1. Introduzione
Thank you for choosing the KAIWEETS HT206D Digital Clamp Meter and KET01 Soft Silicone Electrician Test Leads Kit. This comprehensive bundle provides accurate and reliable measurements for various electrical parameters, suitable for professional electricians, laboratories, factories, and household use. This manual will guide you through the proper setup, operation, maintenance, and troubleshooting of your device.
The HT206D clamp meter is a True-RMS device capable of measuring AC/DC Current, AC/DC Voltage, Frequency, Resistance, Capacitance, Diode, Continuity, and Temperature. It features LowZ and LPF functions for enhanced accuracy. The KET01 test leads are designed for safety and durability, made from soft silicone with CAT III 1000V & CAT IV 600V ratings.
2. Informazioni sulla sicurezza
Rispettare sempre le precauzioni di sicurezza quando si utilizzano apparecchiature di prova elettriche. La mancata osservanza di queste precauzioni può causare lesioni o danni al misuratore o all'apparecchiatura sottoposta a prova.
- Non superare i limiti massimi di input per nessuna funzione.
- Prestare attenzione quando si lavora con voltagsuperiori a 30 V CA RMS, 42 V di picco o 60 V CC. Questi voltagrappresentano un rischio di scossa elettrica.
- Scollegare sempre l'alimentazione dal circuito prima di effettuare misurazioni di resistenza, capacità o diodi.
- Assicurarsi che i puntali siano in buone condizioni, senza crepe o danni all'isolamento.
- Non utilizzare il misuratore se appare danneggiato o se la custodia è aperta.
- Utilizzare sempre la funzione e l'intervallo corretti per le misurazioni.
- Quando si misura la corrente con il clamp, assicurarsi che solo un conduttore sia all'interno del clamp mascella.

3. Prodotto finitoview e componenti
Il KAIWEETS HT206D Digital Clamp Meter and KET01 Test Leads Kit includes the main clamp meter unit, a pair of soft silicone test leads, alligator clips, and a K-type thermocouple for temperature measurements.

3.1. Caratteristiche principali
- Misurazione del vero valore efficace: Provides accurate readings for non-linear loads.
- Ampia gamma di misurazioni: Up to 600A AC/DC Current, 600V AC/DC Voltage, 100mF Capacitance.
- LowZ (bassa impedenza): Helps prevent false readings from ghost voltages.
- LPF (filtro passa basso): For accurate measurements of variable frequency drive signals.
- NCV (Volume senza contattotage) Rilevamento: Rileva in modo sicuro la tensione CAtage senza contatto fisico.
- Misura della temperatura: With included K-type thermocouple.
- Visualizzazione di 6000 conteggi: Alta risoluzione per letture precise.
- Durable Test Leads: KET01 soft silicone leads designed for flexibility and safety.

4. Impostazione
4.1. Installazione della batteria
The KAIWEETS HT206D is battery powered. Before first use, or when the low battery indicator appears, install or replace the batteries. Refer to the battery compartment on the back of the meter for specific battery type and orientation.
4.2. Collegamento dei puntali di prova
Per eseguire voltage, resistance, capacitance, diode, continuity, or temperature measurements, connect the test leads to the meter's input jacks.
- Insert the red test lead into the 'VΩHzCAP' input jack.
- Inserire il puntale di prova nero nel jack di ingresso 'COM' (comune).
For temperature measurements, connect the K-type thermocouple to the appropriate input jacks, ensuring correct polarity.

5. Istruzioni per l'uso
Turn the rotary dial to select the desired measurement function. Ensure the test leads are connected correctly for the chosen function.
5.1. Misurazione della corrente CA/CC (Clamp Funzione)
To measure current, rotate the dial to the '60A' or '600A' AC/DC current range. Open the clamp jaw and enclose only one conductor of the circuit. The display will show the current reading. For accurate AC current readings on non-linear loads, the True-RMS feature is active.

