Sunco Lighting T8_BY_C-18W-6K-50PK

Manuale di istruzioni per lampadine a tubo LED Sunco T8 (modello T8_BY_C-18W-6K-50PK)

Brand: Sunco Lighting | Model: T8_BY_C-18W-6K-50PK

1. Introduzione

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Sunco T8 LED Tube Light Bulbs. Please read this manual thoroughly before installation and retain it for future reference.

Sunco T8 LED Tube Light Bulb with specifications printed on it

Image 1.1: Sunco T8 LED Tube Light Bulb. This image displays a single T8 LED tube, highlighting its design and printed specifications such as model number, wattage, and color temperature.

2. Informazioni sulla sicurezza

ATTENZIONE: Rischio di scossa elettrica. L'installazione richiede la conoscenza degli impianti elettrici degli apparecchi di illuminazione. Se non si è qualificati, non tentare l'installazione. Contattare un elettricista qualificato.

  • Always turn off power at the circuit breaker before installation, inspection, or removal.
  • These T8 LED tubes are Type B (Ballast Bypass) and require the removal of the existing ballast. Failure to remove the ballast and rewire the fixture correctly may damage the LED tube and create a serious fire hazard.
  • Garantire la fornitura voltage is compatible with the LED tubes (100-240V AC, 60Hz).
  • Do not use with dimmers unless explicitly stated as dimmable. These specific bulbs are non-dimmable.
  • Do not install in fixtures that are not designed for T8 LED tubes or that have incompatible lamp titolari.
  • Questo prodotto è destinato esclusivamente all'uso in ambienti interni.
  • Do not look directly at the operating LED light source.
  • UL certified for safety and performance.

3. Contenuto della confezione

La confezione contiene i seguenti articoli:

  • Sunco T8 LED Tube Light Bulbs (Quantity: 50)
  • Manuale di istruzioni (questo documento)
Fifty Sunco T8 LED Tube Light Bulbs

Image 3.1: A pack of 50 Sunco T8 LED Tube Light Bulbs. This image shows multiple LED tubes, representing the typical package quantity.

4. Specifiche

CaratteristicaSpecificazione
MarcaIlluminazione Sunco
Numero di modelloT8_BY_C-18W-6K-50PK
Tipo di luceGUIDATO
Forma della lampadina DimensioniT8
Lunghezza48 pollici (4 piedi)
Cosatage18 Watt
Luminosità2200 lumen
Temperatura del colore6000 Kelvin (Daylight Deluxe)
Base della lampadinaG13
Voltage100-240 Volt CA, 60 Hertz
Angolo del fascio160 gradi
MaterialeGlass (Clear Lens)
Vita media50,000 ore
CRI (indice di resa cromatica)50
Caratteristiche specialiInstant On, Ballast Bypass, Single Ended Power (SEP), T8/T10/T12 Compatible
CertificazioniUL, FCC, RoHS
Uso previstoIndoor (Garage, Workshop, Basement, Warehouse, Office)

5. Configurazione e installazione

These Sunco T8 LED tubes are Type B (Ballast Bypass) and require modification of your existing fluorescent fixture. This process involves removing the old ballast and rewiring the fixture to directly power the LED tubes. It is recommended that installation be performed by a qualified electrician.

5.1. Elenco di controllo pre-installazione

  • Verify power is OFF at the circuit breaker before starting.
  • Ensure the fixture is compatible with 4-foot T8 LED tubes.
  • Confirm you have the necessary tools: wire cutters, wire strippers, screwdriver, electrical tape, and wire nuts.

5.2. Ballast Removal and Rewiring (Single-Ended Power)

The Sunco T8 LED tubes are designed for Single-Ended Power (SEP), meaning power is supplied to one end of the tube only. This requires specific wiring modifications.

