1. Introduzione
The ThruNite Archer 2A V3 is a compact and durable LED flashlight designed for versatile everyday use. Featuring a dual-switch interface, multiple brightness levels, and robust construction, it is suitable for various outdoor activities, emergency situations, and general illumination needs. This manual provides essential information for the proper setup, operation, and maintenance of your Archer 2A V3 flashlight.

Image 1: ThruNite Archer 2A V3 LED Flashlight, showcasing its sleek black aluminum body.
2. Contenuto della confezione
Si prega di controllare la confezione per verificare la presenza dei seguenti elementi:
- Archer 2A V3 flashlight x1
- Cordino x1
- Pocket clip x1
- O-ring di ricambio x2

Image 2: All items included in the ThruNite Archer 2A V3 package, laid out on a white background.
3. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Tipo di LED | XP-L2 LED |
| Uscita massima | 500 lumen |
| Distanza del raggio | 93 metri |
| Fonte di alimentazione | 2 x AA batteries (Alkaline, not rechargeable) |
| Materiale | Aerospace-grade aluminum body with military-grade Type III hard-anodized anti-abrasive finish |
| Resistenza all'acqua | IPX8 (sommergibile 2 metri) |
| Resistenza all'impatto | 1 metro |
| Dimensioni | 6.1"P x 0.87"L x 0.87"A |
| Peso | 1.69 once (senza batterie) |
The ThruNite Archer 2A V3 is designed for durability and performance, featuring a robust aluminum construction and an XP-L2 LED for efficient illumination.

Immagine 3: Primo piano view of the XP-L2 LED emitter, highlighting the orange peel reflector for a smooth beam.
4. Impostazione
4.1 Installazione della batteria
The Archer 2A V3 requires two AA batteries (not included). To install the batteries:
- Svitare il tappo posteriore della torcia.
- Insert two AA batteries with the positive (+) end facing towards the head of the flashlight.
- Riavvitare saldamente il tappo di coda per garantire un contatto adeguato e la resistenza all'acqua.
Ensure the batteries are inserted correctly according to polarity markings to prevent damage to the flashlight.

Image 4: The tail cap of the ThruNite Archer 2A V3, which unscrews for battery access.
Video 1: A demonstration of battery installation and the robust construction of the tail cap switch, highlighting the heavy-duty spring and solid contact point. The video also shows the O-ring for IPX8 waterproofing.
5. Istruzioni per l'uso
5.1 Accensione/spegnimento
- Momentary Activation: Press the tail cap halfway to momentarily activate the light.
- ON/OFF costante: Fully click the tail switch to turn the light on or off.
5.2 Selezione della modalità
When the light is on, use the side switch to cycle through the brightness modes:
- Modalità ciclo: Single press the side switch to rotate among Firefly, Low, Medium, and High modes.
- Modalità strobo: Long press the side switch to activate Strobe mode. Single press the side switch again to exit Strobe mode and return to the previously used brightness level.
5.3 Funzione di memoria della modalità
The Archer 2A V3 features a mode memory function. It will remember the last used brightness mode (Firefly, Low, Medium, or High) when turned off and will activate in that mode when turned back on. Strobe mode is not memorized.
5.4 Output and Runtime (using 2x AA Alkaline batteries)
| Modalità | Produzione | Durata |
|---|---|---|
| Lucciola | 0.2 lumen | 15 giorni |
| Basso | 17 lumen | 51 ore |
| Medio | 70 lumen | 11 ore |
| Alto | 500 Lumens (steps down to 280 Lumens after 3.3 minutes) | 3.3 Minutes + 2 Hours |
| Stroboscopio | 400 lumen | 2.25 ore |

Image 5: Illustration of the dual switch operation, showing the tail cap for ON/OFF and the side switch for mode changes.
Video 2: A short demonstration of the ThruNite Archer 2A V3's brightness levels and strobe function in a dark environment, showcasing la sua potente uscita.
Video 3: Night shot footage demonstrating the beam throw and illumination capabilities of the Archer 2A V3 in various modes, highlighting its effectiveness in dark conditions.
6. Manutenzione
- Pulizia: Clean the threads and O-rings regularly with a clean cloth.
- Lubrificazione: Applicare periodicamente uno strato sottile di grasso al silicone sugli O-ring per mantenerne la resistenza all'acqua.
- Sostituzione dell'O-ring: Replace worn O-rings with the provided spare O-rings to ensure the IPX8 waterproof rating.
- Cura della batteria: Remove batteries from the flashlight if it will not be used for an extended period to prevent battery leakage and potential damage.
Video 4: Una breve pre-produzioneview video demonstrating the IPX8 water resistance of the ThruNite Archer 2A V3 by submerging it in water while operating, confirming its waterproof capabilities.
7. Risoluzione Dei Problemi
- La luce non si accende:
- Check if the batteries are inserted correctly with the positive (+) end towards the head.
- Assicurarsi che il tappo di coda sia avvitato saldamente.
- Replace batteries with fresh ones if they are depleted.
- La luce tremola o si spegne inaspettatamente:
- Pulire i contatti e le filettature della batteria con un panno pulito.
- Assicurarsi che il cappuccio della coda sia completamente serrato.
- Controllare il livello di carica della batteria e sostituirla se necessario.
8. Garanzia e supporto
ThruNite offers a limited warranty for its products. For detailed warranty information, product support, or any issues not covered in this manual, please contact ThruNite customer service directly. Contact information can typically be found on the official ThruNite websito o tramite il tuo rivenditore.
Assistenza clienti: Please do not hesitate to contact us if you encounter any further problems with our products.