Leviton LB260-GS

Leviton 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker (LB260-GS) Instruction Manual

Model: LB260-GS

1. Introduzione

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.

The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.

2. Informazioni sulla sicurezza

WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • This product must be installed and serviced by qualified electrical personnel only.
  • Turn off all power to the electrical panel before working on or installing the circuit breaker.
  • Usa sempre un voltage detector to confirm power is off before touching any wires or components.
  • Rispettare tutti i codici e le normative elettriche locali e nazionali.
  • Non utilizzare questo dispositivo se sembra danneggiato.

La mancata osservanza di queste istruzioni può causare morte o lesioni gravi.

3. Prodotto finitoview

The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, front view

Immagine 3.1: Davanti view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, side view

Immagine 3.2: Lato view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, rear view showing bus connections

Immagine 3.3: Posteriore view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.

Caratteristiche principali:

  • Integrazione intelligente: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
  • Installazione semplice: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
  • Hydraulic Magnetic Technology: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
  • Maggiore sicurezza: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.

4. Configurazione e installazione

Professional installation by a qualified electrician is required.

  1. Preparare il centro di carico: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltagetester.
  2. Connessioni dei cavi: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
  3. Installare l'interruttore: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
  4. Filo di terra: Connect the ground wire from the branch circuit to the ground bar in the load center.
  5. Verifica installazione: Controllare attentamente tutti i collegamenti per verificarne la tenuta e il corretto posizionamento.
  6. Ripristina alimentazione: Una volta completata e verificata l'installazione, ripristinare l'alimentazione al centro di carico.

For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:

4.1 video: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.

5. Istruzioni per l'uso

Funzionamento manuale:

  • Accendere: Spingere con decisione la maniglia dell'interruttore in posizione "ON".
  • Spegnendo: Spingere con decisione la maniglia dell'interruttore in posizione "OFF".
  • Ripristino di un interruttore scattato: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.

GFCI Test and Reset:

The GFCI function should be tested monthly to ensure proper operation.

  1. Assicurarsi che l'interruttore sia in posizione "ON".
  2. Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
  3. To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
  4. If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.

Smart Features (My Leviton App):

The LB260-GS integrates with the My Leviton app, providing advanced functionality:

  • Monitoraggio energetico: View real-time and historical energy consumption data for the circuit.
  • Telecomando: Turn the breaker ON or OFF remotely via the app.
  • Notifiche: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
  • Test di autoverifica: The smart breaker performs self-tests and reports status to the app.

Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.

6. Manutenzione

  • Test GFCI mensile: Perform the GFCI test as described in Section 5.
  • Ispezione visiva: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
  • Pulizia: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.

7. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
L'interruttore scatta frequentemente.Sovraccarico, cortocircuito o guasto a terra.Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists.
Breaker does not reset after tripping.Persistent fault (overload, short circuit, or ground fault) or internal breaker damage.Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician.
Il pulsante di prova GFCI non fa scattare l'interruttore.Meccanismo GFCI difettoso.The breaker may be defective. It must be replaced by a qualified electrician.
No data in My Leviton app / Breaker not connecting.Network issue, app configuration error, or data hub issue.Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides.

For issues not covered here, contact Leviton customer support or a qualified electrician.

8. Specifiche

AttributoDettaglio
MarcaLevitone
Numero di modelloLB260-GS
Valutazione attuale60 Amps
Numero di poli2
Voltage120 / 240 VAC
Tipo di interruttoreGFCI (interruttore differenziale)
Trip TechnologyHydraulic Magnetic
Punteggio di interruzione10KA
Tipo di montaggioPanel Mounting (Plug-On)
Temperatura di esercizio-40°C a 85°C (-40°F a 185°F)
Dimensioni4 x 2.5 x 3.9 pollici (circa)
Peso13.6 once
Codice UPC078477815342

9. Garanzia e supporto

Garanzia:

Questo prodotto Leviton è coperto da una Garanzia limitata di 10 anni. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their websito o contattare l'assistenza clienti.

Assistenza clienti:

For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official websito o le informazioni di contatto fornite sulla confezione del prodotto.

You can visit the official Leviton website for more resources: www.leviton.com

Documenti correlati - LB260-GS

Preview Guida all'installazione della presa GFCI per montaggio su guida DIN Leviton GFNT1-DIN/GFNT2-DIN
Guida completa per l'installazione e il collaudo delle prese GFCI per montaggio su guida DIN GFNT1-DIN e GFNT2-DIN di Leviton, comprese istruzioni di cablaggio, precauzioni di sicurezza e risoluzione dei problemi.
Preview Manuale di installazione e funzionamento della presa GFCI Leviton con porte USB
Guida completa per l'installazione e il funzionamento delle prese GFCI Leviton con porte USB, comprese istruzioni di cablaggio, avvertenze di sicurezza, procedure di collaudo e informazioni sulla garanzia.
Preview Installazione e test della presa GFCI intelligente Leviton: una guida completa
Istruzioni dettagliate per l'installazione e il collaudo delle prese GFCI Leviton Smart (modelli D2GF1, D2GF2). Scopri di più sulla funzionalità GFCI, sul cablaggio, sulla risoluzione dei problemi e sulle precauzioni di sicurezza.
Preview Guida all'installazione e al collaudo della presa GFCI Leviton
Una guida completa su come installare e testare una presa GFCI Leviton SmartLock Pro, comprese istruzioni di cablaggio, precauzioni di sicurezza e suggerimenti per la risoluzione dei problemi.
Preview Guida all'installazione delle mappe di fase del centro di carico Leviton
Questa guida fornisce illustrazioni di mappa di fase per semplificare l'installazione del Leviton Whole Home Energy Monitor (LWHEM). Descrive inoltre dove terminare i cavi di alimentazione e montare i TA accessori Smart Mains Metering per il monitoraggio dei consumi energetici dell'intera abitazione.
Preview Istruzioni per l'installazione del contenitore del centro di carico Leviton
Istruzioni di installazione dettagliate per i contenitori per centri di carico Leviton, modelli LP2xx, LP3xx, LP4xx e LP6xx. ...