check for clogs in the drain lines or fittings. Ensure proper ventilation of the tank. For persistent issues, consult a qualified RV technician.

8. Specifiche

  • Modello: ICON 12422
  • Capacità: 21 galloni USA
  • Overall Dimensions (Including Flange): 70 cm L x 17.75 cm P x 7 cm A
  • Posizione di scarico: Left End Drain
  • Colore: Nero
  • Materiale: ABS Thermoform
  • raccordi: Drain, Vent, Sink Inlet, Shower Inlet
  • Level Sensors: 4
  • Codice UPC: 628423124228

9. Garanzia e supporto

For warranty information, technical support, or to purchase replacement parts, please visit the official ICON websito o contattare il servizio clienti. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.

Visit the ICON Store on Amazon

Documenti correlati - 12422

Preview ITC-250B Series Battery Powered Level Display: Instruction Manual & Specifications
This instruction manual provides detailed information on the ICON ITC-250B Series battery-powered level display, covering features, specifications, programming, ordering options, and wiring diagrams for industrial and process control applications.
Preview LevelPro ShoPro SP100 Level Display Controller Quick Start Manual
Quick start manual for the ICON LevelPro ShoPro SP100 Level Display Controller, providing installation, wiring, programming, and technical specifications for industrial applications. Includes safety information, features, model selection, and warranty details.
Preview Manuale di avvio rapido della serie LevelPro TVL: display e controller del livello del liquido
This quick start manual for the ICON LevelPro TVL Series provides essential guidance on setting up, operating, and programming the liquid level display and controller. Learn about its features, safety, wiring, and RS485 Modbus communication for industrial applications.
Preview Manuale di avvio rapido del pressostato digitale serie LevelPro® LPS50
Guida rapida per l'interruttore di pressione digitale ICON LevelPro® serie LPS50, che descrive in dettaglio sicurezza, specifiche, cablaggio, dimensioni e istruzioni di programmazione.
Preview ICON U44: Base audio 4x4 USB
È disponibile un supporto per l'interfaccia audio ICON U44. Scopri le funzioni, accessori, installazione e specifiche di questo dispositivo 4x4 USB 2.0 con ampio schermo, è stato eseguito il programma utilizzare iCON iO Pro.
Preview Scheda tecnica del trasmettitore del sensore di pH serie ICON ProCon P14G
Scheda tecnica dettagliata del trasmettitore del sensore di pH della serie ICON ProCon P14G, che copre caratteristiche, specifiche, installazione, cablaggio e selezione del modello per applicazioni di misurazione del pH industriale.