KAIWEETS HT206D

KAIWEETS HT206D Digitale Clamp Meter & KET01 Test Leads Kit User Manual

Modello: HT206D

1. Introduzione

Thank you for choosing the KAIWEETS HT206D Digital Clamp Meter and KET01 Soft Silicone Electrician Test Leads Kit. This comprehensive bundle provides accurate and reliable measurements for various electrical parameters, suitable for professional electricians, laboratories, factories, and household use. This manual will guide you through the proper setup, operation, maintenance, and troubleshooting of your device.

The HT206D clamp meter is a True-RMS device capable of measuring AC/DC Current, AC/DC Voltage, Frequency, Resistance, Capacitance, Diode, Continuity, and Temperature. It features LowZ and LPF functions for enhanced accuracy. The KET01 test leads are designed for safety and durability, made from soft silicone with CAT III 1000V & CAT IV 600V ratings.

2. Informazioni sulla sicurezza

Rispettare sempre le precauzioni di sicurezza quando si utilizzano apparecchiature di prova elettriche. La mancata osservanza di queste precauzioni può causare lesioni o danni al misuratore o all'apparecchiatura sottoposta a prova.

  • Non superare i limiti massimi di input per nessuna funzione.
  • Prestare attenzione quando si lavora con voltagsuperiori a 30 V CA RMS, 42 V di picco o 60 V CC. Questi voltagrappresentano un rischio di scossa elettrica.
  • Scollegare sempre l'alimentazione dal circuito prima di effettuare misurazioni di resistenza, capacità o diodi.
  • Assicurarsi che i puntali siano in buone condizioni, senza crepe o danni all'isolamento.
  • Non utilizzare il misuratore se appare danneggiato o se la custodia è aperta.
  • Utilizzare sempre la funzione e l'intervallo corretti per le misurazioni.
  • Quando si misura la corrente con il clamp, assicurarsi che solo un conduttore sia all'interno del clamp mascella.
Safety specifications for test probes, alligator clips, and extension leads
Figura 2.1: Safety specifications for various test lead components, including test probes (CAT III 1000V 10A), alligator clips (CAT III 300V 15A), plunger mini-hooks (CAT I 300V 3A), and test extension leads (CAT III 1000V 10A, CAT IV 600V 10A).

3. Prodotto finitoview e componenti

Il KAIWEETS HT206D Digital Clamp Meter and KET01 Test Leads Kit includes the main clamp meter unit, a pair of soft silicone test leads, alligator clips, and a K-type thermocouple for temperature measurements.

KAIWEETS HT206D Digitale Clamp Meter with included test leads, alligator clips, and temperature probe
Figura 3.1: Sopraview of the KAIWEETS HT206D Digital Clamp Meter and its accessories, including the main unit, red and black test leads, alligator clips, and a temperature probe.

3.1. Caratteristiche principali

  • Misurazione del vero valore efficace: Provides accurate readings for non-linear loads.
  • Ampia gamma di misurazioni: Up to 600A AC/DC Current, 600V AC/DC Voltage, 100mF Capacitance.
  • LowZ (bassa impedenza): Helps prevent false readings from ghost voltages.
  • LPF (filtro passa basso): For accurate measurements of variable frequency drive signals.
  • NCV (Volume senza contattotage) Rilevamento: Rileva in modo sicuro la tensione CAtage senza contatto fisico.
  • Misura della temperatura: With included K-type thermocouple.
  • Visualizzazione di 6000 conteggi: Alta risoluzione per letture precise.
  • Durable Test Leads: KET01 soft silicone leads designed for flexibility and safety.
Key features of the KAIWEETS HT206D clamp meter including 600 Amps AC/DC Current, Celsius/Fahrenheit temperature, 600 Volts AC/DC Voltage, 100 mF Capacitance, 6000 Counts Display, LPF, LowZ, and NCV.
Figura 3.2: Visual representation of the HT206D's key measurement capabilities and features.

4. Impostazione

4.1. Installazione della batteria

The KAIWEETS HT206D is battery powered. Before first use, or when the low battery indicator appears, install or replace the batteries. Refer to the battery compartment on the back of the meter for specific battery type and orientation.