  1. Spegni l'alimentazione: Locate the circuit breaker controlling the fixture and switch it to the OFF position. Verify power is off using a voltagetester.
  2. Rimuovere i tubi fluorescenti esistenti: Rimuovere con cautela i vecchi tubi fluorescenti dall'apparecchio.
  3. Access Ballast: Open the fixture to expose the wiring and the ballast. The ballast is typically a rectangular box.
  4. Disconnect Ballast: Cut all wires connected to the ballast. Ensure no live wires remain connected to the ballast.
  5. Remove Ballast: Unscrew and remove the ballast from the fixture.
  6. Identify Live and Neutral Wires: Identify the main incoming Live (L) and Neutral (N) wires from the power supply.
  7. Rewire for Single-Ended Power:
    • Connect the incoming Live (L) wire to the pins on one end of the lamp holder (tombstone).
    • Connect the incoming Neutral (N) wire to the pins on the other end of the same lamp holder (tombstone).
    • For multiple tubes in the same fixture, ensure each tube's designated "power-in" end receives Live and Neutral connections. The other end of the tube should not be wired.
  8. Connessioni sicure: Use wire nuts to secure all connections and electrical tape to insulate any exposed wiring.
  9. Chiudi Apparecchio: Reassemble the fixture, ensuring all wiring is neatly tucked away and no wires are pinched.
  10. Installare tubi LED: Insert the Sunco T8 LED tubes into the lamp holders. Ensure the end marked for power input aligns with the rewired end of the fixture.
  11. Ripristina alimentazione: Riattivare l'alimentazione tramite l'interruttore automatico.
Ballast bypass wiring diagram for Type B LED tubes

Image 5.1: Ballast Bypass Wiring Diagram. This diagram illustrates how to remove the existing ballast and rewire the fixture for direct power to the LED tubes, showing Live (L) and Neutral (N) connections.

5.3. Tombstone Compatibility (Shunted vs. Non-Shunted)

For Single-Ended Power (SEP) Type B LED tubes, non-shunted tombstones are required. Shunted tombstones, commonly found in fixtures with instant-start ballasts, connect the two pins on one end of the lamp holder, which is incompatible with SEP LED tubes.

  • Shunted Tombstone: Both pin contacts are electrically connected internally. Not suitable for Single-Ended Power LED tubes.
  • Non-Shunted Tombstone: Each pin contact is isolated. Required for Single-Ended Power LED tubes, allowing separate Live and Neutral connections to the pins on the power-in end.
Diagram comparing shunted and non-shunted tombstones for LED tube installation

Image 5.2: Shunted vs. Non-Shunted Tombstones. This diagram visually explains the difference between shunted (not compatible with SEP) and non-shunted (compatible with SEP) tombstones, showing internal wiring paths.

If your existing fixture has shunted tombstones, they must be replaced with non-shunted tombstones for proper and safe operation of these LED tubes.

5.4. Video di installazione

Video 5.1: Oltreview | T8 LED Tube Clear 18W. This video provides a visual guide to the installation process for Sunco T8 LED tubes, including ballast bypass steps.

6. Istruzioni per l'uso

Once properly installed, operating your Sunco T8 LED Tube Light Bulbs is straightforward:

  • Accensione/spegnimento: Use the existing wall switch or fixture switch to turn the lights on or off.
  • Accensione immediata: These LED tubes provide instant illumination with no warm-up time or flickering.
  • Non dimmerabile: These specific LED tubes are non-dimmable. Do not connect them to dimmer switches.
Comparison of flicker-free LED lighting versus flickering traditional lighting

Image 6.1: Flicker-Free Lighting. This image demonstrates the stable, flicker-free light output of Sunco LED tubes compared to traditional flickering lights.

7. Manutenzione

Sunco T8 LED tubes are designed for long life and minimal maintenance. Follow these guidelines to ensure optimal performance:

  • Pulizia: Ensure power is off before cleaning. Use a soft, dry cloth to wipe the tubes. Do not use abrasive cleaners or solvents.
  • Ispezione: Periodically inspect the tubes and wiring for any signs of damage or loose connections. Address any issues promptly.
  • Sostituzione: With an average lifespan of 50,000 hours, these tubes require infrequent replacement. When replacement is necessary, ensure power is off and follow the installation steps in Section 5.

