Tektronix TBS2074B

Manuale utente dell'oscilloscopio digitale Tektronix TBS2074B

Model: TBS2074B | Brand: Tektronix

1. Introduzione

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Figura 1.1: Fronte view of the Tektronix TBS2074B Digital Oscilloscope.

2. Caratteristiche principali

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Impostazione

3.1 Disimballaggio

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Collegamento dell'alimentazione

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

Posteriore view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Accensione iniziale

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Funzionamento

4.1 Interfaccia utente terminataview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Misurazioni di base

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Funzioni avanzate

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Connettività

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Figura 5.1: primo piano view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Manutenzione

6.1 Pulizia

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Conservazione

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Risoluzione Dei Problemi

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

ProblemaPossibile causaSoluzione
Nessun potereCavo di alimentazione non collegato; Guasto alla presa di corrente; Fusibile interno bruciatoControllare il collegamento del cavo di alimentazione; testare la presa di corrente; contattare l'assistenza per la sostituzione del fusibile
Nessuna forma d'onda visualizzataProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Forma d'onda instabileIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Specifiche

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

SpecificazioneValore
ProduttoreTektronix
Numero di modelloTBS2074B
Larghezza di banda70 MHz (Upgradeable to 200 MHz with option)
Canali analogici4
Massimo S.ampla tariffa2 GS/s (half channel), 1 GS/s (all channels)
Lunghezza del record5 milioni di punti
Display9-inch WVGA Color Display
Misurazioni automatiche32 tipi
Interfaccia sondaTekVPI
ConnettivitàUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Peso dell'articolo3 chilogrammi
Dimensioni del paccoDimensioni: 50 x 40 x 26 cm
Componenti inclusiStandard Accessory KIT
Batterie utilizzateNO
Prima data disponibile (Amazon.co.jp)2020/5/11

9. Garanzia e supporto

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support

Documenti correlati - TBS2074B

Preview Guida in linea per l'oscilloscopio Tektronix serie 7 DPO Performance DPO714AX
Guida completa per l'oscilloscopio Tektronix DPO Performance serie 7, modello DPO714AX. Scopri le caratteristiche, il funzionamento, la configurazione e la risoluzione dei problemi di questo avanzato strumento di test e misurazione.
Preview Manuale di istruzioni dell'analizzatore di spettro Tektronix 7L12
Questo documento fornisce istruzioni complete per il funzionamento, il collaudo, la calibrazione e la manutenzione dell'analizzatore di spettro Tektronix 7L12, un'unità plug-in a doppia larghezza per gli oscilloscopi della serie 7000. Descrive in dettaglio le specifiche, i comandi del pannello frontale, le procedure operative, i metodi di calibrazione e le applicazioni per l'analisi dei segnali RF.
Preview Tektronix 5 Series B MSO: specifiche e verifica delle prestazioni
Specifiche dettagliate e procedure di verifica delle prestazioni per gli oscilloscopi MSO Tektronix Serie 5 B, inclusi i modelli MS054B, MS056B e MS058B. Dati tecnici essenziali per ingegneri e tecnici.
Preview Manuale di assistenza per oscilloscopio Tektronix 2235
Manuale di assistenza completo per l'oscilloscopio Tektronix 2235. Include specifiche dettagliate, istruzioni operative, teoria di funzionamento, controlli delle prestazioni, procedure di regolazione, manutenzione, risoluzione dei problemi ed elenchi dei componenti per personale di assistenza qualificato.
Preview Aiuto per l'oscilloscopio a dominio misto Tektronix serie 3 (MD032, MD034)
Manuale d'uso per l'oscilloscopio a dominio misto Tektronix serie 3 (MD032, MD034), che descrive in dettaglio le caratteristiche, il funzionamento, la configurazione e la risoluzione dei problemi di questo strumento avanzato di test e misurazione.
Preview Tektronix 3 Series MDO Oscilloscope MD032 & MD034: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 3 Series Mixed Domain Oscilloscopes (MDO32 and MDO34), covering analog and digital channel performance, acquisition systems, trigger capabilities, and more.