ATO B08CKD2PTS

Manuale utente della cella di carico a compressione ATO da 2 tonnellate

1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the ATO Compression Load Cell, 2 Ton. The ATO Compression Load Cell is a transducer designed to convert mechanical force into an electrical signal. It is widely used in industrial automation, weighing systems, force measurement, and control applications, providing accurate and reliable solutions for tension, compression, or multi-axis force measurement.

ATO Compression Load Cell, top-down view

Immagine 1.1: Dall'alto verso il basso view of the ATO Compression Load Cell, 2 Ton. This image shows the robust stainless steel construction and the central loading point.

2. Caratteristiche del prodotto

  • Materiale: Constructed from durable alloy steel or stainless steel for longevity and resistance to environmental factors.
  • Funzione: Specifically designed for precise weight measurement, offering good anti-eccentric load performance and a low-profile progetto.
  • Sigillatura: Features a fully sealed construction, enhancing durability and protection in various industrial environments.
  • Precisione: Achieves an accuracy of 0.03% F.S (Full Scale), encompassing linearity, hysteresis, and repeatability.
  • Classe di protezione: Rated IP67, indicating complete protection against dust ingress and temporary immersion in water.

3. Applicazioni

The ATO Compression Load Cell is suitable for a wide range of industrial applications requiring accurate force and weight measurement. Typical applications include:

  • Platform scales
  • Truck scales
  • Rail weighbridges
  • Material level measurement and control in warehouses
  • General force measurement systems

4. Configurazione e installazione

Proper installation is crucial for the accurate and reliable operation of the load cell. Ensure the mounting surface is flat, rigid, and capable of supporting the intended load.

4.1. Montaggio

Mount the load cell securely using appropriate fasteners through the designated mounting holes. Ensure the load is applied centrally and vertically to the load cell's sensing element to prevent eccentric loading, which can affect accuracy.

4.2. Cablaggio

Connect the load cell to your measurement system according to the wiring diagram below. Pay close attention to the polarity of the excitation and signal lines.

Wiring diagram for ATO Compression Load Cell

Image 4.1: Wiring diagram for the ATO Compression Load Cell. The diagram illustrates the connections for SIG-, SIG+, EXC-, and EXC+, along with the shielded wire.

The typical wiring configuration is as follows:

  • EXC+ (Excitation +): Filo rosso
  • EXC- (Excitation -): Filo nero
  • SIG+ (Signal +): Filo verde
  • SIG- (Signal -): Filo bianco
  • Shielded wire: Yellow wire (for grounding/noise reduction)

After wiring, ensure all connections are secure and properly insulated to prevent short circuits or signal interference.

5. Funzionamento

The ATO Compression Load Cell converts applied force into an electrical signal. To obtain readable measurements, the load cell must be connected to a compatible digital panel meter, transmitter, or data acquisition system.

  • Digital Panel Meter: Connect the load cell directly to a specialized digital panel meter to display force or weight readings.
  • Trasmettitore: Utilize a transmitter to convert the load cell's raw signal into standard industrial signals such as 0-5V, 0-10V, or 4-20mA. These signals can then be fed into PLCs (Programmable Logic Controllers), DCS (Distributed Control Systems), or other control systems.
  • Calibrazione: Perform system calibration according to the instructions of your connected display or control unit to ensure accurate measurements.

6. Manutenzione

The ATO Compression Load Cell is designed for robust industrial use and requires minimal maintenance. However, regular checks can help ensure its longevity and accuracy.

  • Pulizia: Keep the load cell and its surroundings clean from dust, debris, and corrosive substances. Use a soft, dry cloth for cleaning.
  • Ispezione: Periodically inspect the load cell for any signs of physical damage, corrosion, or loose connections.
  • Integrità del cavo: Ensure the connecting cable is free from cuts, abrasions, or kinks that could compromise signal integrity.
  • Ricalibrazione: Depending on the application and usage frequency, periodic recalibration may be necessary to maintain measurement accuracy.