5.2. Vol. AC/DCtage Misurazione
Select the 'V' (Voltage) function on the rotary dial. Connect the test leads in parallel to the circuit or component you wish to measure. The meter will automatically detect AC or DC voltage.
5.3. Resistance, Capacitance, Diode, Continuity
Select the 'Ω/CAP/Diode/Continuity' function. The meter will auto-range. For resistance, connect leads across the component. For capacitance, ensure the capacitor is discharged before connecting leads. For diode, connect leads across the diode. For continuity, the meter will beep if resistance is below a certain threshold.
5.4. Frequency or Duty Cycle
Select the 'Hz/%' function. Connect the test leads to the circuit to measure frequency or duty cycle.
5.5. Misurazione della temperatura
Select the '°C/°F' function. Connect the K-type thermocouple to the meter's input jacks. Place the thermocouple probe at the point where temperature needs to be measured. The display will show the temperature in Celsius or Fahrenheit.

5.6. LowZ (Low Impedance) Function
The LowZ function is designed to eliminate 'ghost voltages' which can cause false readings. When measuring voltage in circuits with induced voltages, select the LowZ setting to get a more accurate reading by providing a low impedance path.
5.7. LPF (Low Pass Filter) Function
The LPF function is crucial for accurate measurements on variable frequency drives (VFDs) and other noisy electrical environments. It filters out high-frequency noise, allowing the meter to measure the fundamental frequency of the signal more accurately.

5.8. NCV (Volume senza contattotage) Rilevamento
La funzione NCV consente il rilevamento sicuro della tensione CAtage without direct contact. Press the NCV button (located on the right side of the meter) and move the meter close to the conductor. The meter will indicate the presence of AC voltage through audible beeps and visual indicators.
5.9. Funzione di conservazione dei dati
To freeze the current reading on the display, short press the 'HOLD' button. Press it again to release the hold and resume live readings.

6. Manutenzione
6.1. Pulizia
Pulisci la custodia del misuratore con un pannoamp panno e detergente delicato. Non utilizzare abrasivi o solventi. Mantenere i terminali di ingresso liberi da sporco e umidità.
6.2. Sostituzione della batteria
When the battery indicator appears on the display, replace the batteries immediately to ensure accurate readings. Refer to the battery compartment on the back of the meter for instructions on opening and replacing batteries.
6.3. Test Lead Care
Inspect test leads for any damage, cuts, or frayed insulation before each use. Replace damaged leads immediately. Store leads neatly to prevent tangling and damage.

7. Risoluzione Dei Problemi
Se il misuratore non funziona correttamente, verificare i seguenti problemi comuni:
- Nessun display/Display debole: Check battery level and replace if necessary. Ensure batteries are inserted with correct polarity.
- Letture errate: Ensure the correct function and range are selected. Verify test lead connections are secure and undamaged. Check for external interference.
- Nessun segnale acustico di continuità: Ensure the circuit is de-energized. Check if the resistance is within the continuity threshold.
- Clamp Meter Not Reading Current: Ensure only one conductor is inside the clamp jaw. Verify the AC/DC current function is selected.
If problems persist, contact KAIWEETS customer support.
8. Specifiche
| Specificazione | Valore |
|---|---|
| Marca | KAIWEET - dolciumi |
| Modello | HT206D |
| Tipo di misurazione | Multimetro |
| Fonte di alimentazione | Alimentato a batteria |
| Colore | Rosso, Nero |
| Stile | Clamp Meter and Test Leads |
| Valutazione di sicurezza | CAT III 1000V & CAT IV 600V (for test leads) |
| Visualizza i conteggi | 6000 Conteggi |
| Gamma di corrente CA/CC | Fino a 600A |
| Volume AC/DCtage Gamma | Fino a 600V |
| Intervallo di capacità | Fino a 100 mF |
| Intervallo di temperatura | -4°F ~ 1832°F (with K-type thermocouple) |
9. Garanzia e supporto
KAIWEETS products are designed for reliability and performance. For warranty information or technical support, please refer to the official KAIWEETS webo contattare direttamente il servizio clienti. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.