4.2. Collegamento dei puntali di prova

Per eseguire voltage, resistance, capacitance, diode, continuity, or temperature measurements, connect the test leads to the meter's input jacks.

  • Insert the red test lead into the 'VΩHzCAP' input jack.
  • Inserire il puntale di prova nero nel jack di ingresso 'COM' (comune).

For temperature measurements, connect the K-type thermocouple to the appropriate input jacks, ensuring correct polarity.

Close-up of KAIWEETS test leads showing the special plug design and the silicone material's flexibility.
Figura 4.1: The KET01 test leads feature a special plug design for secure contact and are made of durable silicone material, capable of withstanding significant force.

5. Istruzioni per l'uso

Turn the rotary dial to select the desired measurement function. Ensure the test leads are connected correctly for the chosen function.

5.1. Misurazione della corrente CA/CC (Clamp Funzione)

To measure current, rotate the dial to the '60A' or '600A' AC/DC current range. Open the clamp jaw and enclose only one conductor of the circuit. The display will show the current reading. For accurate AC current readings on non-linear loads, the True-RMS feature is active.

KAIWEETS HT206D clamp meter measuring current on an industrial electrical panel, demonstrating its industrial strength.
Figura 5.1: The HT206D clamp meter in use, measuring current in an industrial setting, highlighting its robust design.

5.2. Vol. AC/DCtage Misurazione

Select the 'V' (Voltage) function on the rotary dial. Connect the test leads in parallel to the circuit or component you wish to measure. The meter will automatically detect AC or DC voltage.

5.3. Resistance, Capacitance, Diode, Continuity

Select the 'Ω/CAP/Diode/Continuity' function. The meter will auto-range. For resistance, connect leads across the component. For capacitance, ensure the capacitor is discharged before connecting leads. For diode, connect leads across the diode. For continuity, the meter will beep if resistance is below a certain threshold.

5.4. Frequency or Duty Cycle

Select the 'Hz/%' function. Connect the test leads to the circuit to measure frequency or duty cycle.

5.5. Misurazione della temperatura

Select the '°C/°F' function. Connect the K-type thermocouple to the meter's input jacks. Place the thermocouple probe at the point where temperature needs to be measured. The display will show the temperature in Celsius or Fahrenheit.

KAIWEETS HT206D measuring temperature in various states: liquid, gas, and solid, using the K-type thermocouple.
Figura 5.2: Demonstrations of temperature measurement using the HT206D in liquid, gas, and solid environments.

5.6. LowZ (Low Impedance) Function

The LowZ function is designed to eliminate 'ghost voltages' which can cause false readings. When measuring voltage in circuits with induced voltages, select the LowZ setting to get a more accurate reading by providing a low impedance path.

5.7. LPF (Low Pass Filter) Function

The LPF function is crucial for accurate measurements on variable frequency drives (VFDs) and other noisy electrical environments. It filters out high-frequency noise, allowing the meter to measure the fundamental frequency of the signal more accurately.

Explanation of Low Pass Filter (LPF) function, showing how it improves accuracy for drive output measurements by filtering out high-frequency noise.
Figura 5.3: Illustration of the Low Pass Filter (LPF) function, demonstrating its effect on voltage readings by filtering out unwanted frequencies.

5.8. NCV (Volume senza contattotage) Rilevamento

La funzione NCV consente il rilevamento sicuro della tensione CAtage without direct contact. Press the NCV button (located on the right side of the meter) and move the meter close to the conductor. The meter will indicate the presence of AC voltage through audible beeps and visual indicators.

5.9. Funzione di conservazione dei dati

To freeze the current reading on the display, short press the 'HOLD' button. Press it again to release the hold and resume live readings.

Dimostrazione di NCV (Volume senza contatto)tage) detection by long-pressing the button and the Data Hold function by short-pressing the button.
Figura 5.4: How to use the NCV detection (long press) and Data Hold (short press) functions on the HT206D.

6. Manutenzione

6.1. Pulizia

Pulisci la custodia del misuratore con un pannoamp panno e detergente delicato. Non utilizzare abrasivi o solventi. Mantenere i terminali di ingresso liberi da sporco e umidità.