8. Risoluzione Dei Problemi

If you encounter issues with your Sunco T8 LED tubes, refer to the following troubleshooting guide:

ProblemaPossibile causaSoluzione
La luce non si accende.Nessuna alimentazione al dispositivo.
Cablaggio errato.
Collegamento allentato.
Defective tube.
Controllare l'interruttore.
Verificare il cablaggio secondo la Sezione 5.2.
Ensure tubes are securely seated.
Test with a known working tube.
Sfarfallio di luce.Ballast still present.
Collegamento allentato.
Interruttore dimmer incompatibile.
Ensure ballast is completely removed (Section 5.2).
Controllare tutti i collegamenti del cablaggio.
These tubes are non-dimmable; remove any dimmer switches.
La luce è fioca o incostante.Cablaggio errato.
Fluttuazioni di potenza.
Re-check wiring for proper Live/Neutral connections.
Consultare un elettricista per verificare la stabilità dell'alimentazione elettrica.
Tube makes buzzing noise.Ballast still present.Remove the ballast. Type B LED tubes do not use a ballast.

If troubleshooting steps do not resolve the issue, please contact Sunco Lighting customer support.

9. Garanzia e supporto

Sunco Lighting fornisce un Garanzia di 5 anno on these T8 LED Tube Light Bulbs, covering defects in materials and workmanship under normal use. This warranty is valid from the date of purchase.

For warranty claims, technical assistance, or any questions regarding your product, please contact Sunco Lighting customer support. Have your proof of purchase and model number ready.

  • Websito: www.suncolighting.com
  • Informazioni sui contatti: Refer to the Sunco Lighting website for the most current contact details (phone, email, support portal).

Documenti correlati - T8_BY_C-18W-6K-50PK

Preview Guida all'installazione del bypass dell'alimentatore per tubi LED T8 Sunco Lighting (tipo B)
Una guida completa all'installazione e al manuale per il ballast bypass per tubi LED T8 di Sunco Lighting (tipo B). Include semplici passaggi di installazione, specifiche e avvertenze importanti per un'installazione sicura e corretta.
Preview Guida all'installazione del cablaggio diretto LED T8 di Sunco Lighting
Istruzioni di installazione dettagliate per LED T8 Direct Wire di Sunco Lightingamps, che coprono il bypass della zavorra, le precauzioni di sicurezza e il cablaggio per l singoli e multipliamp infissi. Essenziali per elettricisti e facility manager.
Preview Istruzioni per l'installazione della lampada LED T8 Hybrid da 15 W
Comprehensive installation guide for Sunco Lighting's LED T8 Hybrid 15W tubes, covering both UL Type A (Plug & Go) and UL Type B (Direct Wire/Ballast Bypass) installation methods, including safety precautions and wiring diagrams.
Preview Manuale di installazione del pannello da soffitto a LED selezionabile Sunco Lighting 2x2
Guida completa all'installazione del pannello da soffitto a LED selezionabile Sunco Lighting 2x2 (PN22_DU-WH-4060K). Scopri come installare e cablare in sicurezza questo apparecchio a LED dimmerabile a risparmio energetico con watt selezionabile.tage e opzioni di temperatura del colore.
Preview Guida all'installazione del dispositivo di illuminazione a strisce LED Sunco Lighting da 4 piedi: cablaggio a estremità singola e doppia
Istruzioni di installazione per le strisce LED Sunco Lighting da 4 m, che illustrano il cablaggio a estremità singola e doppia, le avvertenze di sicurezza e le opzioni di montaggio. Questa guida è destinata a elettricisti qualificati.
Preview LED T8 Super Ibrido ULampIstruzioni per l'installazione
Guida completa all'installazione per LED T8 Super Hybrid UL di Sunco Lightingamps, che coprono sia i metodi di installazione di Tipo A (Plug & Go) che di Tipo B (Direct Wire). Include avvertenze di sicurezza, modalità operative e schemi elettrici.