7. Risoluzione Dei Problemi

If you encounter issues with your ATO Compression Load Cell, consider the following troubleshooting steps:

  • Nessuna lettura/lettura errata:
    • Verify all wiring connections are correct and secure, paying attention to polarity.
    • Check the power supply to the load cell and the connected display/control unit.
    • Ensure the load cell is properly mounted and the load is applied correctly without eccentric forces.
    • Confirm the display unit is calibrated correctly for the load cell's specifications.
  • Letture instabili:
    • Check for mechanical vibrations or instability in the mounting structure.
    • Inspect for electromagnetic interference (EMI) from nearby electrical equipment. Ensure proper shielding and grounding.
    • Verify the load cell is not overloaded or underloaded beyond its specified range.
  • Danni fisici: If the load cell shows signs of physical damage, it may need replacement. Do not attempt to repair damaged load cells.

If issues persist after performing these checks, please contact ATO customer support for further assistance.

8. Specifiche

The following table details the technical specifications of the ATO Compression Load Cell, 2 Ton.

SpecificazioneValore
MarcaATO
ModelloB08CKD2PTS
Capacità2 tonnellata (2000 kg)
MaterialeAcciaio inossidabile
Precisione0.03% F.S (Linearity + Hysteresis + Repeatability)
Classe di protezioneGrado di protezione IP67
Codice UPC783902770829
ProduttoreATO
Prima data disponibile8 luglio 2020

8.1. Dimensioni

Refer to the diagram and table below for the physical dimensions of the load cell.

Dimension diagram for ATO Compression Load Cell

Image 8.1: Detailed dimension diagram of the ATO Compression Load Cell, showing various measurements in millimeters.

CapacitàL1 (millimetro)L2 (millimetro)ΦC (mm)ΦD (mm)H (mm)E (millimetro)SR (mm)
300~1000 kg7462166.5413352
2 tonnellate9073208.553.54470

9. Supporto e garanzia

ATO is committed to providing high-quality products and customer satisfaction. If you have any questions or encounter an issue with your ATO Compression Load Cell, please do not hesitate to contact us.

  • Assistenza clienti: Our engineering team offers one-on-one support to help you select the best sensor for your needs and resolve any product-related inquiries. We aim to respond within 12 hours.
  • Garanzia: For specific warranty terms and conditions, please refer to the product packaging or contact ATO customer service directly.

Per maggiori informazioni e prodotti aggiuntivi, visita il ATO Store.

Documenti correlati - B08CKD2PTS

Preview ATO Load Cell Transmitter User Manual | ATO-LCTR-OA, ATO-LCTR-DY510
Comprehensive user manual for the ATO Load Cell Transmitter (ATO-LCTR-OA, ATO-LCTR-DY510). Learn about specifications, wiring, calibration, and features of this industrial weighing sensor and signal converter.
Preview Manuale utente della bilancia per gru digitale ATO | ATO-CRS-50T
Manuale utente completo per la bilancia digitale per gru ATO (modello ATO-CRS-50T), che illustra caratteristiche, specifiche, funzionamento, calibrazione e risoluzione dei problemi. Include dettagli sui modelli GSP911-30 e GSP911-50.
Preview Manuale utente e specifiche del misuratore di umidità ATO-TK100
Manuale utente e specifiche del misuratore di umidità digitale portatile ATO-TK100. Scopri le sue caratteristiche, il funzionamento e la manutenzione per la misurazione del contenuto di umidità in vari materiali.
Preview Guida rapida all'installazione e all'applicazione del VFD ATO
Una guida completa per l'impostazione e l'applicazione di azionamenti a frequenza variabile (VFD) ATO, che copre l'installazione rapida, le configurazioni dei parametri e varie modalità di controllo, tra cui il controllo del pannello, il sistema a tre fili, il controllo esterno, multi-stage operation, and constant pressure water supply systems.
Preview Manuale operativo dello spettrofotometro a reticolo ATO
Questo manuale operativo fornisce istruzioni dettagliate per lo spettrofotometro a reticolo ATO, che riguardano la descrizione dell'interfaccia, la calibrazione, le procedure di misurazione, la gestione dei dati, le impostazioni di sistema e le specifiche tecniche per un'analisi accurata del colore.
Preview Manuale utente del sensore di rumore industriale (tipo analogico) - SN-ZS-BZ-V03
Manuale utente per il sensore di rumore industriale ATO (tipo analogico), modello SN-ZS-BZ-V03. Dettagli sul prodottoview, caratteristiche, parametri principali, struttura del sistema, connessione hardware e conversione del segnale di uscita.