6.2. Sostituzione della batteria

When the battery indicator appears on the display, replace the batteries immediately to ensure accurate readings. Refer to the battery compartment on the back of the meter for instructions on opening and replacing batteries.

6.3. Test Lead Care

Inspect test leads for any damage, cuts, or frayed insulation before each use. Replace damaged leads immediately. Store leads neatly to prevent tangling and damage.

Hands using KAIWEETS test leads to work on a circuit board, demonstrating precision and usability.
Figura 6.1: Proper handling of test leads during electronic work, emphasizing care and precision.

7. Risoluzione Dei Problemi

Se il misuratore non funziona correttamente, verificare i seguenti problemi comuni:

  • Nessun display/Display debole: Check battery level and replace if necessary. Ensure batteries are inserted with correct polarity.
  • Letture errate: Ensure the correct function and range are selected. Verify test lead connections are secure and undamaged. Check for external interference.
  • Nessun segnale acustico di continuità: Ensure the circuit is de-energized. Check if the resistance is within the continuity threshold.
  • Clamp Meter Not Reading Current: Ensure only one conductor is inside the clamp jaw. Verify the AC/DC current function is selected.

If problems persist, contact KAIWEETS customer support.

8. Specifiche

SpecificazioneValore
MarcaKAIWEET - dolciumi
ModelloHT206D
Tipo di misurazioneMultimetro
Fonte di alimentazioneAlimentato a batteria
ColoreRosso, Nero
StileClamp Meter and Test Leads
Valutazione di sicurezzaCAT III 1000V & CAT IV 600V (for test leads)
Visualizza i conteggi6000 Conteggi
Gamma di corrente CA/CCFino a 600A
Volume AC/DCtage GammaFino a 600V
Intervallo di capacitàFino a 100 mF
Intervallo di temperatura-4°F ~ 1832°F (with K-type thermocouple)

9. Garanzia e supporto

KAIWEETS products are designed for reliability and performance. For warranty information or technical support, please refer to the official KAIWEETS webo contattare direttamente il servizio clienti. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.

Per ulteriore assistenza, visitare il Negozio KAIWEETS su Amazon.

Documenti correlati - HT206D

Preview KAIWEETS HT206D Digitale Clamp Manuale utente e specifiche del misuratore
Manuale utente completo per il cl digitale KAIWEETS HT206Damp misuratore. Include istruzioni dettagliate sul funzionamento, precauzioni di sicurezza, caratteristiche, specifiche e manutenzione per questo contatore AC/DC a gamma automatica T-RMS.amp metro.
Preview Manuale utente del kit di puntali di prova KAIWEETS
Manuale utente per il kit di puntali KAIWEETS KET01, che descrive in dettaglio specifiche, precauzioni, contenuti, procedure di collegamento, pulizia, manutenzione e informazioni sulla garanzia.
Preview KAIWEETS HT206D True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT206D True-RMS Digital Clamp Misuratore, sicurezza di copertura, prodotto finitoview, funzioni, istruzioni per l'uso, procedure di misurazione, specifiche, precisione, manutenzione e informazioni sulla garanzia.
Preview KAIWEETS HT206D True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT206D True-RMS Digital Clamp Misuratore. Scopri le sue caratteristiche, le informazioni sulla sicurezza, le istruzioni per l'uso e le specifiche per misurazioni elettriche accurate.
Preview Manuale utente del multimetro digitale KAIWEETS HT112B
Manuale utente per il multimetro digitale KAIWEETS HT112B True RMS 6000 conteggi, contenente istruzioni dettagliate sulla sicurezza, procedure operative, funzioni di misurazione, specifiche e informazioni sulla garanzia.
Preview Manuale utente del set di puntali KAIWEETS KET01 - Sicurezza, specifiche e utilizzo
Manuale utente completo per il set di puntali KAIWEETS KET01, che comprende istruzioni di sicurezza, contenuto della confezione, specifiche tecniche, pulizia, manutenzione e informazioni sulla garanzia. Include indicazioni sui livelli di misurazione e sui collegamenti.